구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교
Which is the proper insertion method of laryngeal mask airway according to the rescuer’s position? : Comparison between index finger insertion and thumb insertion
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer’s position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer’s position.
Abstract
Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer’s position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer’s position.
참고문헌 (22)
- Isabel Barata, "The Laryngeal Mask Airway: Prehospital and Emergency Department Use", Emergency Medicine Clinics of North America, 26(4), pp.1069~1083 (2008), Elsevier BV[DOI]
- Brain AI., "Historical aspects and future directions", Int Anesthesiol Clin, 36(2), pp.1~18 (1998)
- 정중식, "서울시 119 구급대의 병원전 응급처치 적절성 평가", 대한응급의학회지, 19(3), pp.233~244 (2008), 대한응급의학회
- 황지영, "초보자에서 마네킨에게 직접 후두경과 삽관용 후두마스크기도기를 이용한 기관내삽관의 비교", 한국응급구조학회지, 16(2), pp.75~89 (2012), 사단법인 한국응급구조학회
- "LMA instruction for use" (2017)[URL]
- Monica Goyal, "Laryngeal mask airway insertion by classic and thumb insertion technique: a comparison", F1000Research, 2, pp.123~ (2013), F1000 Research, Ltd.[DOI]
- Davies PR, "Laryngeal mask airway and tracheal tube insertion by unskilled personnel", Lancet, 336(8721), pp.977~979 (1990)
- Räsänen J., "The laryngeal mask airway–first class on difficult airways", Finnanest Nro, 33(3), pp.302~305 (2000)
- Matta BF, "Laryngeal mask airway: a more successful method of insertion", J Clin Anesth, 7(2), pp.132~135 (1995)
- BABITA GHAI, "Laryngeal mask airway insertion in children: comparison between rotational, lateral and standard technique", Pediatric Anesthesia, 18(4), pp.308~312 (2008), Wiley-Blackwell[DOI]
- Benumof JL., "Laryngeal mask airway and the ASA difficult airway algorithm", Anesthesiology, 84(3), pp.686~699 (1996)
- Kim HJ, "A comparative easiness of blind orotracheal intubation using laryngeal mask airway with two different head positions", Korean J Anesthesiol, 39(4), pp.469~475 (2000)
- 손수창, "소아에서 전신마취 유도시 기관내 튜브와 후두 마스크사용에 따른 호흡역학의 비교", Korean Journal of Anesthesiology, 47(6), pp.772~778 (2004), 대한마취통증의학회
- 최혜경, "모형폐의 물리적 특성 변화에 따른 Bag-Valve-Mask의 사용방법 연구", 한국응급구조학회지, 17(3), pp.21~28 (2013), 사단법인 한국응급구조학회[DOI]
- 신소연, "RespiTrainer를 활용한 백-밸브마스크 환기에서 일회호흡량과 기도압 비교 연구", 한국화재소방학회 논문지, 28(6), pp.76~81 (2014), 한국화재소방학회[DOI]
- Cork RC, "Prospective comparison of use of the laryngeal mask and endotracheal tube for ambulatory surgery", Anesth Analg, 79(4), pp.719~727 (1994)
- Keller C, "Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients", Br J Anaesth, 82(2), pp.286~287 (1999)
- Keller C, "Influence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway", Br J Anaesth, 81(2), pp.186~187 (1998)
- Ocker H, "A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures", Anesth Analg, 95(4), pp.1094~1097 (2002)
- Korean emergency airway management society., "Manual of emergency airway management", pp.108~109 (2013), Koonja
- Brimacombe JR, "The incidence of aspiration associated with the laryngeal mask airway: a meta-analysis of published literature", J Clin Anesth, 7(4), pp.297~305 (1995)
- Asai T, "Cricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation", Br J Anaesth, 76(6), pp.772~776 (1996)