본문 바로가기
KERD
논문KCI 등재

Effectiveness of Solution with 5% Detergent for Cleaning Transnasal Esophagogastroduodenoscopy Lens

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Unsedated transnasal esophagogastroduodenoscopy (EGD) is affected by a poor scope lens-cleaning function. We have previously reported good, albeit limited, effects of an oolong tea washing solution; here, we evaluated the effectiveness of a 5%lens cleaning solution for cleaning an EGD lens. Methods: Five percent lens cleaning solution (C), 5% dimethicone solution (D), and distilled water (W) were prepared. Study I:Lenses were soiled with pork grease, washed with each washing solution, and their image quality was judged. Study II: Patients (n=996)scheduled for transnasal EGD were randomly assigned to the C- or W-group. Lens cleanliness level, washing solution volume used,and endoscopist stress due to lens contamination were determined. Results: Study I: The image quality of the lenses washed with (C) was significantly superior. (D) was clinically unsuitable because ofspray nozzle clogging. Study II: Lens cleaning in the C-group was significantly superior (p<0.0001) and the solution volume requiredwas significantly reduced (p<0.0001), while endoscopist stress was also lower (p<0.0001). Conclusions: For transnasal small-caliber EGD, the present 5% lens cleaning solution provided good visibility. It features a highdetergency level and is simple to formulate for therapeutic endoscopy applications, such as endoscopic submucosal dissection.

Abstract

Background/Aims: Unsedated transnasal esophagogastroduodenoscopy (EGD) is affected by a poor scope lens-cleaning function. We have previously reported good, albeit limited, effects of an oolong tea washing solution; here, we evaluated the effectiveness of a 5%lens cleaning solution for cleaning an EGD lens. Methods: Five percent lens cleaning solution (C), 5% dimethicone solution (D), and distilled water (W) were prepared. Study I:Lenses were soiled with pork grease, washed with each washing solution, and their image quality was judged. Study II: Patients (n=996)scheduled for transnasal EGD were randomly assigned to the C- or W-group. Lens cleanliness level, washing solution volume used,and endoscopist stress due to lens contamination were determined. Results: Study I: The image quality of the lenses washed with (C) was significantly superior. (D) was clinically unsuitable because ofspray nozzle clogging. Study II: Lens cleaning in the C-group was significantly superior (p<0.0001) and the solution volume requiredwas significantly reduced (p<0.0001), while endoscopist stress was also lower (p<0.0001). Conclusions: For transnasal small-caliber EGD, the present 5% lens cleaning solution provided good visibility. It features a highdetergency level and is simple to formulate for therapeutic endoscopy applications, such as endoscopic submucosal dissection.

참고문헌 (15)

  1. Yuki M, "Unsedated transnasal small-caliber esophagogastroduodenoscopy in elderly and bedridden patients", World J Gastroenterol, 15, pp.5586~5591 (2009)
  2. Yagi J, "A prospective randomized comparative study on the safety and tolerability of transnasal esophagogastroduodenoscopy", Endoscopy, 37, pp.1226~1231 (2005)
  3. Kawai T, "Comparison of the effects on cardiopulmonary function of ultrathin transnasal versus normal diameter transoral esophagogastroduodenoscopy in Japan", Hepatogastroenterology, 54, pp.770~774 (2007)
  4. Kobayashi Y, "Use of anticoagulant or antiplatelet agents is not related to epistaxis in patients undergoing transnasal endoscopy", Endosc Int Open, 6, pp.E104~E110 (2018)
  5. Stroppa I, "Unsedated transnasal versus transoral sedated upper gastrointestinal endoscopy : a one-series prospective study on safety and patient acceptability", Dig Liver Dis, 40, pp.767~775 (2008)
  6. Ai ZL, "Unsedated transnasal upper gastrointestinal endoscopy has favorable diagnostic effectiveness, cardiopulmonary safety, and patient satisfaction compared with conventional or sedated endoscopy", Surg Endosc, 26, pp.3565~3572 (2012)
  7. Komazawa Y, "Oolong tea is useful for lens cleansing in transnasal small-caliber esophagogastroduodenoscopy", Endoscopy, 42, pp.104~108 (2010)
  8. Tanuma T, "Current status of transnasal endoscopy worldwide using ultrathin videoscope for upper gastrointestinal tract", Dig Endosc, 28(Suppl 1), pp.25~31 (2016)
  9. Hayashi Y, "Comparison of the diagnostic utility of the ultrathin endoscope and the conventional endoscope in early gastric cancer screening", Dig Endosc, 21, pp.116~121 (2009)
  10. Horiuchi A, "Prospective comparison between sedated high-definition oral and unsedated ultrathin transnasal esophagogastroduodenoscopy in the same subjects : pilot study", Dig Endosc, 21, pp.24~28 (2009)
  11. Yoshida N, "Risk of lens cloudiness during colorectal endoscopic submucosal dissection and ability of a novel lens cleaner to maintain and restore endoscopic view", Dig Endosc, 27, pp.609~617 (2015)
  12. Yoshida N, "A novel lens cleaner to prevent water drop adhesions during colonoscopy and esophagogastroduodenoscopy", Endosc Int Open, 5, pp.E1235~E1241 (2017)
  13. Song S, "Simultaneous removal of phenanthrene and cadmium from contaminated soils by saponin, a plant-derived biosurfactant", Environ Pollut, 156, pp.1368~1370 (2008)
  14. Tatsumi Y, "Current status and evaluation of transnasal esophagogastroduodenoscopy", Dig Endosc, 21, pp.141~146 (2009)
  15. Saito Y, "A prospective, multicenter study of 1111 colorectal endoscopic submucosal dissections(with video)", Gastrointest Endosc, 72, pp.1217~1225 (2010)

이 간행물의 다른 논문 (24건)