본문 바로가기
KERD
논문KCI 등재

Superior Specimen and Diagnostic Accuracy with Endoscopic Ultrasound-Guided Liver Biopsies Using 19-Gauge versus 22-Gauge Core Needles

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an effective and safe method of procuring liver tissue. The aims of this study were to assess and compare the outcomes and tissue adequacy of a single-pass, single-actuation, wet suctiontechnique between 19 G and 22 G needles in patients undergoing EUS-LB. Methods: We performed a prospective case series study of 20 patients undergoing EUS-LB at a single center between September2017 and April 2020. The primary objective was to evaluate differences in sample adequacy via a single actuation wet suctiontechnique between a 19 G core needle and a 22 G core needle. Adequacy was gauged by cumulative core biopsy length and thenumber of portal tracts visualized. Results: The 19 G needle provided a longer core length (2.5 cm vs. 1.2 cm, p<0.0001), more complete portal tracts (5.8 vs. 1.7,p<0.0001), more total tracts (8.8 vs. 3, p<0.0001), and a longer, intact, fragment length (0.75 cm vs. 0.32 cm, p<0.0006). The 19 Gneedle was superior in providing adequate (60% vs. 5%, p<0.001) and diagnostic pathologic samples (85% vs. 10%, p<0.001). Conclusions: A single-pass, single-actuation, wet suction technique using a 19 G needle is superior to that using a 22 G needle fortissue acquisition and sample adequacy in EUS-LB.

Abstract

Background/Aims: Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an effective and safe method of procuring liver tissue. The aims of this study were to assess and compare the outcomes and tissue adequacy of a single-pass, single-actuation, wet suctiontechnique between 19 G and 22 G needles in patients undergoing EUS-LB. Methods: We performed a prospective case series study of 20 patients undergoing EUS-LB at a single center between September2017 and April 2020. The primary objective was to evaluate differences in sample adequacy via a single actuation wet suctiontechnique between a 19 G core needle and a 22 G core needle. Adequacy was gauged by cumulative core biopsy length and thenumber of portal tracts visualized. Results: The 19 G needle provided a longer core length (2.5 cm vs. 1.2 cm, p<0.0001), more complete portal tracts (5.8 vs. 1.7,p<0.0001), more total tracts (8.8 vs. 3, p<0.0001), and a longer, intact, fragment length (0.75 cm vs. 0.32 cm, p<0.0006). The 19 Gneedle was superior in providing adequate (60% vs. 5%, p<0.001) and diagnostic pathologic samples (85% vs. 10%, p<0.001). Conclusions: A single-pass, single-actuation, wet suction technique using a 19 G needle is superior to that using a 22 G needle fortissue acquisition and sample adequacy in EUS-LB.

참고문헌 (16)

  1. Schulman AR, "Optimizing EUS-guided liver biopsy sampling : comprehensive assessment of needle types and tissue acquisition techniques", Gastrointest Endosc, 85, pp.419~426 (2017)
  2. Pineda JJ, "EUS-guided liver biopsy provides diagnostic samples comparable with those via the percutaneous or transjugular route", Gastrointest Endosc, 83, pp.360~365 (2016)
  3. Diehl DL, "Endoscopic ultrasound-guided liver biopsy : a multicenter experience", Endosc Int Open, 3, pp.E210~E215 (2015)
  4. Parekh PJ, "Endoscopic ultrasound-guided liver biopsy", Endosc Ultrasound, 4, pp.85~91 (2015)
  5. Mohan BP, "Efficacy and safety of EUS-guided liver biopsy : a systematic review and meta-analysis", Gastrointest Endosc, 89, pp.238~246 (2019)
  6. Bazerbachi F, "EUS-guided core liver biopsy sampling using a 22-gauge fork-tip needle : a prospective blinded trial for histologic and lipidomic evaluation in nonalcoholic fatty liver disease", Gastrointest Endosc, 90, pp.926~932 (2019)
  7. Hasan MK, "Endoscopic ultrasound-guided liver biopsy using a 22-G fine-needle biopsy needle : a prospective study", Endoscopy, 51, pp.818~824 (2019)
  8. Ching-Companioni RA, "19 G aspiration needle versus 19 G core biopsy needle for endoscopic ultrasound-guided liver biopsy : a prospective randomized trial", Endoscopy, 51, pp.1059~1065 (2019)
  9. Nieto J, "EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1actuation wet suction technique", Gastrointest Endosc, 87, pp.469~475 (2018)
  10. Rockey DC, "Liver biopsy", Hepatology, 49, pp.1017~1044 (2009)
  11. Caldwell S, "Liver biopsy : the reports of its demise are greatly exaggerated", Clin Transl Gastroenterol, 7, pp.e171~ (2016)
  12. Bravo AA, "Liver biopsy", N Engl J Med, 344, pp.495~500 (2001)
  13. Stavropoulos SN, "High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction", Gastrointest Endosc, 75, pp.310~318 (2012)
  14. Shuja A, "Comparison of EUS-guided versus percutaneous and transjugular approaches for the performance of liver biopsies", Dig Liver Dis, 51, pp.826~830 (2019)
  15. Mok SR, "19 versus 22 gauge fine-needle biopsy for endoscopic ultrasound guided liver biopsy(EUS-LB) : a prospective randomized trial", Gastrointest Endosc, 85(5 Suppl), pp.AB473~AB474 (2017)
  16. Bhat I, "EUS-guided liver biopsy using 22G FNB vs. 19G FNB needles: a prospective comparison of core specimen size and diagnostic adequacy", Gastrointest Endosc, 89(6 Suppl), pp.AB293~ (2019)

관련 논문AI추천

Comparison of Endoscopic Ultrasound Biopsy Needles for Endoscopic Ultrasound-Guided Liver BiopsyArmen Eskandari, Dorina Gui, Heejung Bang, Patrick Koo, Shiro Urayama대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제4호Endoscopic Ultrasound-Guided Liver Biopsy Using a Core Needle for Hepatic Solid Mass김태현, 전형구, 최금하, Hee Chan Yang대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제4호Comparison of the Diagnostic Yield of the Standard 22-Gauge Needle and the New 20-Gauge Forward-Bevel Core Biopsy Needle for Endoscopic Ultrasound-Guided Tissue Acquisition from Pancreatic LesionsHirotoshi Ishiwatari, Hiroyuki Matsubayashi, Hiroyuki Ono, Junya Sato, Keiko Sasaki, Kenichiro Imai, Kinichi Hotta, Kohei Takizawa, Masao Yoshida, Naomi Kakushima, Noboru Kawata, Sayo Ito, Shinya Fujie거트앤리버 소화기연관학회협의회 · Gut and Liver2019 · 제13권 제3호Endoscopic Ultrasound-Guided, Percutaneous, and Transjugular Liver Biopsy: A Comparative Systematic Review and Meta-AnalysisAhmad Najdat Bazarbashi, Basile Njei, Harry R. Aslanian, Marvin Ryou, Thiruvengadam Muniraj, Thomas R. McCarty대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제5호Endoscopic Ultrasound-Guided Fine Needle Aspiration Using a 22-G Needle for Hepatic Lesions: Single-Center ExperienceAli Koç, Deniz Atasoy, Ebru Akay, Engin Altınkaya, Erkan Caglar, Hatice Karaman, Tamer Ertan대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제3호Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using a 20-Gauge Menghini Needle with a Lateral Forward Bevel and a 22-Gauge Franseen Needle: A Single-Center Large Cohort StudyAkiyoshi Kasuga, Masato Matsuyama, Masato Ozaka, Naoki Sasahira, Ryo Kanata, Takaaki Furukawa, Takafumi Mie, Takashi Sasaki, Tsuyoshi Takeda대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제5호

이 간행물의 다른 논문 (25건)