본문 바로가기
KERD
논문KCI 등재

Feasibility of Obtaining Quantitative 3-Dimensional Information Using Conventional Endoscope: A Pilot Study

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods: Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results: The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions: It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object.

Abstract

Background/Aims: Three-dimensional (3D) imaging is gaining popularity and has been partly adopted in laparoscopic surgery or robotic surgery but has not been applied to gastrointestinal endoscopy. As a first step, we conducted an experiment to evaluate whether images obtained by conventional gastrointestinal endoscopy could be used to acquire quantitative 3D information. Methods: Two endoscopes (GIF-H260) were used in a Borrmann type I tumor model made of clay. The endoscopes were calibrated by correcting the barrel distortion and perspective distortion. Obtained images were converted to gray-level image, and the characteristics of the images were obtained by edge detection. Finally, data on 3D parameters were measured by using epipolar geometry, two view geometry, and pinhole camera model. Results: The focal length (f) of endoscope at 30 mm was 258.49 pixels. Two endoscopes were fixed at predetermined distance, 12 mm (d12). After matching and calculating disparity (v2-v1), which was 106 pixels, the calculated length between the camera and object (L) was 29.26 mm. The height of the object projected onto the image (h) was then applied to the pinhole camera model, and the result of H (height and width) was 38.21 mm and 41.72 mm, respectively. Measurements were conducted from 2 different locations. The measurement errors ranged from 2.98% to 7.00% with the current Borrmann type I tumor model. Conclusions: It was feasible to obtain parameters necessary for 3D analysis and to apply the data to epipolar geometry with conventional gastrointestinal endoscope to calculate the size of an object.

참고문헌 (16)

  1. Fox WC, "Intraoperative acquisition of three-dimensional imaging for frameless stereotactic guidance during transsphenoidal pituitary surgery using the Arcadis Orbic System", J Neurosurg, 108, pp.746~750 (2008)
  2. Tan GY, "Technological advances in robotic-assisted laparoscopic surgery", Urol Clin North Am, 36, pp.237~249 (2009)
  3. Taffinder N, "The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons", Surg Endosc, 13, pp.1087~1092 (1999)
  4. Perkins N, "Learning to use minimal access surgical instruments and 2-dimensional remote visual feedback: how difficult is the task for novices?", Adv Health Sci Educ Theory Pract, 7, pp.117~131 (2002)
  5. Hofmeister J, "Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems", Semin Laparosc Surg, 8, pp.12~24 (2001)
  6. Pietrabissa A, "Three-dimensional versus two-dimensional video system for the trained endoscopic surgeon and the beginner", Endosc Surg Allied Technol, 2, pp.315~317 (1994)
  7. Wood BJ, "Virtual endoscopy: a promising new technology", Am Fam Physician, 66, pp.107~112 (2002)
  8. Swaminathan R, "Nonmetric calibration of wide-angle lenses and polycameras", IEEE Trans Pattern Anal Mach Intell, 22, pp.1172~1178 (2000)
  9. Heikkila J, "Geometric camera calibration using circular control points", IEEE Trans Pattern Anal Mach Intell, 22, pp.1066~1077 (2000)
  10. Miyamoto K, "Fish eye lens", J Opt Soc Am, 54, pp.1060~1061 (1964)
  11. Kannala J, "A generic camera model and calibration method for conventional, wide-angle, and fish-eye lenses", IEEE Trans Pattern Anal Mach Intell, 28, pp.1335~1340 (2006)
  12. Stehle T, "Camera calibration for fish-eye lenses in endoscopy with an application to 3D reconstruction. In: Institute of Electrical and Electronics Engineers; IEEE Engineering in Medicine and Biology Society; IEEE Signal Processing Society", 4th IEEE International Symposium on Biomedical Imaging, pp.1176~1179 (2007), IEEE
  13. Kong SH, "Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera.", Surg Endosc, 24, pp.1132~1143 (2010)
  14. Nakatani H, "Three-dimensional measurement endoscope system with virtual rulers", J Biomed Opt, 12, pp.051803~ (2007)
  15. Hasegawa K, "Endoscope system for high-speed 3D measurement", Syst Comput Jpn, 32, pp.30~39 (2001)
  16. Yamaguchi M, "Three-dimensional determination of gastric ulcer size with laser endoscopy", Endoscopy, 20, pp.263~266 (1988)

관련 논문AI추천

Three-Dimensional Flexible Endoscopy Can Facilitate Efficient and Reliable Endoscopic Hand Suturing: An ex-vivo StudyEriko Koizumi, Hiroto Noda, Jun Omori, Katsuhiko Iwakiri, Kazutoshi Higuchi, Kumiko Kirita, Masahiro Suzuki, Mitsuru Kaise, Naohiko Akimoto, Osamu Goto, Takamitsu Umeda, Teppei Akimoto대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제3호Recent Development of Computer Vision Technology to Improve Capsule Endoscopy박준석, Hoon Jai Chun, Ju-Hong Yoon, Jungho Kim, Min-Gyu Park, Youngbae Hwang, Yun Jeong Lim대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제4호Factors influencing endoscopic estimation of colon polyp size in a colon modelJaimy A. Simmering, Koen Robert Beukema, Marjolein Brusse-Keizer, Peter B. Mensink, Rutger Quispel, Sneha John대한소화기내시경학회 · Clinical Endoscopy2022 · 제55권 제4호A Pilot Study of Endoscopic Submucosal Dissection Using an Endoscopic Assistive Robot in a Porcine Stomach Model김병곤, Bora Keum, Daehie Hong, Hoon Jai Chun, Hyuk Soon Choi, Jung Min Lee, Jun Ho Hong, Sei Hoon Park, Seung Han Kim거트앤리버 소화기연관학회협의회 · Gut and Liver2019 · 제13권 제4호Three-dimensional imaging of subepithelial tumors: feasibility and utility in preoperative assessment - a retrospective single-center observational study in JapanEriko Koizumi, Hiroto Noda, Katsuhiko Iwakiri, Kazutoshi Higuchi, Osamu Goto, Shun Nakagome, Tsugumi Habu, Yumiko Ishikawa대한소화기내시경학회 · Clinical Endoscopy2025 · 제58권 제6호Efficacy of a Three-Dimensional-Printed Training Simulator for Endoscopic Biopsy in the Stomach나희경, Do Hoon Kim, Gin Hyug Lee, Ho June Song, Hwoon-Yong Jung, Jeong Hoon Lee, Ji Yong Ahn, Kee Don Choi, Kee Wook Jung, Minkyu Han, Sunpyo Lee거트앤리버 소화기연관학회협의회 · Gut and Liver2018 · 제12권 제2호

이 간행물의 다른 논문 (13건)