본문 바로가기
KERD
논문KCI 등재

Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound–guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52–0.90) and strict criteria (OR, 0.58; 95% CI, 0.46–0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76–1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

Abstract

Background/Aims: This meta-analysis analyzed the effect of an indwelling biliary stent on endoscopic ultrasound (EUS)-guided tissue acquisition from pancreatic lesions. Methods: A literature search was performed to identify studies published between 2000 and July 2022 comparing the diagnostic outcomes of EUS-tissue acquisition (TA) in patients with or without biliary stents. For non-strict criteria, samples reported as malignant or suspicious for malignancy were included, whereas for strict criteria, only samples reported as malignant were included in the analysis. Results: Nine studies were included in this analysis. The odds of an accurate diagnosis were significantly lower in patients with indwelling stents using both non-strict (odds ratio [OR], 0.68; 95% confidence interval [CI], 0.52–0.90) and strict criteria (OR, 0.58; 95% CI, 0.46–0.74). The pooled sensitivity with and without stents were similar (87% vs. 91%) using non-strict criteria. However, patients with stents had a lower pooled sensitivity (79% vs. 88%) when using strict criteria. The sample inadequacy rate was comparable between groups (OR, 1.12; 95% CI, 0.76–1.65). The diagnostic accuracy and sample inadequacy were comparable between plastic and metal biliary stents. Conclusions: The presence of a biliary stent may negatively affect the diagnostic outcome of EUS-TA for pancreatic lesions.

참고문헌 (34)

  1. Guarneri G, "Diagnostic strategy with a solid pancreatic mass", Presse Med, 48(3 Pt 2), pp.e125~ (2019)
  2. Christoph F. Dietrich, "Modern ultrasound imaging of pancreatic tumors", ULTRASONOGRAPHY, 39(2), pp.105~113 (2020), 대한초음파의학회
  3. Dewitt J, "Comparison of endoscopic ultrasound and computed tomography for the preoperative evaluation of pancreatic cancer : a systematic review", Clin Gastroenterol Hepatol, 4, pp.717~725 (2006)
  4. Gomes RM, "Unexpected benign histopathology after pancreatoduodenectomy for presumed malignancy : accepting the inevitable", Langenbecks Arch Surg, 401, pp.169~179 (2016)
  5. Manzia TM, "Benign disease and unexpected histological findings after pancreaticoduodenectomy : the role of endoscopic ultrasound fine needle aspiration", Ann R Coll Surg Engl, 92, pp.295~301 (2010)
  6. Asbun HJ, "When to perform a pancreatoduodenectomy in the absence of positive histology? : a consensus statement by the International Study Group of Pancreatic Surgery", Surgery, 155, pp.887~892 (2014)
  7. Banafea O, "Endoscopic ultrasonography with fine-needle aspiration for histological diagnosis of solid pancreatic masses : a meta-analysis of diagnostic accuracy studies", BMC Gastroenterol, 16, pp.108~ (2016)
  8. Micames C, "Lower frequency of peritoneal carcinomatosis in patients with pancreatic cancer diagnosed by EUS-guided FNA vs. percutaneous FNA", Gastrointest Endosc, 58, pp.690~695 (2003)
  9. Ross WA, "Combined EUS with FNA and ERCP for the evaluation of patients with obstructive jaundice from presumed pancreatic malignancy", Gastrointest Endosc, 68, pp.461~466 (2008)
  10. Gardner TB, "Combined EUS with FNA and ERCP for the evaluation of pancreatic adenocarcinoma in the very elderly", Gastrointest Endosc, 69, pp.AB250~ (2009)
  11. Cannon ME, "EUS compared with CT, magnetic resonance imaging, and angiography and the influence of biliary stenting on staging accuracy of ampullary neoplasms", Gastrointest Endosc, 50, pp.27~33 (1999)
  12. Chen CH, "Preoperative evaluation of periampullary tumors by endoscopic sonography, transabdominal sonography, and computed tomography", J Clin Ultrasound, 29, pp.313~321 (2001)
  13. Fusaroli P, "The influence of endoscopic biliary stents on the accuracy of endoscopic ultrasound for pancreatic head cancer staging", Endoscopy, 39, pp.813~817 (2007)
  14. Page MJ, "The PRISMA 2020 statement : an updated guideline for reporting systematic reviews", BMJ, 372, pp.n71~ (2021)
  15. Higgins JP, "The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials", BMJ, 343, pp.d5928~ (2011)
  16. Sterne JA, "ROBINS-I : a tool for assessing risk of bias in non-randomised studies of interventions", BMJ, 355, pp.i4919~ (2016)
  17. Fisher JM, "The impact of prior biliary stenting on the accuracy and complication rate of endoscopic ultrasound fine-needle aspiration for diagnosing pancreatic adenocarcinoma", Pancreas, 40, pp.21~24 (2011)
  18. Ranney N, "Impact of biliary stents on EUS-guided FNA of pancreatic mass lesions", Gastrointest Endosc, 76, pp.76~83 (2012)
  19. Siddiqui AA, "Comparison of the influence of plastic and fully covered metal biliary stents on the accuracy of EUS-FNA for the diagnosis of pancreatic cancer", Dig Dis Sci, 57, pp.2438~2445 (2012)
  20. Kim JJ, "Lower yield of endoscopic ultrasound-guided fine-needle aspiration in patients with pancreatic head mass with a biliary stent", Dig Dis Sci, 60, pp.543~549 (2015)
  21. Antonini F, "Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles", Dig Liver Dis, 49, pp.898~902 (2017)
  22. Kulkarni AA, "Presence of an indwelling biliary stent in patients with pancreatic head masses: does it impact endoscopic ultrasound evaluation?", Gastrointest Endosc, 85, pp.AB439~ (2017)
  23. Bekkali NL, "Impact of metal and plastic stents on endoscopic ultrasound-guided aspiration cytology and core histology of head of pancreas masses", Endoscopy, 51, pp.1044~1050 (2019)
  24. Crinò SF, "Impact of biliary stents on the diagnostic accuracy of EUS-guided fine-needle biopsy of solid pancreatic head lesions : a multicenter study", Endosc Ultrasound, 10, pp.440~447 (2021)
  25. Constantinescu A, "Impact of biliary stenting in endoscopic ultrasound-guided tissue acquisition among patients with pancreatic cancer", J Clin Ultrasound, 50, pp.844~849 (2022)
  26. Bao PQ, "Endoscopic ultrasound and computed tomography predictors of pancreatic cancer resectability", J Gastrointest Surg, 12, pp.10~16 (2008)
  27. Nakai Y, "International consensus statements for endoscopic management of distal biliary stricture", J Gastroenterol Hepatol, 35, pp.967~979 (2020)
  28. Arya N, "A proposal for the ideal algorithm for the diagnosis, staging, and treatment of pancreas masses suspicious for pancreatic adenocarcinoma : results of a working group of the Canadian Society for Endoscopic Ultrasound", Endosc Ultrasound, 9, pp.154~161 (2020)
  29. Polkowski M, "Technical aspects of endoscopic ultrasound(EUS)-guided sampling in gastroenterology : European Society of Gastrointestinal Endoscopy(ESGE)Technical Guideline : March 2017", Endoscopy, 49, pp.989~1006 (2017)
  30. Kamata K, "Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap : a multicenter randomized trial", Endoscopy, 48, pp.632~638 (2016)
  31. Gimeno-García AZ, "Randomized controlled trial comparing stylet-free endoscopic ultrasound-guided fine-needle aspiration with 22-G and 25-G needles", Dig Endosc, 26, pp.467~473 (2014)
  32. Fabbri C, "Endoscopic ultrasound-guided fine needle aspiration with 22-and 25-gauge needles in solid pancreatic masses : a prospective comparative study with randomisation of needle sequence", Dig Liver Dis, 43, pp.647~652 (2011)
  33. Oppong KW, "Impact of prior biliary stenting on diagnostic performance of endoscopic ultrasound for mesenteric vascular staging in patients with head of pancreas and periampullary malignancy", BMJ Open Gastroenterol, 9, pp.e000864~ (2022)
  34. Ignee A, "Endoscopic ultrasound elastography of small solid pancreatic lesions : a multicenter study", Endoscopy, 50, pp.1071~1079 (2018)

관련 논문AI추천

Endoscopic Ultrasound-Guided Fine Needle Aspiration and Endoscopic Retrograde Cholangiopancreatography-Based Tissue Sampling in Suspected Malignant Biliary Strictures: A Meta-Analysis of Same-Session ProceduresChristopher C. Thompson, Diogo Turiani Hourneax de Moura, Eduardo Guimarães Hourneaux De Moura, Igor Braga Ribeiro, Marvin Ryou, Wanderlei Marques Bernardo대한소화기내시경학회 · Clinical Endoscopy2020 · 제53권 제4호Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-AnalysisBenjamin D. Renelus, Daniel S. Jamorabo, Iman Boston, John M. Poneros, William M. Briggs대한소화기내시경학회 · Clinical Endoscopy2021 · 제54권 제2호How to optimize the diagnostic yield of endoscopic ultrasound-guided fine-needle sampling in solid pancreatic lesions from a technical perspective김홍주, Kim Nam Hee소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2023 · 제12권 제2호Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysisGeun Joo Choi, Hyoung-Chul Oh, Hyun Kang, Jae Young Lee, Jung Sik Choi대한내과학회 · The Korean Journal of Internal Medicine2016 · 제31권 제6호22-gauge Co-Cr versus stainless-steel Franseen needles for endoscopic ultrasound-guided tissue acquisition in patients with solid pancreatic lesionsAkashi Fujita, Kei Sugimoto, Masafumi Mizuide, Rie Shiomi, Ryuhei Jinushi, Shomei Ryozawa, Takahiro Shin, Tomoaki Tashima, Yuki Tanisaka, Yumi Mashimo대한소화기내시경학회 · Clinical Endoscopy2024 · 제57권 제2호Efficacy of endoscopic ultrasound-guided biliary drainage of malignant biliary obstruction: a systematic review and meta-analysis of randomized controlled trialsFabeeha Shaheen, Hafsa Azam, Laila Manzoor, Muaaz Masood, Muhammad Abdullah Bin Azhar, Rajesh Krishnamoorthi, Syed Sarmad Javaid, Yousaf Zafar대한소화기내시경학회 · Clinical Endoscopy2025 · 제58권 제4호

이 간행물의 다른 논문 (18건)