Efficacy of an assistive guide tube for improved endoscopic access to gastrointestinal lesions: an in vivo study in a porcine model
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background/Aims: Guide tube-assisted endoscopy for procedures that require repeated endoscopic access is safer and more effective than conventional endoscopy. However, its effectiveness has not been confirmed in animal studies. We assessed the usefulness of guide tube-assisted endoscopic procedures in an in vivo porcine model. Methods: Five different guide tube-assisted endoscopic procedures were performed by experienced endoscopists on a pig weighing 32 kg. To evaluate the efficacy of these procedures, we compared the endoscopic approach time when a guide tube was used to that when it was not. Additional endoscopic procedures using a guide tube were performed, including multiple foreign body extractions, multiple polypectomies, and multiple submucosal dissections. To evaluate safety, we compared the insertion force into the proximal esophagus between the guide tube and conventional overtube methods. Results: Using the endoscopic approach with a guide tube required a shorter average approach time to reach the three target lesions than when using the endoscopic approach without a guide tube (p<0.001). Compared to the conventional overtube method, the guide tube method produced a lower average resistance during insertion into the upper esophagus (p<0.001). Conclusions: Guide tube-assisted endoscopic procedures are effective and safe for repeated endoscopic access in an in vivo porcine model.
Abstract
Background/Aims: Guide tube-assisted endoscopy for procedures that require repeated endoscopic access is safer and more effective than conventional endoscopy. However, its effectiveness has not been confirmed in animal studies. We assessed the usefulness of guide tube-assisted endoscopic procedures in an in vivo porcine model. Methods: Five different guide tube-assisted endoscopic procedures were performed by experienced endoscopists on a pig weighing 32 kg. To evaluate the efficacy of these procedures, we compared the endoscopic approach time when a guide tube was used to that when it was not. Additional endoscopic procedures using a guide tube were performed, including multiple foreign body extractions, multiple polypectomies, and multiple submucosal dissections. To evaluate safety, we compared the insertion force into the proximal esophagus between the guide tube and conventional overtube methods. Results: Using the endoscopic approach with a guide tube required a shorter average approach time to reach the three target lesions than when using the endoscopic approach without a guide tube (p<0.001). Compared to the conventional overtube method, the guide tube method produced a lower average resistance during insertion into the upper esophagus (p<0.001). Conclusions: Guide tube-assisted endoscopic procedures are effective and safe for repeated endoscopic access in an in vivo porcine model.
참고문헌 (12)
- Lee DS, "Technical feasibility of a guidetube for various endoscopic procedures in human gastrointestinal simulators", Clin Endosc, 52, pp.247~251 (2019)
- Holderman WH, "Endoscopic findings and overtube-related complications associated with esophageal variceal ligation", J Clin Gastroenterol, 21, pp.91~94 (1995)
- Dinning JP, "Delayed presentation of esophageal perforation as a result of overtube placement", J Clin Gastroenterol, 24, pp.250~252 (1997)
- Levy R, "Separation of an overtube from the bite block during band ligation of esophageal varices", Gastrointest Endosc, 46, pp.66~68 (1997)
- Jeffries MA, "Overtube separation", Gastrointest Endosc, 47, pp.435~436 (1998)
- ASGE Technology Committee, "Overtube use in gastrointestinal endoscopy", Gastrointest Endosc, 70, pp.828~834 (2009)
- Perencevich M, "A multidisciplinary approach to the diagnosis and management of multiple colorectal polyps", Gastroenterol Hepatol(N Y), 7, pp.420~423 (2011)
- Wang X, "The removal of foreign body ingestion in the upper gastrointestinal tract : a retrospective study of 1, 182 adult cases", Ann Transl Med, 9, pp.502~ (2021)
- Goldschmiedt M, "A safety maneuver for placing overtubes during endoscopic variceal ligation", Gastrointest Endosc, 38, pp.399~400 (1992)
- Chen CY, "A simple maneuver for placing an overtube during endoscopic variceal ligation", Gastrointest Endosc, 41, pp.83~84 (1995)
- Pai RD, "Endoscopic evaluation of the defunctionalized stomach by using ShapeLock technology(with video)", Gastrointest Endosc, 66, pp.578~581 (2007)
- Raju GS, "ShapeLock : a rapid access port for redeployment of a colonoscope into the proximal colon to facilitate multiple polypectomies in a single session", Gastrointest Endosc, 61, pp.768~770 (2005)
