Thoracic Endovascular Aortic Repair with the Chimney Technique for Blunt Traumatic Pseudoaneurysm of the Aortic Arch in a No-Option Patient
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A 42-year-old man was involved in a motor vehicle collision. Imaging studies revealed the presence of a post-traumatic aortic pseudo-aneurysm (about 34×26 cm) arising from the descending thoracic aorta at the level of the left subclavian artery (LSA), prone to rupture. Thoracic endovascular aneurysm repair (TEVAR) was the only feasible option due to his poor overall medical status. In this case, LSA needed to be covered in order to extend the proximal landing zone. Eventually, modified TEVAR was successfully performed by means of the chimney technique to preserve flow to the LSA and to prevent flow into the pseudoaneurysmal sac.
Abstract
A 42-year-old man was involved in a motor vehicle collision. Imaging studies revealed the presence of a post-traumatic aortic pseudo-aneurysm (about 34×26 cm) arising from the descending thoracic aorta at the level of the left subclavian artery (LSA), prone to rupture. Thoracic endovascular aneurysm repair (TEVAR) was the only feasible option due to his poor overall medical status. In this case, LSA needed to be covered in order to extend the proximal landing zone. Eventually, modified TEVAR was successfully performed by means of the chimney technique to preserve flow to the LSA and to prevent flow into the pseudoaneurysmal sac.
참고문헌 (16)
- Alla VM, "Thoracic aortic pseudoaneurysm following noncardiovascular surgery: a rare complication that can mimic common chest emergencies", South Med J, 103, pp.1186~1188 (2010)
- Chaikof EL, "Endovascular repair for diverse pathologies of the thoracic aorta: an initial decade of experience", J Am Coll Surg, 208, pp.802~816 (2009)
- Kpodonu J, "Endovascular repair of an ascending aortic pseudoaneurysm with a septal occluder device: mid-term follow-up", Ann Thorac Surg, 85, pp.349~351 (2008)
- 심원흠, "Hybrid Approach for Complex Thoracic Aortic Pathology", Korean Circulation Journal, 40(8), pp.368~369 (2010), 대한심장학회
- 강웅철, "Combined Open and Endovascular Repair for Aortic Arch Pathology", Korean Circulation Journal, 40(8), pp.399~404 (2010), 대한심장학회
- Razzouk A, "Pseudoaneurysms of the aorta after cardiac surgery or chest trauma", Am Surg, 59, pp.818~823 (1993)
- Bizzarri F, "Traumatic aortic arch false aneurysm after blunt chest trauma in a motocross rider", J Cardiothorac Surg, 3, pp.23~ (2008)
- Woo EY, "Left subclavian artery coverage during thoracic endovascular aortic repair: a single-center experience", J Vasc Surg, 48, pp.555~560 (2008)
- Peterson BG, "Utility of left subclavian artery revascularization in association with endoluminal repair of acute and chronic thoracic aortic pathology", J Vasc Surg, 43, pp.433~439 (2006)
- Reece TB, "Reevaluating the need for left subclavian artery revascularization with thoracic endovascular aortic repair", Ann Thorac Surg, 84, pp.1201~1205 (2007)
- Sugiura K, "The applicability of chimney grafts in the aortic arch", J Cardiovasc Surg, 50, pp.475~481 (2009)
- Ohrlander T, "The chimney graft: a technique for preserving or rescuing aortic branch vessels in stent-graft sealing zones", J Endovasc Ther, 15, pp.427~432 (2008)
- Greenberg RK, "Should patients with challenging anatomy be offered endovascular aneurysm repair?", J Vasc Surg, 38, pp.990~996 (2003)
- Criado FJ, "A percutaneous technique for preservation of arch branch patency during thoracic endovascular aortic repair (TEVAR): retrograde catheterization and stenting", J Endovasc Ther, 14, pp.54~58 (2007)
- Hiramoto JS, "A double-barrel stent-graft for endovascular repair of the aortic arch", J Endovasc Ther, 13, pp.72~76 (2006)
- Feng R, "Double-chimney technology for treating secondary type I endoleak after endovascular repair for complicated thoracic aortic dissection", J Vasc Surg, 54, pp.212~215 (2011)