Simultaneous determination of ampicillin sodium and sulbactam sodium in powder for injection by HPLC
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Ampicillin and Sulbactam (2:1, w/w) are combined in formulation to provide broader antibacterial action in treatment of many infections. The development of analytical method for simultaneouly determine these two compounds was difficult because of the differences in their chemical structures and ratio in the formulation. Current published methods still have some limitations. In this study, we developed an alternative highperformance liquid chromatography (HPLC) assay method for simultaneously determination of ampicillin sodium and sulbactam sodium in powder for injection. Method validation of HPLC method was conducted to determine linearity, precision, accuracy, system suitability, robustness. The linearity of the calibration curves in the desired concentration range was good (r2 > 0.9994). RSDs of intra-day and inter-day precision obtained were less than 2.00 %. Accuracy was obtained with the recoveries in range of 98.42 % and 101.36 %. As a result of system suitability, RSD of both retention time and the peak area obtained were not more than 1.0 %. The values of plate number were more than 7000 and symmetric factors obtained were 0.8. As intermediate-precision and robustness of the developed assay, it could be expected to become valuable tools for revising the Korean Pharmacopoeia (KP XI).
Abstract
Ampicillin and Sulbactam (2:1, w/w) are combined in formulation to provide broader antibacterial action in treatment of many infections. The development of analytical method for simultaneouly determine these two compounds was difficult because of the differences in their chemical structures and ratio in the formulation. Current published methods still have some limitations. In this study, we developed an alternative highperformance liquid chromatography (HPLC) assay method for simultaneously determination of ampicillin sodium and sulbactam sodium in powder for injection. Method validation of HPLC method was conducted to determine linearity, precision, accuracy, system suitability, robustness. The linearity of the calibration curves in the desired concentration range was good (r2 > 0.9994). RSDs of intra-day and inter-day precision obtained were less than 2.00 %. Accuracy was obtained with the recoveries in range of 98.42 % and 101.36 %. As a result of system suitability, RSD of both retention time and the peak area obtained were not more than 1.0 %. The values of plate number were more than 7000 and symmetric factors obtained were 0.8. As intermediate-precision and robustness of the developed assay, it could be expected to become valuable tools for revising the Korean Pharmacopoeia (KP XI).
참고문헌 (16)
- "Record Name: Ampicillin Sodium"[URL]
- C. González, , Rev. Med. Chil, 118(5), pp.548~554 (1990)
- "Record Name: Sulbactam Sodium"[URL]
- M. Akova, , Clin. Microbiol. Infect, 14(Suppl 1), pp.185~188 (2008)
- P. I. Rafailidis, , Drugs, 67(13), pp.1829~1849 (2007)
- K. Tsuji, , J. Pharm. Sci, 64(9), pp.1542~1545 (1975)
- R. G. Lauback, , J. Liq. Chromatogr. Relat. Technol, 7(6), pp.1243~1265 (1984)
- S. S. Zarapkar, , Indian Drugs, 37(4), pp.200~203 (2000)
- C. M. Carceles, , Res. Vet. Sci, 61, pp.143~146 (1996)
- J. Haginaka, , J. Chromatogr, 532(1), pp.87~94 (1990)
- Ministry of Food and Drug Safety, "The Korean Pharmacopoeia" (2014)
- The United States Pharmacopeia Convention, "The United States Pharmacopeia, USP 41 NF 36", ~ (2017)
- The Ministry of Health, Labour and Welfare, "The Japanese Pharmacopoeia" (2016)
- ICH Guideline, "Q2(R1): validation of Analytical Procedures: Text and Methodology Q2(R1) in ICH Harmonised Tripartite Guideline", ~ (2005)
- "Ministry of Food and Drug Safety No. 2009-173", ~ (2009)
- "Ministry of Food and Drug Safety, No. C0-2012-2-005", ~ (2012)