초록

Purpose: To evaluate the long-term maintenance rate and associated factors of silicone punctal plugs in patients with Sjögren’s syndrome (SS). Materials and Methods: We retrospectively reviewed the medical records of 163 patients with SS who underwent silicone punctal plug insertion between December 2013 and July 2021 at Severance Hospital. The status of punctal plug insertions was classified into the following three categories by the clinician: maintenance, spontaneous loss, and intended removal. Cox proportional haz ards model was used to evaluate the risk factors for spontaneous loss. Results: The mean maintenance period was 12.8±15.3 (median 7.07) months. The rate of spontaneous loss was 58%, and the rate of punctal plug removal by the clinician was 14%. The number of prior plug insertions was a risk factor for spontaneous loss [hazard ratio (HR) 1.055, p=0.035]. The upper eyelid punctum was at a higher risk than the lower one (p=0.042). Small-sized plugs showed a significantly higher risk for spontaneous loss than large-sized ones (HR 1.287, p=0.035). Flow-controller type plugs were more vul nerable to spontaneous loss than complete occluders [Micro FlowTM vs. EagleFlex® (HR 2.707, p=0.008) and Micro FlowTM vs. Ul traplugTM (HR 3.402, p=0.005)]. The most common reason for removal was tear overflow (5.6%). Conclusion: In repeated insertion, characteristics of the punctal plug, including the type and size, and location of plug insertion, influenced the spontaneous loss of plugs. The management of punctal plugs, including insertion, maintenance, and removal, re quires personalized strategies for versatile situations.

Abstract

Purpose: To evaluate the long-term maintenance rate and associated factors of silicone punctal plugs in patients with Sjögren’s syndrome (SS). Materials and Methods: We retrospectively reviewed the medical records of 163 patients with SS who underwent silicone punctal plug insertion between December 2013 and July 2021 at Severance Hospital. The status of punctal plug insertions was classified into the following three categories by the clinician: maintenance, spontaneous loss, and intended removal. Cox proportional haz ards model was used to evaluate the risk factors for spontaneous loss. Results: The mean maintenance period was 12.8±15.3 (median 7.07) months. The rate of spontaneous loss was 58%, and the rate of punctal plug removal by the clinician was 14%. The number of prior plug insertions was a risk factor for spontaneous loss [hazard ratio (HR) 1.055, p=0.035]. The upper eyelid punctum was at a higher risk than the lower one (p=0.042). Small-sized plugs showed a significantly higher risk for spontaneous loss than large-sized ones (HR 1.287, p=0.035). Flow-controller type plugs were more vul nerable to spontaneous loss than complete occluders [Micro FlowTM vs. EagleFlex® (HR 2.707, p=0.008) and Micro FlowTM vs. Ul traplugTM (HR 3.402, p=0.005)]. The most common reason for removal was tear overflow (5.6%). Conclusion: In repeated insertion, characteristics of the punctal plug, including the type and size, and location of plug insertion, influenced the spontaneous loss of plugs. The management of punctal plugs, including insertion, maintenance, and removal, re quires personalized strategies for versatile situations.

참고문헌 (19)

  1. Bjordal O, "Primary Sjögren’s syndrome and the eye", Surv Ophthalmol, 65, pp.119~132 (2020)
  2. Jehangir N, "Comprehensive review of the literature on existing punctal plugs for the management of dry eye disease", J Ophthalmol, 2016, pp.9312340~ (2016)
  3. Dursun D, "Ocular surface changes in keratoconjunctivitis sicca with silicone punctum plug occlusion", Curr Eye Res, 26, pp.263~269 (2003)
  4. Marcet MM, "Safety and efficacy of lacrimal drainage system plugs for dry eye syndrome : a report by the American Academy of Ophthalmology", Ophthalmology, 122, pp.1681~1687 (2015)
  5. Balaram M, "Efficacy and tolerability outcomes after punctal occlusion with silicone plugs in dry eye syndrome", Am J Ophthalmol, 131, pp.30~36 (2001)
  6. Kaido M, "Comparison of retention rates and complications of 2 different types of silicon lacrimal punctal plugs in the treatment of dry eye disease", Am J Ophthalmol, 155, pp.648~653 (2013)
  7. Sakamoto A, "Efficacy and retention rate of two types of silicone punctal plugs in patients with and without Sjögren syndrome", Cornea, 23, pp.249~254 (2004)
  8. Boldin I, "Longterm follow-up of punctal and proximal canalicular stenoses after silicone punctal plug treatment in dry eye patients", Am J Ophthalmol, 146, pp.968~972 (2008)
  9. Brissette AR, "Punctal plug retention rates for the treatment of moderate to severe dry eye : a randomized, double-masked, controlled clinical trial", Am J Ophthalmol, 160, pp.238~242 (2015)
  10. Javate RM, "Retention rates and benefits of painless punctal plug FTM in dry eye patients", Orbit, 35, pp.126~131 (2016)
  11. Horwath-Winter J, "Long-term retention rates and complications of silicone punctal plugs in dry eye", Am J Ophthalmol, 144, pp.441~444 (2007)
  12. Parikh NB, "Retention rate of silicone punctal plugs placed by residents in a general clinic setting", Ophthalmic Plast Reconstr Surg, 26, pp.400~402 (2010)
  13. Singh RB, "Efficacy and retention of silicone punctal plugs for treatment of dry eye in patients with and without ocular graft-versus-host-disease", Ocul Surf, 18, pp.731~735 (2020)
  14. Vitali C, "Classification criteria for Sjögren’s syndrome", Ann Rheum Dis, 62, pp.94~95 (2003)
  15. Vitali C, "Classification and diagnostic criteria in Sjögren’s syndrome : a long-standing and still open controversy", Ann Rheum Dis, 76, pp.1953~1954 (2017)
  16. Kim J, "Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes", Acta Ophthalmol, 97, pp.e1089~e1097 (2019)
  17. Tai MC, "The clinical efficacy of silicone punctal plug therapy", Cornea, 21, pp.135~139 (2002)
  18. Kim BM, "Pyogenic granulomas after silicone punctal plugs : a clinical and histopathologic study", Am J Ophthalmol, 139, pp.678~684 (2005)
  19. Fayet B, "Silicone punctal plug extrusion resulting from spontaneous dissection of canalicular mucosa : a clinical and histopathologic report", Ophthalmology, 108, pp.405~409 (2001)