본문 바로가기
KERD
논문KCI 등재

Effectiveness of interference filter for photoluminescence observations: comparison with absorption filters

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류화학

초록

Currently, most photoluminescence reagents used in forensic science have short stokes shift, making it difficult to observe strong photoluminescence due to scattering light from forensic light sources when using filters that are not shieldable. However interference filters can be observed near monochromatic light, making them a better alternative to absorption filters. To verify practical applicability of interference filters, interference filters and three other types of previously frequently used absorption filters were observed using a variety of light source products, and transmission light was cross-compared. Interference filters have a lower slope value than absorption filters, and selectively show only the photoluminescence of reagents, regardless of the type of product from the forensic light source. In addition, tilting the angle of the filter surface for observation lowered the λcut-on, which could replace various types of absorption filters with a single interference filter.

Abstract

Currently, most photoluminescence reagents used in forensic science have short stokes shift, making it difficult to observe strong photoluminescence due to scattering light from forensic light sources when using filters that are not shieldable. However interference filters can be observed near monochromatic light, making them a better alternative to absorption filters. To verify practical applicability of interference filters, interference filters and three other types of previously frequently used absorption filters were observed using a variety of light source products, and transmission light was cross-compared. Interference filters have a lower slope value than absorption filters, and selectively show only the photoluminescence of reagents, regardless of the type of product from the forensic light source. In addition, tilting the angle of the filter surface for observation lowered the λcut-on, which could replace various types of absorption filters with a single interference filter.

참고문헌 (12)

  1. W. C. Lee, , Malaysian J. Forensic Sci, 1(1), pp.17~28 (2010)
  2. E. M. Robinson, "Crime Scene Photography" (2009), Academic Press
  3. S. Bleay, "Fingerprint Development Techniques - Theory and Application" (2018), Wiley & Sons Ltd
  4. M. Takatsu, , J. Forensic Sci, 53(4), pp.823~827 (2008)
  5. S. Bleay, "Fingerprint Source Book v2.0", Home Office Centre for Applied Science and Technology, ~ (2017)
  6. R. Scholte, , Acta Acust. United Acust, 94(3), pp.339~348 (2008)
  7. R. S. Ramotowski, "and Gaensslen’s advances in fingerprint technology" (2012), CRC Press
  8. C. Wallace-Kunkel, , Forensic Sci. Int, 168(1), pp.14~26 (2007)
  9. M. Stoilovic, , J. Forensic Identif, 57(1), pp.4~18 (2007)
  10. H. Bandey, "Fingermark Visualisation Manual", Home Office Police Scientific Development Branch, ~ (2014)
  11. V. G. Sears, , J. Forensic Identif, 50(5), pp.470~480 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (4건)