Abstract
detection of hydrogen peroxide and its electrochemical properties are described. Especially the amperometricsignal was very stable and bigger than any other enzyme electrode studied in this lab. The effect of tissuecomposition on the response was linear within the wide range of experiment and the linearity of Lineweaver-Burk plot showed that the sensing process of the biosensor is by enzymatic catalysis. And pH dependent currentprofile connoted that two isozymes are active in this system.
참고문헌 (50)
- Clark, Jr, L. C, "Ann. N. Y. Acad. Sci.", 102, pp.29~ (1962)
- Updike, S. J, "Nature", 214, pp.986~ (1967)
- Ruiz, B. L, "Anal. Chim. Acta.", 273, pp.425~430 (1993)
- Kano, H, "Anal. Chim. Acta.", 299, pp.69~74 (1994)
- Rosa, C. L, "Anal. Chim. Acta.", 266, pp.129~136 (1955)
- Bonakdar, M, "J. Electroanal. Chem.", 266, pp.47~55 (1989)
- Wang, J, "Anal. Chim. Acta.", 264, pp.7~12 (1992)
- Wang, J, "Anal. Chem.", 60, pp.1545~1548 (1988)
- Messia, M. C, "Anal. Chem.", 68, pp.360~365 (1996)
- Conrath, N, "Anal. Chim. Acta.", 309, pp.47~52 (1995)
- Luque de Castro, M. D, "Anal. Chim. Acta.", 311, pp.281~287 (1995)
- Lee, J. I, "Anal. Chim. Acta.", 313, pp.69~74 (1995)
- Wang, J, "J. Am. Chem. Soc.", 120, pp.1048~1050 (1998)
- Kirchner, J. R, "Encyclopedia of Chemical Technology Vol. 13, 12" (1981), Wiley-Interscience, New York, U. S. A.
- Sax, N. Irving, "Hawley's Condensed Chemical Dictionary" (1987), Van Nostrand Reinhold, New York
- Huckaba, C. E, "J. Am. Chem. Soc.", 70, pp.1640~1644 (1948)
- Hudris, E. C, "Anal. Chem.", 26, pp.320~325 (1954)
- Clapp, P. A, "Anal. Chim. Acta.", 218, pp.331~334 (1989)
- Nakano, T, "Anal. Sci.", 6, pp.823~826 (1990)
- Fang, Y, "Electroanalysis", 4, pp.819~822 (1992)
- Kwon, H. S, "J. Kor. Chem. Soc.", 40(4), pp.278~282 (1996)
- Mansouri, A, "J. Pharm. Biomed. Anal.", 39, pp.22~26 (2005)
- Rocha, F. R. P, "Talanta", 67, pp.673~677 (2005)
- Fernandes, K. F, "Process Biochem.", 40, pp.3441~3445 (2005)
- Wang, J, "Anal. Chim. Acta.", 508, pp.171~176 (2004)
- Economou, A, "Anal. Chim. Acta.", 505, pp.129~133 (2004)
- Lau, C, "Anal. Chim. Acta", 503, pp.235~239 (2004)
- Tang, B, "Spectrochim. Acta, Part A", 59, pp.2867~2874 (2003)
- Zhu, C. Q, "Anal. Chim. Acta.", 514, pp.247~252 (2004)
- Wu, M, "Anal. Biochem.", 340, pp.66~73 (2005)
- Svensson, S, "J. Chromatogr. B", 809, pp.199~203 (2004)
- Beurden, W. J, "Clin. Lab.", 49, pp.637~ (2003)
- Wang, X, "Mater. Lett.", 58, pp.1661~1664 (2004)
- Li, Y, "Sens. Actuators B.", 107, pp.921~928 (2005)
- Yang, Y, "Biosensors and Bioelectronics", 21, pp.74~78 (2005)
- Ozoemena, K. I, "Electrochem. Comm.", 7, pp.679~684 (2005)
- Yoon, K. J, "J. Kor. Chem. Soc.", 41(7), pp.343~356 (1997)
- Yoon, K. J, "J. Kor. Chem. Soc.", 43(3), pp.271~279 (1999)
- Yoon, K. J, "Anal. Sci. Tech.", 13(1), pp.41~48 (2000)
- Lee, B. G, "Anal. Sci. Tech.", 13(3), pp.315~322 (2000)
- Yoon, K. J, "Anal. Sci. Tech", 16(6), pp.504~508 (2003)
- Yoon, K. J, "J. Kor. Chem. Soc.", 48(6), pp.654~658 (2004)
- "Bull. Korean Chem. Soc.", 25(7), pp.997~1002 (2004)
- Yoon, K. J, "J. Kor. Chem. Soc.", 49(3), pp.325~328 (2005)
- Coche-Guerente, L, "Anal. Chim. Acta.", 311, pp.23~30 (1995)
- Wang, J, "Anal. Chim. Acta.", 395, pp.11~16 (1999)
- Wang, J, "Anal. Chim. Acta.", 411, pp.183~189 (2001)
- Wang, J, "Biosensors & Bioelectronics", 17, pp.999~1003 (2002)
- Dixon, M, "Enzymes", pp.633~ (1979), Academic Press Inc., New york, U. S. A.
- Mascini, M, "Anal. Chim. Acta.", 138, pp.65~69 (1982)
관련 논문AI추천
진달래 과산화효소 고정 효소전극을 이용한 과산화수소의 전류법적 검출윤길중한국분석과학회 · 분석과학2014 · 제27권 제4호체리 과산화효소 고정 과산화수소 정량 효소전극의 전기화학적 고찰윤길중, 이범규대한화학회 · 대한화학회지2015 · 제59권 제6호담배조직을 이용한 바이오센서의 과산화수소 환원 최적 산도윤길중대한화학회 · 대한화학회지2004 · 제48권 제6호흑염소 간-조직과 Ferrocene 매개체를 사용한 과산화수소정량 전류법 바이오센서권효식, 김양숙, 박인근대한화학회 · 대한화학회지2004 · 제48권 제5호Electrochemical Studies on the Voltammetric Characteristics of Hydrogen Peroxide Biosensor Immobilized by Natural Rubber윤길중대한화학회 · 대한화학회지2008 · 제52권 제2호전기화학적 방법에 의한 HRP의 최적 pH도출윤길중한국분석과학회 · 분석과학2003 · 제16권 제6호
이 간행물의 다른 논문 (13건)
동위원소희석 질량분석법에 의한 1000ug/g염소 표준용액 중 브롬 불순물 분석송현주, 이동수, 서정기, 박창준pp. 1-8표면 플라스몬 공명 센서의 제작이영훈, 홍태기, 홍석영, 한원식, 정규진, 이상원pp. 9-17A study of characteristics of cumulative deposition of fallout Pu in environmental samples김원용, 송병철, 지광용, 이명호, 박영재pp. 18-30MECC법과 lon-Pairing므로마토그래피법을 이용한 염료성분의 분석정혁pp. 31-38보이차(Pu-erh tea)의 항산화 효과김영만, 김일광, 백순옥, 정은주, 신장철, 김성현, 소은미pp. 39-44