디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가
Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five discshaped specimens (5 mm × 1 mm) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink,Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.
Abstract
This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five discshaped specimens (5 mm × 1 mm) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink,Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.
참고문헌 (29)
- Tsuge T, "Radiopacity of conventional, resinmodified glass ionomer, and resin-based luting materials", J Oral Sci, 51, pp.223~230 (2009)
- ANSI, "ADA", ANSI, ANSI, pp.ADA, 2000[DOI]
- Fraga RC, "Pimenta LA: Physical properties of resinous cements: an in vitro study", J Oral Rehabil, 27, pp.1064~1067 (2000)
- International Standard Organization, "ISO 4049 Dentistry-Polymer-based filling ralm", 1~28 (2009)
- Attar N, "Mechanical and physical properties of contemporary dental luting agents", J Prosthet Dent, 89, pp.127~134 (2003)
- Soares CJ, "In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs", Clin Oral Investig, 11, pp.331~336 (2007)
- Wilson TG, Jr, "The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study", J Periodontol, 80, pp.1388~1392 (2009)
- Dukic W, "Radiopacity of composite dental materials using a digital X-ray system", Dent Mater J, 31, pp.47~53 (2012)
- Pitt Ford TR, "Effect of super-EBA as a root end filling on healing after replantation", J Endod, 21, pp.13~15 (1995)
- Torabinejad M, "Root end filling materials: a review", Endod Dent Traumatol, 12, pp.161~178 (1996)
- Tanomaru-Filho M, "Radiopacity evaluation of root-end filling materials by digitization of images", J Appl Oral Sci, 16, pp.376~379 (2008)
- Baksi BG, "Differences in aluminum equivalent values of endodontic sealers: conventional versus digital radiography", J Endod, 34, pp.1101~1104 (2008)
- Tasdemir T, "Evaluation of the radiopacity of new root canal paste", sealers by digital radiography, 2008, pp.34, 1388~1390
- Gu S, "Radiopacity of dental materials using a digital X-ray system", Dent Mater, 22, pp.765~770 (2006)
- Carvalho-Junior JR, "Radiopacity of root filling materials using digital radiography", Int Endod J, 40, pp.514~520 (2007)
- Wadhwani C, "A descriptive study of the radiographic density of implant restorative cements", J Prosthet Dent, 103, pp.295~302 (2010)
- Altintas SH, "Evaluation of the Radiopacity of Luting Cements by Digital Radiography", J Prosthodont (2012)
- Arash Poorsattar Bejeh Mir, "Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge", Imaging Science in Dentistry, 42(3), pp.163~167 (2012), 대한구강악안면방사선학회
- Amirouche-Korichi A, "Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites", Dent Mater, 25, pp.1411~1418 (2009)
- Watts DC, "Aluminium radiopacity standards for dentistry: an international survey", J Dent, 27, pp.73~78 (1999)
- Duarte MA, "pH and calcium ion release of 2 root-end filling materials", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.345~347 (2003)
- Camilleri J, "The chemical constitution and biocompatibility of accelerated Portland cement for endodontic use", Int Endod J, 38, pp.834~842 (2005)
- Tveit AB, "Radiographic diagnosis of caries and marginal defects in connection with radiopaque composite fillings", Dent Mater, 2, pp.159~162 (1986)
- Akerboom HB, "Radiopacity of posterior composite resins, composite resin luting cements, and glass ionomer lining cements", J Prosthet Dent, 70, pp.351~355 (1993)
- el-Mowafy OM, "Radiopacity of direct ceramic inlay restoratives", J Dent, 19, pp.366~368 (1991)
- el-Mowafy OM, "Radiopacity of resinbased inlay luting cements", Oper Dent, 19, pp.11~15 (1994)
- Stecke J, "Alternative X-ray filters for an intra-oral digital radiographic system", Dentomaxillofac Radiol, 41, pp.361~366 (2012)
- Johnson WW, "Composite microfiller content and its effect on fracture toughness and diametral tensile strength", Dent Mater, 9, pp.95~98 (1993)
- Fonseca RB, "Radiodensity of enamel and dentin of human, bovine and swine teeth", Arch Oral Biol, 49, pp.919~922 (2004)
