Determination of trace boron in steels by prompt gamma-ray activation analysis
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A trace amount of boron in steel significantly influences its mechanical and physical properties. A prompt gamma ray activation analysis (PGAA) method is used to measure boron in low alloy steel samples of KRISS 101-01-C21~C26. NIST SRMs of 362, 364, 1761 and 1767 serve as the control standards to validate the measurement method. The measured values of the NIST SRMs are consistent with their certified values within the expected uncertainties, except for that of NIST SRM 362. Experimental uncertainties are evaluated according to the guidelines given by the International Organization for Standardization (ISO). The expanded uncertainties are calculated with a coverage factor of 2, at approximately 95% confidence level. The calculated relative expanded uncertainties of boron mass fractions are between 3% and 7% at the mg/kg level. The results are compared with the results measured by the solvent extraction-inductively coupled optical emission spectrometry (ICP/OES) method.
Abstract
A trace amount of boron in steel significantly influences its mechanical and physical properties. A prompt gamma ray activation analysis (PGAA) method is used to measure boron in low alloy steel samples of KRISS 101-01-C21~C26. NIST SRMs of 362, 364, 1761 and 1767 serve as the control standards to validate the measurement method. The measured values of the NIST SRMs are consistent with their certified values within the expected uncertainties, except for that of NIST SRM 362. Experimental uncertainties are evaluated according to the guidelines given by the International Organization for Standardization (ISO). The expanded uncertainties are calculated with a coverage factor of 2, at approximately 95% confidence level. The calculated relative expanded uncertainties of boron mass fractions are between 3% and 7% at the mg/kg level. The results are compared with the results measured by the solvent extraction-inductively coupled optical emission spectrometry (ICP/OES) method.
참고문헌 (23)
- E. Yasuhara, , ISIJ Int., 34, pp.99~107 (1994)
- S. Okubo, "Nihon Kikaku Kyoukai" (1999), Tokyo, Japan
- D. Michael, , At. Spectrosc., 17, pp.128~132 (1996)
- K. Yamada, , Anal. Sci., 9, pp.385~390 (1993)
- K. Fujimoto, , Tetsu-tohagane, 85, pp.114~118 (1999)
- A. G. Coedo, , Anal. Chem., 68, pp.991~996 (1996)
- ChangJ.Park, "Determination of Boron in Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation", Bulletin of the Korean Chemical Society, 23(11), pp.11~1544 (2002), 대한화학회
- N. Uehara, , Anal. Sci., 17, pp.1421~1424 (2001)
- J. E. Riley, Jr, , J. Radioanal. Nucl. Chem., 109, pp.109~115 (1987)
- S. Baechler, , Nucl. Instr. and Meth, A488, pp.410~413 (2002)
- S. H. Byun, , Nucl. Instr. and Meth., B213, pp.535~539 (2004)
- "Certificate of Analysis, Standard Reference Material 951 Boric Acid" (1969), National Bureau of Standards, Washington, D.C.
- M. D. Dyar, , Geostandards Newsletter, 25, pp.441~463 (2001)
- C. Yonezawa, , J. Radioanal. Nucl. Chem., 239, pp.571~575 (1999)
- D. L. Anderson, , Fresenius J. Anal. Chem., 338, pp.554~558 (1990)
- R. L. Paul, , Analyst, 130, pp.99~103 (2005)
- Y. Sakai, , Nucl. Instr. and Meth., A353, pp.699~701 (1994)
- R. F. Fleming, , Int. J. Appl. Radiat. Isot., 33, pp.1263~1268 (1982)
- K. Debertin, "Gamma- and X-Ray Spectrometry with Semiconductor Detectors" (1988), Elsevier Science Publisher B.V., Amsterdam
- A. Wyttenbach, , J. Radioanal. Nucl. Chem., 8, pp.335~343 (1971)
- "Guide to the Expression of Uncertainty in Measurement" (1993), ISO, Switzerland
- Report of Analysis 86, "551", NUCLM, R. M. Lindstrom, pp.Gaithersburg, MD, USA, 1986[DOI]
- I. Mills, "Quantities, Units and Symbols in Physical Chemistry" (1993), Blackwell Science, Victoria, Australia