고정성 보철물의 적합도에 대한 실험적 평가방법
In vitro evaluation methods on adaptation of fixed dental prosthesis
1
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
임상적으로 고정성보철물의 적합도는 성공적인 수복을 위해 필수적인 요소이다. 보철물의 적합도는 크게 변연적합도와 내면적합도로 분류되며, 이를 평가하기 위한 방법으로는 현미경 변연 측정법, 절단면 측정법, 실리콘 복제법, 3차원 스캔데이터 중첩법, 무게 측정법, 마이크로 CT 측정법 등 다양한 방법들이 소개되고 있다. 이에 본 연구에서는 기존의 문헌들을 바탕으로 각 방법들의 장, 단점을 비교분석함으로써 디지털환경에서 보다 편리하고 정확한 측정법을 제시하고자 한다.
Abstract
Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.
참고문헌 (53)
- 김민영, "치과병원 내원환자의 만족도 조사분석", 대한치과보철학회지, 46(1), pp.65~82 (2008), 대한치과보철학회
- Rekow ED, "High-technology innovations-and limitations-for restorative dentistry", Dent Clin North Am, 37, pp.513~524 (1993)
- Hung SH, "Marginal fit of porcelain- fused-to-metal and two types of ceramic crown", J Prosthet Dent, 63, pp.26~31 (1990)
- Schwartz NL, "Unserviceable crowns and fixed partial dentures:life-span and causes for loss of serviceability", J Am Dent Assoc, 81, pp.1395~1401 (1970)
- Grasso JE, "Effect of restoration quality on periodontal health", J Prosthet Dent, 53, pp.14~19 (1985)
- Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
- Suárez MJ, "Comparison of the marginal fit of Procera ALLCeram crowns with two finish lines", Int J Prosthodont, 16, pp.229~232 (2003)
- Pelekanos S, "Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings", Eur J Esthet Dent, 4, pp.278~292 (2009)
- Christensen GJ, "Marginal fit of gold inlay casting", J Prosthet Dent, 16, pp.297~305 (1966)
- Sorensen SE, "Gingival and alveolar bone reaction to marginal fit of subgingival crown margins", Scand J Dent Res, 94, pp.109~114 (1986)
- Assif D, "The flow of zinc phosphate cement under a full-coverage restoration and its effect on marginal adaptation according to the location of cement application", Quitessence Int, 18, pp.765~774 (1987)
- McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
- McLean JW, "Polycarboxylate cements. Five years’experience in general practice", Br Dent J, 132, pp.9~15 (1972)
- Grey NJ, "In vitro comparison of conventional crowns and a new all-ceramic system", J Dent, 21, pp.47~51 (1993)
- Tuntiprawon M, "The effect of cement thickness on the fracture strength of all-ceramic crowns", Aust Dent J, 40, pp.17~21 (1995)
- Jorgensen KD, "The relationship between the film thickness of zinc phosphate cement and the retention of veneer crowns", Acta Odontol Scand, 26, pp.169~175 (1968)
- Passon C, "The effect of multiple layers of die-spacer on crown retention", Oper Dent, 17, pp.42~49 (1992)
- Sorensen JA, "Interfacial gaps of resin cemented ceramic inlays", Eur J Oral Sci, 103, pp.116~120 (1995)
- Molin MK, "Influence of film thickness on joint bend strength of a ceramic", resin composite joint, 1996, pp.12, 245~249
- Kunii J, "Effect of sintering on the marginal and internal fit of CAD", CAM-fabricated zirconia frameworks, 2007, pp.26, 820~826
- Mitchell CA, "Nondestructive, in vitro quantification of crown margins", J Prosthet Dent, 85, pp.575~584 (2001)
- Shearer B, "Influence of marginal configuration and porcelain addition on the fit on In-Ceram crowns", Biomaterials, 17, pp.1891~1895 (1996)
- Rahme HY, "In vitro evaluation of “replica technique” in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
- Tsitrou EA, "Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD", CAM, 2007, pp.35, 68~73
- Tjan AH, "Marginal accuracy of complete crowns made from alternative casting alloys", J Prosthet Dent, 66, pp.157~164 (1991)
- Stappert CF, "Marginal adaptation of three-unit fixed partial dentures constructed from pressed ceramic systems", Br Dent J, 196, pp.766~770 (2004)
- Wolfart S, "Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation", Int J Prosthodont, 16, pp.587~592 (2003)
- Okutan M, "Fracture load and marginal fit of shrinkage-free ZrSiO4 allceramic crowns after chewing simulation", J Oral Rehabil, 33, pp.827~832 (2006)
- Att W, "Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses", J Prosthet Dent, 101, pp.239~247 (2009)
- Tinschert J, "Marginal fit of alumina- and zirconia-based fixed partial dentures produced by a CAD", CAM system, 2001, pp.26, 367~374
- Beschnidt SM, "Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth", J Oral Rehabil, 26, pp.582~593 (1999)
- Kern M, "Marginal fit of restorations before and after cementation in vivo", Int J Prosthodont, 6, pp.585~591 (1993)
- Assif D, "Comparison of methods of clinical evaluation of the marginal fit of complete cast gold crowns", J Prosthet Dent, 54, pp.20~24 (1985)
- Groten M, "Determination of the minimum number of marginal gap measurements required for practical in-vitro testing", J Prosthet Dent, 83, pp.40~49 (2000)
- Luthardt RG, "An innovative method for evaluation of the 3-D internal fit of CAD", CAM crowns fabricated after direct optical versus indirect laser scan digitizing, 2004, pp.17, 680~685
- Moldovan O, "Three-dimensional fit of CAD", CAM-made zirconia copings, 2011, pp.27, 1273~1278
- 김기백, "Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and threedimensional replica techniques", The Journal of Advanced of Prosthodontics, 5(2), pp.179~186 (2013), 대한치과보철학회[DOI]
- Coli P, "Fit of a new pressure-sintered zirconium dioxide coping", Int J Prosthodont, 17, pp.59~64 (2004)
- Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicon replica method", J Oral Rehabil, 35, pp.116~122 (2008)
- 김재홍, "인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적안정성 평가", 치위생과학회지, 14(1), pp.15~21 (2014), 한국치위생과학회
- DeLong R, "Accuracy of a system for creating 3D computer models of dental arches", J Dent Res, 82, pp.438~442 (2003)
- Bae SY, "Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia", J Prosthodont Res, 61, pp.106~112 (2017)
- Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)
- 김기백, "치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성연구: 3차원 중첩 분석", 치위생과학회지, 14(2), pp.94~100 (2014), 한국치위생과학회
- Nakamura T, "Marginal and internal fit of Cerec 3 CAD", CAM all-ceramic crowns, 2003, pp.16, 244~248
- Lee KB, "Marginal and internal fit of all-ceramic crowns fabricated with two different CAD", CAM systems, 2008, pp.27, 422~426
- Colpani JT, "Evaluation of marginal and internal fit of ceramic crown copings", Dent Mater, 29, pp.174~180 (2013)
- Borba M, "Adaptation of all-ceramic fixed partial dentures", Dent Mater, 27, pp.1119~1126 (2011)
- Seo D, "The effect of preparation designs on the marginal and internal gaps in Cerec3partial ceramic crowns", J Dent, 37, pp.374~382 (2009)
- Alfaro DP, "Assessment of the internal fit of lithium disilicate crowns using micro-CT", J Prosthodont, 24, pp.381~386 (2015)
- Rungruanganunt P, "Two imaging techniques for 3D quantification of precementation space for CAD", CAM crowns, 2010, pp.38, 995~1000
- Kim JH, "Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT", J Prosthet Dent, 116, pp.551~557 (2016)
- Nawafleh NA, "Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs:a literature review", J Prosthodont, 22, pp.419~428 (2013)
