Purpose: This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. Materials and Methods: The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. Results: For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. Conclusion: These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.

Abstract

Purpose: This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint. Materials and Methods: The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°. Results: For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions. Conclusion: These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.

관련 논문AI추천

The Effect of Tibial Posterior Slope on Contact Force and Ligaments Stresses in Posterior-Stabilized Total Knee Arthroplasty-Explicit Finite Element AnalysisHwa-Yong Lee, Kwan-Kyu Park, Kyoung-Tak Kang, Sung-Hwan Kim, Sung Jae Kim대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제2호Internal rotational patellar resection and patella alta induced patellar maltracking in total knee arthroplasty: intraoperative measurement of the patellofemoral pressureHideki Murakami, Hiroo Shiraga, Masahiro Nozaki, Sakurako Kato, Sanshiro Yasuma, Takuya Usami, Yuji Joyo, Yuko Waguri‑Nagaya, Yusuke Hattori대한슬관절학회 · Knee Surgery and Related Research2024 · 제36권 반치환 슬관절의 설계 평가를 위한 굴곡각도에 따른곡률반경과 접촉응력의 상관도 분석김재원, 김정성, 유의식, 이용경, 임도형, 정태곤대한의용생체공학회 · 의공학회지2016 · 제37권 제6호Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing ConditionBeom Koo Lee, Byung Kak Kim, Jae Ang Sim, Won Seok Oh, Yong Seuk Lee대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제2호Tibiofemoral articulation and axial tibial rotation of the knee after a cruciate retaining total knee arthroplastyChaochao Zhou, Guoan Li, Hany Bedair, Jia Yu, Sophia Li, Timothy Foster대한슬관절학회 · Knee Surgery and Related Research2024 · 제36권 Increased kinematic changes in ascending compared with descending biplanar cut in open wedge high tibial osteotomy—a multibody simulationBoris Michael Holzapfel, Julian Fürmetz, Julius Watrinet, Klaus Radermacher, Lennart Schroeder, Maximilian Jörgens, Sonja Ehreiser, Wolfgang Böcker대한슬관절학회 · Knee Surgery and Related Research2024 · 제36권

이 간행물의 다른 논문 (7건)