본문 바로가기
KERD
논문KCI 등재

Histological analysis of explanted implant-bone interface: a case report

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Osseointegration has been reported to be a dynamic process in which the alveolar bone comes in direct contact with the implant. Various methods were tried to evaluate degree of osseointegration and the measurement of bone-implant contact (BIC) have been commonly used among them. To properly assess the BIC, only histologic analysis is available. However, few studies evaluated BIC of successfully osseointegrated implants in humans. Thus, this is a unique opportunity when implants should be explanted due to inappropriate positioning of implant, presence of pain or sensory disturbance, or broken screw or fixture. This report presents a case of the implant underwent 3-year functional load and a histologic analysis after the fixture fracture. The histomorphometric analysis revealed 53.1% of BIC measured along the whole implant and 70.9% measured only in subcrestal area, respectively. In the present study, although the implant was fractured, a high degree of BIC was observed.

Abstract

Osseointegration has been reported to be a dynamic process in which the alveolar bone comes in direct contact with the implant. Various methods were tried to evaluate degree of osseointegration and the measurement of bone-implant contact (BIC) have been commonly used among them. To properly assess the BIC, only histologic analysis is available. However, few studies evaluated BIC of successfully osseointegrated implants in humans. Thus, this is a unique opportunity when implants should be explanted due to inappropriate positioning of implant, presence of pain or sensory disturbance, or broken screw or fixture. This report presents a case of the implant underwent 3-year functional load and a histologic analysis after the fixture fracture. The histomorphometric analysis revealed 53.1% of BIC measured along the whole implant and 70.9% measured only in subcrestal area, respectively. In the present study, although the implant was fractured, a high degree of BIC was observed.

참고문헌 (20)

  1. Iezzi G, "Periimplant bone response in human-retrieved, clinically stable, successful, and functioning dental implants after a long-term loading period: a report of 17 cases from 4 to 20 years", Implant Dent, 25, pp.380~386 (2016)
  2. Cordioli G, "Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia", Int J Oral Maxillofac Implants, 15, pp.668~674 (2000)
  3. Sakakura CE, "Influence of cyclosporin A therapy on bone healing around titanium implants: a histometric and biomechanic study in rabbits", J Periodontol, 74, pp.976~981 (2003)
  4. Degidi M, "Bone contact around acid-etched implants: a histological and histomorphometrical evaluation of two human-retrieved implants", J Oral Implantol, 29, pp.13~18 (2003)
  5. Brunel G, "Histologic analysis of a fractured implant: a case report", Int J Periodontics Restorative Dent, 20, pp.520~526 (2000)
  6. Degidi M, "Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface", Clin Implant Dent Relat Res, 4, pp.110~114 (2002)
  7. Sennerby L, "Structure of the bone-titanium interface in retrieved clinical oral implants", Clin Oral Implants Res, 2, pp.103~111 (1991)
  8. Johansson CB, "Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium", Biomaterials, 11, pp.277~280 (1990)
  9. Donath K, "A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique", J Oral Pathol, 11, pp.318~326 (1982)
  10. Shah FA, "The bone-implant interface - nanoscale analysis of clinically retrieved dental implants", Nanomedicine, 10, pp.1729~1737 (2014)
  11. Mangano FG, "Early bone response to dual acid-etched and machined dental implants placed in the posterior maxilla: a histologic and histomorphometric human study", Implant Dent, 26, pp.24~29 (2017)
  12. Schwartz Z, "Implant surface characteristics modulate differentiation behavior of cells in the osteoblastic lineage", Adv Dent Res, 13, pp.38~48 (1999)
  13. Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs", J Biomed Mater Res, 25, pp.889~902 (1991)
  14. Hayakawa T, "A histologic and histomorphometric evaluation of two types of retrieved human titanium implants", Int J Periodontics Restorative Dent, 22, pp.164~171 (2002)
  15. Schwarz MS, "Mechanical complications of dental implants", Clin Oral Implants Res, 11, pp.156~158 (2000)
  16. Rangert B, "Bending overload and implant fracture: a retrospective clinical analysis", Int J Oral Maxillofac Implants, 10, pp.326~334 (1995)
  17. Balshi TJ, "Two-implant-supported single molar replacement: interdental space requirements and comparison to alternative options", Int J Periodontics Restorative Dent, 17, pp.426~435 (1997)
  18. Steflik DE, "Light microscopic and scanning electron microscopic analyses of dental implants retrieved from humans", J Oral Implantol, 20, pp.8~24 (1994)
  19. Piattelli A, "Hollow implants retrieved for fracture: a light and scanning electron microscope analysis of 4 cases", J Periodontol, 69, pp.185~189 (1998)
  20. Eckert SE, "Analysis of incidence and associated factors with fractured implants: a retrospective study", Int J Oral Maxillofac Implants, 15, pp.662~667 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (8건)