Non-invasive continuous blood pressure monitoring using the ClearSight system for pregnant women at high risks of post-partum hemorrhage: comparison with invasive blood pressure monitoring during cesarean section

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류산부인과학

초록

Objective: This study aimed to investigate the accuracy and precision of continuous, non-invasive blood pressure obtained using the ClearSight system by comparing it with invasive arterial blood pressure, and to assess the hemodynamic changes using invasive methods and the ClearSight system in patients undergoing cesarean section. Methods: Arterial pressure was measured invasively with an intra-arterial catheter and non-invasively using the ClearSight system during cesarean section in patients with placenta previa or placenta accreta. Blood pressure measurements obtained using these two means were then compared. Results: Total 1,277 blood pressure measurement pairs were collected from 21 patients. Under Bland-Altman analysis, the ClearSight system demonstrated an acceptable accuracy with a bias and standard deviation of 8.8±13.4 mmHg for systolic blood pressure, -6.3±7.1 mmHg for diastolic blood pressure, and -2.7±8.0 mmHg for median blood pressure. Cardiac index levels were significantly elevated during fetal delivery and 5 minutes after placental removal, and systemic vascular resistance index levels were significantly decreased during fetal delivery and 40 minutes after placental removal. Conclusion: In patients undergoing cesarean section, the ClearSight system showed excellent accuracy and precision compared to that of the currently used invasive monitoring system.

Abstract

Objective: This study aimed to investigate the accuracy and precision of continuous, non-invasive blood pressure obtained using the ClearSight system by comparing it with invasive arterial blood pressure, and to assess the hemodynamic changes using invasive methods and the ClearSight system in patients undergoing cesarean section. Methods: Arterial pressure was measured invasively with an intra-arterial catheter and non-invasively using the ClearSight system during cesarean section in patients with placenta previa or placenta accreta. Blood pressure measurements obtained using these two means were then compared. Results: Total 1,277 blood pressure measurement pairs were collected from 21 patients. Under Bland-Altman analysis, the ClearSight system demonstrated an acceptable accuracy with a bias and standard deviation of 8.8±13.4 mmHg for systolic blood pressure, -6.3±7.1 mmHg for diastolic blood pressure, and -2.7±8.0 mmHg for median blood pressure. Cardiac index levels were significantly elevated during fetal delivery and 5 minutes after placental removal, and systemic vascular resistance index levels were significantly decreased during fetal delivery and 40 minutes after placental removal. Conclusion: In patients undergoing cesarean section, the ClearSight system showed excellent accuracy and precision compared to that of the currently used invasive monitoring system.

참고문헌 (36)

  1. 이경주, "Maternal, infant, and perinatal mortality statistics and trends in Korea between 2009 and 2017", Obstetrics & Gynecology Science, 63(5), pp.623~630 (2020), 대한산부인과학회[DOI]
  2. 김호연, "Secular trends in cesarean sections and risk factors in South Korea (2006–2015)", Obstetrics & Gynecology Science, 63(4), pp.440~447 (2020), 대한산부인과학회[DOI]
  3. Dilla AJ, "Clinical validation of risk stratification criteria for peripartum hemorrhage", Obstet Gynecol, 122, pp.120~126 (2013)
  4. Cannesson M, "Hemodynamic monitoring and management in patients undergoing high risk surgery : a survey among North American and European anesthesiologists", Crit Care, 15, pp.R197~ (2011)
  5. Huygh J, "Hemodynamic monitoring in the critically ill : an overview of current cardiac output monitoring methods", F1000Res, 5, pp.2855~ (2016)
  6. Brzezinski M, "Radial artery cannulation : a comprehensive review of recent anatomic and physiologic investigations", Anesth Analg, 109, pp.1763~1781 (2009)
  7. Bartels K, "Blood pressure monitoring for the anesthesiologist : a practical review", Anesth Analg, 122, pp.1866~1879 (2016)
  8. Fischer MO, "Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery", Br J Anaesth, 109, pp.514~521 (2012)
  9. Hofhuizen C, "Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy", J Crit Care, 29, pp.161~165 (2014)
  10. Juri T, "Impact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery : a randomized-controlled study", J Anesth, 32, pp.822~830 (2018)
  11. Jauniaux E, "Placenta praevia and placenta accreta : diagnosis and management : green-top guideline No. 27a", BJOG, 126, pp.e1~e48 (2019)
  12. Clark CE, "Association of a difference in systolic blood pressure between arms with vascular disease and mortality : a systematic review and meta-analysis", Lancet, 379, pp.905~914 (2012)
  13. Ward CR, "Avoiding an incision through the anterior previa at cesarean delivery", Obstet Gynecol, 102, pp.552~554 (2003)
  14. Tahara M, "The ward technique for anterior placenta previa", Arch Gynecol Obstet, 303, pp.1375~1376 (2021)
  15. Hamuro A, "On-site hemostatic suturing technique for uterine bleeding from placenta previa and subsequent pregnancy", Arch Gynecol Obstet, 292, pp.1181~1182 (2015)
  16. Eeftinck Schattenkerk DW, "Nexfin noninvasive continuous blood pressure validated against riva-rocci", korotkoff, 2009, pp.22, 378~383
  17. Sumiyoshi M, "Accuracy of the ClearSight™ system in patients undergoing abdominal aortic aneurysm surgery", J Anesth, 33, pp.364~371 (2019)
  18. Ganzevoort W, "Plasma volume and blood pressure regulation in hypertensive pregnancy", J Hypertens, 22, pp.1235~1242 (2004)
  19. Eyeington CT, "Non-invasive continuous haemodynamic monitoring and response to intervention in haemodynamically unstable patients during rapid response team review", Resuscitation, 143, pp.124~133 (2019)
  20. Heusdens JF, "Validation of non-invasive arterial pressure monitoring during carotid endarterectomy", Br J Anaesth, 117, pp.316~323 (2016)
  21. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 1, pp.307~310 (1986)
  22. Kim SH, "Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure : a systematic review and meta-analysis", Anesthesiology, 120, pp.1080~1097 (2014)
  23. Ueland K, "Maternal cardiovascular dynamics. II. Posture and uterine contractions", Am J Obstet Gynecol, 103, pp.1~7 (1969)
  24. Stover JF, "Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients", BMC Anesthesiol, 9, pp.6~ (2009)
  25. Hohn A, "Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients", Br J Anaesth, 111, pp.178~184 (2013)
  26. SeifiA, "Usage of Swan-Ganz catheterization during the past 2 decades in United States", J Crit Care, 35, pp.213~214 (2016)
  27. Monnet X, "Transpulmonary thermodilution : advantages and limits", Crit Care, 21, pp.147~ (2017)
  28. Cholley BP, "Esophageal Doppler : noninvasive cardiac output monitor", Echocardiography, 20, pp.763~769 (2003)
  29. Truijen J, "Noninvasive continuous hemodynamic monitoring", J Clin Monit Comput, 26, pp.267~278 (2012)
  30. Ameloot K, "Nexfin noninvasive continuous hemodynamic monitoring : validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients", ScientificWorldJournal, 2013, pp.519080~ (2013)
  31. Broch O, "A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery", Anaesthesia, 67, pp.377~383 (2012)
  32. Chen G, "Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler", J Clin Anesth, 24, pp.275~283 (2012)
  33. Bubenek-Turconi SI, "Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers : a comparison with intermittent thermodilution cardiac output", Anesth Analg, 117, pp.366~372 (2013)
  34. Critchley LA, "A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques", J Clin Monit Comput, 15, pp.85~91 (1999)
  35. Romagnoli S, "Accuracy of invasive arterial pressure monitoring in cardiovascular patients : an observational study", Crit Care, 18, pp.644~ (2014)
  36. McLeod G, "Maternal haemodynamics at elective caesarean section : a randomised comparison of oxytocin 5-unit bolus and placebo infusion with oxytocin 5-unit bolus and 30-unit infusion", Int J Obstet Anesth, 19, pp.155~160 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (10건)