미세 유체장치 내에서 Poly(Ethylene Glycol)과 Dextran 용액의 상 형성 특성 연구
Phase-Separation Properties of Poly(Ethylene Glycol) And Dextran Solutions In Microfluidic Device
0
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Fluidic conditions for the separation of phases were surveyed in a microfluidic aqueous two-phase extraction system. The infusion ratio between polyethylene glycol (PEG) and dextran solution defines the concentrations of each polymer in micro-channel, which determine the phase-separation. The appropriate ratio between PEG (M.W. 8000, 10%, w/v) and dextran T500 (M.W. 500000, 5%, w/v) in order to perform the separation of phases of both polymers was observed as changing the mixed ratio of both polymers. Based on the fluidic conditions, stable two-phase solutions were obtained within 4% to 8% and 3% to 1% of PEG and dextran, respectively. In addition, the characteristics of the two-phase were discussed. The separation technique studied in the paper can be applied for the implementation of a lab-on-a chip which can detect various biological entities such cells, bacterium, and virus in an integrated manner using built in a biosensor inside the chip.
참고문헌 (23)
- A. Manz, "Planar chips technology for miniaturization and integration of separation techniques into monitoring systems Capillary electrophoresis on a chip", 593, pp.243~252 (1992)
- D.J. Harrison, "Capillary electrophoresis and sample injection systems integrated on a planar glass chip", 64
- A.G. Hadd, "Microchip device for performing enzyme assays", 69, pp.3407~3412 (1997)
- G.M. Whitesides, "The origins and the future of microfluidics", 442, pp.368~373 (2006)
- J.C. Yoo, "A high performance microfluidic system integrated with the micropump and microvalve on the same substrate", 83, pp.1684~1687 (2006)
- V. Hessel, "Micromixers a review on passive and active mixing principles", 60, pp.2479~2501 (2005)
- W.R. Vandaveer IV, "Recent developments in amperometric detectionfor microchip capillary electrophoresis", 23, pp.3667~3677 (2002)
- I. Rodriguez, "Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin G", 781, pp.287~293 (1997)
- E.K. Zholkovskij, "Hydrodynamic dispersion due to combined pressure-driven and electroosmotic flow through microchannels with a thin double layer", 76, pp.2708~2718 (2004)
- F.E. Regnier, "Chromatography and electrophoresis on chips critical elements of future integrated microfluidic analytical systems for life science", 17, pp.101~106 (1999)
- K. Choi, "Liquid-Phase microextraction preconcentration electrophoresis", 76, pp.855~858 (2004)
- C. Malhaire, "Mechanical characterizationand reliability study of bistable SiO2", Si membranes for microfluidic applications, 2002., pp.99, 216~219
- G.M. Zijlstra, "Extractive bioconversions in aqueous two-phase systems", 9, pp.171~176 (1998)
- G. Johansson, "Highly Selective Separations in Biotechnology" (1994)
- H. Walter, "Methods in Enzymology" (1994), Academic Press Inc.
- J.F. Hamel, "Modeling and Applications of Downstream Processing A survey of innovative strategies Recovery and purification of biological products" (1988)
- H. Hustedt, "Applications of Phase Partitioning in Biotechnology Partitioning in Aqueous Two- Phase Systems and applications to biotechnology" (1985), Academic Press Inc. Orlando
- M. Yamada, "Continuous cell partitioning using an aqueous two-phase flowsystem in micro- fluidic devices", 87, pp.489~494 (2004)
- K.H. Nam, "Continuous-flow fractionation of animal cells in micro- fluidic device using aqueous two-phase extraction", 7(3), pp.189~195 (2005)
- C.S. Effenhauser, "Integrated capillary electrophoresis on flexible silicone micr- odevices: analysis of DNA restriction fragments and detection of single DNA molecules on microchips", 69, pp.3451~3457 (1997)
- D.C. Duffy, "Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)", 70, pp.4974~4984 (1998)
- Y. Shibusawa, "Purification of alcohol dehydrogenase from bovine liver crude extract by dyeligand affinity counter-current chromatography", 799, pp.239~244 (2004)
- S. Ghosh, "Evaluation of an alternative source of dextran as a phase forming polymer for aqueous two-phase extractive system", 21, pp.241~252 (2004)