뇌파 기반 실시간 뇌활동 모니터링 시스템의 타당성 조사
Feasibility Study of EEG-based Real-time Brain Activation Monitoring System
1
조회
0
다운로드
1
인용
0
참고문헌
초록
Abstract
Spatiotemporal changes of brain rhythmic activity at a certain frequency have been usually monitored in real time using scalp potential maps of multi-channel electroencephalography(EEG) or magnetic field maps of magnetoencephalography(MEG). In the present study, we investigate if it is possible to implement a real-time brain activity monitoring system which can monitor spatiotemporal changes of cortical rhythmic activity on a subject's cortical surface, neither on a sensor plane nor on a standard brain model, with a high temporal resolution. In the suggested system, a frequency domain inverse operator is preliminarily constructed, considering the individual subject's anatomical information, noise level, and sensor configurations. Spectral current power at each cortical vertex is then calculated for the Fourier transforms of successive sections of continuous data, when a single frequency or a particular frequency band is given. An offline study which perfectly simulated the suggested system demonstrates that cortical rhythmic source changes can be monitored at the cortical level with a maximal delay time of about 200 ms, when 18 channel EEG data are analyzed under Pentium4 3.4GHz environment. Two sets of artifact-free, eye closed, resting EEG data acquired from a dementia patient and a normal male subject were used to show the feasibility of the suggested system. Factors influencing the computational delay are investigated and possible applications of the system are discussed as well.
참고문헌 (34)
- O. Jensen, "A new method to identify multiple sources of oscillatory sctivity from magnetoencephalographic data", 15, pp.568~574 (2002)
- S. Salenius, "Reactivity of magnetic parieto-occipital alpha rhythm during visual imagery", 95, pp.453~462 (1995)
- R. Salmelin, "Spatiotemporal characteristics of sens- orimotor neuromagnetic rhythms related to thumb movement", 60, pp.537~550 (1994)
- T. Gruber, "Selective visual-spatial attention alters induced gamma band responses in the human", 110, pp.2074~2085 (1999)
- J. Kaiser, "Dynamics of gamma-band activity in human magnetoencephalogram during auditory pattern working memory", 20, pp.816~827 (2003)
- W.H. Miltner, "Coherence of gamma-band EEG activity as a basis for associative learningCoherence of gamma-band EEG activity as a basis for associative learning", 397, pp.434~436 (1999)
- J.S. Kwon, "Gamma frequency-range abnormalities to auditory stimulation in schizophrenia", 56, pp.1001~1005 (1999)
- D. Osipova, "Altered generation of spontaneous oscillations in Alzheimer's disease", 27, pp.835~841 (2005)
- A. Kubler, "Brain-computer communication: Unlocking the locked", 127, pp.358~375 (2001)
- M. Congedo, "Low-Resolution elec- tromagnetic tomography neurofeedback", 12, pp.387~397 (2004)
- R. Salmelin, "Single word reading in developmental stutterers and fluent speakers", 123, pp.1184~1202 (2000)
- J. Gross, "Dynamic imaging of coherent sources Studying neural interactions in the human brain", 98, pp.694~699 (2001)
- O. Jensen, "A new method to identify multiple sources of oscillatory activity from magnetoencephalographic data", 15, pp.568~574 (2002)
- F.H. Lin, "Spectral spatiotemporal imaging of cortical oscillations and interations in the human brain", 23, pp.582~595 (2004)
- M. Congedo, "Low-resolution electro- magnetic tomography neurofeedback", 12, pp.387~397 (2004)
- M. Congedo, "Subspace projection filters for real-time brain electromagnetic imaging", 53, pp.1624~1634 (2006)
- R.D. Pascual-Marqui, "downloadable at http"
- B. He, "Electric dipole tracing in the brain by means of the boundary element method and its accuracy", 34, pp.406~414 (1987)
- M.S. Hmlinen, "Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data", 36, pp.165~171 (1989)
- J. Haueisen, "Influence of tissue resistivities on neuromagnetic fields and electric potentials studied with a finite element model of the head", 44, pp.727~735 (1997)
- T.F. Oostendorp, "The conductivity of the human skull results of in vivo and in vitro measurements", 47, pp.1487~1492 (2000)
- C.H. Im, "BioEST A free software to reconstruct EEG", MEG source distribution information can be found at http, ~
- A.M. Dale, "Improved localization of cortical activity by combining EEG and MEG with MRI surface reco- nstruction", 5, pp.162~176 (1993)
- W.E. Kincses, "Modeling extended sources of event-related potentials using anatomical and physiological constraints", 8, pp.182~193 (1999)
- A.M. Dale, "Dynamic Statistical Parametric Mapping : Combining fMRI and MEG for High-Resolution Imaging of Cortical Activity", 26, pp.55~67 (2000)
- C. Babiloni, "Linear inverse source estimate of combined EEG and MEG data related to voluntary movements", 14, pp.197~209 (2001)
- S. Baillet, "Evaluation of inverse methods and head models for EEG source localization using a human skull phantom", 46, pp.77~96 (2001)
- A.K. Liu, "Spatiotemporal imaging of human brain activity using functional MRI constrained magnetoencephalography data : Monte Carlo simulations", 95, pp.8945~8950 (1998)
- A.M. Dale, "Cortical surface-based analysis I. segmentation and surface reconstruction", 9, pp.179~194 (1999)
- A.K. Liu, "Monte Carlo simulation studies of EEG and MEG localization accuracy", 16, pp.47~62 (2002)
- R. Salmelin, "Characterization of spontaneous MEG rhythms in healthy adults", 91, pp.237~248 (1994)
- S. Vanni, "Modulation of the parieto- occipital alpha rhythm during object detection", 17, pp.7141~7147 (1997)
- B. Kamousi, "Classification of motor imagery by means of cortical current density estimation and von neumann entropy for brain-computer interface applications" (2007), J. Neural Eng., in press
- B. Kamousi, "Classification of motor imagery tasks for brain-computer interface applications by means of two equivalent dipoles analysis", 13, pp.166~171 (2005)
