Wrist joints consist of irregularly shaped carpal bones and other complicated structures. Thus, evaluating the motion of a wrist joint is a challenging task. In this study, we used an infrared camera to perform a kinematic analysis of a dart-throwing motion. We measured the difference between the movement of a normal wrist and constrained wrist (wrist with a wrist glove) in the dart-throwing motion with thirty six healthy participants. We measured the ulna flexion - radial extension motion using the attached passive marker and analyzed it using Polygon software and SPSS. The pitch and yaw motions with a glove was bigger than the ones without a glove by 20 and 15 degrees,respectively. On the other hand, the roll motion without a glove was bigger than the one with a glove by 7 degree. Wilcoxon signed rank test (p < 0.05) confirmed that there are significant differences between the motion with and without a glove. It was found that the magnitude of the pitch and yaw motion with a constrained wrist joint toward radial extension in dart-throwing motion is smaller than the one with a normal wrist joint. However, a normal wrist joint showed a bigger movement in the roll direction.

Abstract

Wrist joints consist of irregularly shaped carpal bones and other complicated structures. Thus, evaluating the motion of a wrist joint is a challenging task. In this study, we used an infrared camera to perform a kinematic analysis of a dart-throwing motion. We measured the difference between the movement of a normal wrist and constrained wrist (wrist with a wrist glove) in the dart-throwing motion with thirty six healthy participants. We measured the ulna flexion - radial extension motion using the attached passive marker and analyzed it using Polygon software and SPSS. The pitch and yaw motions with a glove was bigger than the ones without a glove by 20 and 15 degrees,respectively. On the other hand, the roll motion without a glove was bigger than the one with a glove by 7 degree. Wilcoxon signed rank test (p < 0.05) confirmed that there are significant differences between the motion with and without a glove. It was found that the magnitude of the pitch and yaw motion with a constrained wrist joint toward radial extension in dart-throwing motion is smaller than the one with a normal wrist joint. However, a normal wrist joint showed a bigger movement in the roll direction.

참고문헌 (35)

  1. R. P. Calfee, "Simulated radioscapholunate fusion alters carpal kinematics while preserving dart-thrower's motion", The Journal of hand surgery, 33, pp.503~510 (2008)
  2. A. Minami, "Limited wrist fusions", The Journal of hand surgery, 13, pp.660~667 (1988)
  3. J. D. Krakauer, "Surgical treatment of scapholunate advanced collapse", The Journal of hand surgery, 19, pp.751~759 (1994)
  4. A. W. Bach, "Proximal row fusion as a solution for radiocarpal arthritis", The Journal of hand surgery, 16, pp.424~431 (1991)
  5. J. Ishikawa, "The effects of wrist distraction on carpal kinematics", The Journal of hand surgery, 24, pp.113~120 (1999)
  6. H. Moritomo, "In vivo three-dimensional kinematics of the midcarpal joint of the wrist", The Journal of Bone & Joint Surgery, 88, pp.611~621 (2006)
  7. S. Yoshioka, "Changes in carpal tunnel shape during wrist joint motion MRI evaluation of normal volunteers", The Journal of Hand Surgery : British & European Volume, 18, pp.620~623 (1993)
  8. J. J. Crisco, "In vivo radiocarpal kinematics and the dart thrower's motion", The Journal of Bone & Joint Surgery, 87, pp.2729~2740 (2005)
  9. S. W. Wolfe, "The dart-throwing motion of the wrist : is it unique to humans?", The Journal of hand surgery, 31, pp.1429~1437 (2006)
  10. W. H. Short, "The effect of sectioning the dorsal radiocarpal ligament and insertion of a pressure sensor into the radiocarpal joint on scaphoid and lunate kinematics", The Journal of hand surgery, 27, pp.68~76 (2002)
  11. R. A. Berger, "The three-dimensional rotational behaviors of the carpal bones", Clinical Orthopaedics and Related Research, 167, pp.303~ (1982)
  12. R. A. Berger, "The anatomy of the ligaments of the wrist and distal radioulnar joints", Clinical orthopaedics and related research, 383, pp.32~40 (2001)
  13. S. K. Sarrafian, "Study of wrist motion in flexion and extension", Clinical orthopaedics and related research, pp.153~ (1977)
  14. R. A. Kaufmann, "Kinematics of the Midcarpal and Radiocarpal Joint in Flexion and Extension : An In Vitro Study", The Journal of hand surgery, 31, pp.1142~1148 (2006)
  15. A. J. Thurston, "Dowel Fusion of the Scapho-Trapezio-Trapezoid Joint : A Description of a New Technique", Hand Surg, 4, pp.125~129 (1999)
  16. R. Meier, "Scaphotrapezio-trapezoid arthrodesis(triscaphe arthrodesis)", Handchir Mikrochir Plast Chir, 35, pp.323~327 (2003)
  17. J. Bare, "Scaphotrapezial joint arthroscopy : a palmar portal", J Hand Surg Am, 28, pp.605~609 (2003)
  18. P. Voche, "Scapho-trapezio-trapezoid arthrodesis in the treatment of Kienbock's disease. A study of 16 cases", J Hand Surg Br, 17, pp.5~11 (1992)
  19. D. F. Massimini, "Non-invasive determination of coupled motion of the scapula and humerus-An in-vitro validation", Journal of Biomechanics, 44, pp.408~412 (2011)
  20. M. Kobayashi, "Normal kinematics of carpal bones : a three-dimensional analysis of carpal bone motion relative to the radius", Journal of biomechanics, 30, pp.787~793 (1997)
  21. H. Savelberg, "Human carpal ligament recruitment and threedimensional carpal motion", Journal of orthopaedic research, 9, pp.693~704 (1991)
  22. C. Neu, "In vivo kinematic behavior of the radio-capitate joint during wrist flexion–extension and radio-ulnar deviation", Journal of biomechanics, 34, pp.1429~1438 (2001)
  23. S. W. Wolfe, "In vivo scaphoid, lunate, and capitate kinematics in flexion and in extension", The Journal of hand surgery, 25, pp.860~869 (2000)
  24. J. J. Crisco, "Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics", Journal of orthopaedic research, 17, pp.96~100 (2005)
  25. T. Molet, "A real time anatomical converter for human motion capture" (1996), in EGCAS’96: Seventh International Workshop on Computer Animation and Simulation
  26. T. L. Grigorie, "The influences of the gyro sensors' errors on the attitude calculus", in ELMAR, 2007, pp.85~92 (2007)
  27. Z. M. Li, "Coupling between wrist flexion–extension and radial–ulnar deviation", Clinical Biomechanics, 20, pp.177~183 (2005)
  28. A. G. Kirk, "Skeletal parameter estimation from optical motion capture data", in Computer Vision and Pattern Recognition, 2005. CVPR 2005. IEEE Computer Society Conference on, pp.782~788 (2005)
  29. F. Wang, "Gait analysis and validation using voxel data", in Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE, pp.6127~6130 (2009)
  30. H. Je, "Hand gesture recognition to understand musical conducting action", in Robot and Human interactive Communication, 2007. RO-MAN 2007. The 16th IEEE International Symposium on, pp.163~168 (2007)
  31. H. Bade, "Arthrosis in the peritrapezial joints of the hand", Surg Radiol Anat, 18, pp.209~214 (1996)
  32. "Ann Chir Main Memb Super", 1991, 22~29
  33. H. Moritomo, "2007 IFSSH committee report of Wrist Biomechanics Committee : biomechanics of the socalled dart-throwing motion of the wrist", The Journal of hand surgery, 32, pp.1447~1453 (2007)
  34. H. Seradge, "The effect of intercarpal joint motion on wrist motion : are there key joints? An in vitro study", Orthopedics, 18, pp.727~732 (1995)
  35. S. V. Gehrmann, "Wrist circumduction reduced by finger constraints", The Journal of hand surgery, 33, pp.1287~1292 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (7건)