Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important sincethe abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoringsystem based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratorysignals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluatedusing a commercialized infant simulator (SimbabyTM) and a respiration belt transducer was used to measurerespiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between IandQ-channel and the respiration belt were 0.84 and 0.91 and the mean ± standard deviations of errors between themwere 1.66 ± 1.92 (bpm) and 0.88 ± 1.65 (bpm). Heart rates showed that the correlation coefficient between air mattressand set value of the simulator was 0.73 and the mean ± standard deviation of errors between them was1.09 ± 3.45 (bpm). These results indicate that the designed system holds the potential as an effective monitoring toolfor continuous monitoring heart rates and respiratory rates of newborns or infants.
Abstract
Continuous monitoring of heart rates and respiratory rates for newborns or infants is very important sincethe abnormal breathing and heart problems can threaten the life of newborns or infants. A noncontact baby monitoringsystem based on a Doppler radar and an air mattress was designed. The Doppler radar was used to acquire respiratorysignals and the air mattress was employed to obtain heart rates. The performance of the designed system was evaluatedusing a commercialized infant simulator (SimbabyTM) and a respiration belt transducer was used to measurerespiration rates as a reference. Results for respiratory rates revealed that the correlation coefficients between IandQ-channel and the respiration belt were 0.84 and 0.91 and the mean ± standard deviations of errors between themwere 1.66 ± 1.92 (bpm) and 0.88 ± 1.65 (bpm). Heart rates showed that the correlation coefficient between air mattressand set value of the simulator was 0.73 and the mean ± standard deviation of errors between them was1.09 ± 3.45 (bpm). These results indicate that the designed system holds the potential as an effective monitoring toolfor continuous monitoring heart rates and respiratory rates of newborns or infants.
참고문헌 (14)
- 서경, "한국인 신생아 사망의 사인 및 산과적 원인 분석", Obstetrics & Gynecology Science, 44(10), pp.1844~1850 (2001), 대한산부인과학회
- 김창렬, "신생아 집중치료실에 입원한 미숙아에서 패혈증에 대한 위험인자", Korean Journal of Pediatrics, 43(9), pp.1174~1179 (2000), 대한소아과학회
- S. H. Abman, "Monitoring cardiovascular function in infants with chronic lung disease of prematurity", Arch Dis Child Fetal Neonatal, Ed 87, pp.F15~F18 (2002)
- T. Matsuda., "ECG Monitoring of a car driver using capacitively-coupled electrodes", 30th Annual International IEEE EMBS Conference, Vancouver, Canada, pp.1315~1318 (2008)
- Y. G. Lim., "ECG Recording on a bed during sleep without direct skin-contact", IEEE Trans. Biomed. Eng, 54(4), pp.718~725 (2006)
- A. K. Abbas., "Neonatal non-contact respiratory monitoring based on real-time infrared thermography", BioMedical Engineering OnLine, 10(93) (2011)
- R. M. DiBlasi, "Neonatal noninvasive ventilation techniques : do we really need to intubate?", Respiratory Care, 56(9), pp.1273~1297 (2011)
- B. K. Park., "Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems", IEEE Trans. Microw. Theory Tech, 55(5), pp.1073~1079 (2007)
- 김완태, "MG-PSO 알고리즘을 적용한 PTS 기법에 의한OFDM 신호의 PAPR 감소", 전자공학회논문지 - TC, 46(1), pp.1~9 (2009), 대한전자공학회
- N. Hafner., "Fish heart rate monitoring by body-contact Doppler radar", IEEE Sens. J, 13(1), pp.408~414 (2013)
- A. Susan, "Normal vital signs in children : Heart rate, respirations, temperature, and blood pressure", Complex Child EMagazine, pp.1~4 (2008)
- S. K. Nagarkoti., "An algorithm for fetal heart rate detection using wavelet transform", 1st Int’l Conf. on Recent Advances in Information Technology, pp.838~840 (2012)
- C. M. Tenedero., "Design and implementation of a single-channel ECG amplifier with DSP post-processing in Matlab", Third National Electronics & Engineering Conference, pp.1~4 (2002)
- Y. Xiao., "A Kaband low power Doppler radar system for remote detection of cardiopulmonary motion", Proc. 27th IEEE Annu. Eng. Med. Biol. Soc. Conf., pp.7151~7154 (2005)