종이기반 농도 구배 형성 칩을 통한 포도당 발색 반응 검사
A Colorimetric Glucose Assay via Concentration Gradient Paper Chip
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This paper presents a paper-based concentration gradient chip to analyze colorimetric glucose assay. The paper-based concentration gradient chip was fabricated through a wax patterning technique that can design the fluidic channel by selectively printing hydrophobic and hydrophilic areas. Afterwards, glucose and dilution solutions were loaded into the inlet of a concentration gradient chip and each solution was then mixed sequentially at mixing channel. Finally, concentration gradient was formed at each outlet of the chip. To measure the glucose concentration of the solution in outlets, we conducted colorimetric glucose assay with fixed concentration of glucose solution (0, 5, 10, 15 and 20 mM) and obtained normalized intensity. Subsequently, glucose concentrations of the outlets were calculated by substituting the normalized intensity to linear regression function based on the normalized intensity of fixed glucose concentration. Finally, the concentration gradient of glucose was formed on the chip with the result of colorimetric assay. The concentration gradient paper chip has the potential to accurately analyze unknown glucose concentration.
Abstract
This paper presents a paper-based concentration gradient chip to analyze colorimetric glucose assay. The paper-based concentration gradient chip was fabricated through a wax patterning technique that can design the fluidic channel by selectively printing hydrophobic and hydrophilic areas. Afterwards, glucose and dilution solutions were loaded into the inlet of a concentration gradient chip and each solution was then mixed sequentially at mixing channel. Finally, concentration gradient was formed at each outlet of the chip. To measure the glucose concentration of the solution in outlets, we conducted colorimetric glucose assay with fixed concentration of glucose solution (0, 5, 10, 15 and 20 mM) and obtained normalized intensity. Subsequently, glucose concentrations of the outlets were calculated by substituting the normalized intensity to linear regression function based on the normalized intensity of fixed glucose concentration. Finally, the concentration gradient of glucose was formed on the chip with the result of colorimetric assay. The concentration gradient paper chip has the potential to accurately analyze unknown glucose concentration.
참고문헌 (15)
- A. Yetisen, "Paper-based microfluidic point-of-care diagnostic devices", Lab Chip, 13(12), pp.2210~ (2013)
- A. Martinez, "Diagnostics for the Developing World : Microfluidic Paper-Based Analytical Devices", Anal. Chem, 82(1), pp.3~10 (2010)
- A. Martinez, "Patterned Paper as a Platform for Inexpensive, Low-Volume, Portable Bioassays", Angew. Chem, 119(8), pp.1340~1342 (2007)
- A. Martinez, "Simple Telemedicine for Developing Regions : Camera Phones and Paper-Based Microfluidic Devices for Real-Time, Off-Site Diagnosis", Anal. Chem, 80(10), pp.3699~3707 (2008)
- A. Martinez, "Three-dimensional microfluidic devices fabricated in layered paper and tape", Proc. Natl. Acad. Sci. U.S.A, 105(50), pp.19606~19611 (2008)
- W. Dungchai, "Use of multiple colorimetric indicators for paper-based microfluidic devices", Anal. Chim. Acta, 674(2), pp.227~233 (2010)
- S. McCalla, "A Simple Method for Amplifying RNA Targets(SMART)", J Mol Diagn, 14(4), pp.328~335 (2012)
- X. Li, "Paper-Based Microfluidic Devices by Plasma Treatment", Anal. Chem, 80(23), pp.9131~9134 (2008)
- E. Fu, "Two-Dimensional Paper Network Format That Enables Simple Multistep Assays for Use in Low-Resource Settings in the Context of Malaria Antigen Detection", Anal. Chem, 84(10), pp.4574~4579 (2012)
- N. Pollock, "A Paper-Based Multiplexed Transaminase Test for Low-Cost, Point-of-Care Liver Function Testing", Sci. Transl. Med, 4(152), pp.152~129 (2012)
- D. Cate, "Recent Developments in Paper-Based Microfluidic Devices", Anal. Chem, 87(1), pp.19~41 (2014)
- E. Nery, "Sensing approaches on paper-based devices : a review", Anal Bioanal Chem, 405(24), pp.7573~7595 (2013)
- X. Yang, "Integrated separation of blood plasma from whole blood for microfluidic paper-based analytical devices", Lab Chip, 12(2), pp.274~280 (2012)
- E. Carrilho, "Understanding Wax Printing : A Simple Micropatterning Process for Paper-Based Microfluidics", Anal. Chem, 81(16), pp.7091~7095 (2009)
- N. Walji, "Influence of Geometry and Surrounding Conditions on Fluid Flow in Paper-Based Devices", Micromachines, 7(5), pp.73~ (2016)
