초록
In this paper, we fabricated a low-cost glucose sensor with a simpler structure and fabrication process than the existing glucose sensor. The currently used glucose sensor has a three-layer structure with upper, middle, and bottom plates; here, we fabricated a single-layerglucose sensor using only a printing and dispensing process. We successfully fabricated the glucose sensor using a simple methodinvolving the formation of an electrode and insulator layer through a 2- or 3-step printing process on plastic or paper film, followed bythe dispensing of glucose oxidase solution on the electrode. Cyclic voltammetry (CV) and cyclic amperometry (CA) measurements wereused to evaluate the characteristics of the fabricated single-layer glucose sensor. Also, its sensitivity was analyzed through glucose-controlledblood measurements. Hence, a low-cost single-layer glucose sensor was fabricated with evaluation of its characteristics demonstratingthat it has useful application in medicine.
Abstract
In this paper, we fabricated a low-cost glucose sensor with a simpler structure and fabrication process than the existing glucose sensor. The currently used glucose sensor has a three-layer structure with upper, middle, and bottom plates; here, we fabricated a single-layerglucose sensor using only a printing and dispensing process. We successfully fabricated the glucose sensor using a simple methodinvolving the formation of an electrode and insulator layer through a 2- or 3-step printing process on plastic or paper film, followed bythe dispensing of glucose oxidase solution on the electrode. Cyclic voltammetry (CV) and cyclic amperometry (CA) measurements wereused to evaluate the characteristics of the fabricated single-layer glucose sensor. Also, its sensitivity was analyzed through glucose-controlledblood measurements. Hence, a low-cost single-layer glucose sensor was fabricated with evaluation of its characteristics demonstratingthat it has useful application in medicine.
참고문헌 (8)
- L. C. Clark, "Electorde system for continuous monitoring in cardiovacular", Annals New York Academy of Sciences, 102, pp.29~45 (1962)
- Joseph Wang, "Electrochemical glucose biosensors", Chemical Reviews, 108(2), pp.814~825 (2008)
- J. R. Mor, "Assay of glucose using an electrochemical enzymatic sensor", Analytical Biochemistry, 79, pp.319~328 (1977)
- J. Anzai, "Enzyme sensors prepared by layer-by-layer deposition of enzyme on the platinum electrode through avidin-biotin interaction", Sensors and Actuators B-Chem., 52(1), pp.3~9 (1998)
- N. G. Patel, "Screen-printed biosensors using defferent alcohol oxidase", Sensors and Actuators B-Chem., 75(1), pp.101~110 (2001)
- 이영태, "Cu", Ni, 센서학회지, pp.2006, 15(5)[DOI]
- 김아영, "친환경 종이 혈당 바이오센서 개발", 센서학회지, 22(3), pp.202~206 (2013), 한국센서학회[DOI]