The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be 5.82 W/m3 at 200 Ω. The maximum current density was 47.53 A/m3 without power overshoot even under 1 Ω. The ohmic resistance (Rs) and the charge transfer resistance (Rct) of the oxidation electrode using stainless steel skein electrode, were 0.56 Ω and 0.02 Ω, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was 6.64 Ω. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as 50 Ω, 300 Ω, 5 kΩ. It has been shown that the ohm resistance (Rs) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.
Abstract
The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be 5.82 W/m3 at 200 Ω. The maximum current density was 47.53 A/m3 without power overshoot even under 1 Ω. The ohmic resistance (Rs) and the charge transfer resistance (Rct) of the oxidation electrode using stainless steel skein electrode, were 0.56 Ω and 0.02 Ω, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was 6.64 Ω. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as 50 Ω, 300 Ω, 5 kΩ. It has been shown that the ohm resistance (Rs) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.
참고문헌 (25)
- 장인섭, "Electrochemically Active Bacteria (EAB) and Mediator-Less Microbial Fuel Cells", Journal of Microbiology and Biotechnology, 16(2), pp.163~177 (2006), 한국미생물·생명공학회
- H. Liu, "Electricity generation using an aircathode single chamber microbial fuel cell in the presence and absence of a proton exchange membrane", Environ. Sci. Technol, 38, pp.4040~4046 (2004)
- J. K. Jang, "Construction and operation of a novel mediator-and membrane-less microbial fuel cell", Process Biochemistry, 39, pp.1007~1012 (2004)
- G. C. Gil, "Operational parameters affecting the performance of a mediator-less microbial fuel cell", Biosens. Bioelectron, 18(4), pp.327~334 (2003)
- Z. He, "Electricity generation from artificial wastewater using an upflow microbial fuel cell", Environ. Sci. Technol, 39, pp.5262~5267 (2005)
- B. H. Kim, "Novel BOD(biological oxygen demand)sensor using mediator-less microbial fuel cell", Biotechnology letters, 25, pp.541~545 (2003)
- 송영채, "미생물연료전지의 재료 : 전극 및 분리막, 집전체", 대한환경공학회지, 31(9), pp.693~704 (2009), 대한환경공학회
- P. Clauwaet, "Minimizing losses in bio-electrochemical system : the road to application", Appl. Microbiol. Biotechnol, 79, pp.901~913 (2008)
- Jayashree C, "Electricity Generation from Retting Wastewater Consisting of Recalcitrant Compounds Using Continuous Upflow Microbial Fuel Cell", Biotechnology and Bioprocess Engineering, 20(4), pp.753~759 (2015), 한국생물공학회
- W. -W. Li, "Towards sustainable wastewater treatment by using microbial fuel cells-centered technologies", Energy Environ. Sci, 7, pp.911~924 (2014)
- G. Zhang, "Long-term operation of manure-microbial fuel cell", Bioresour. Technol, 180, pp.365~369 (2015)
- 김태영, "Assessment of Organic Removal in Series- and Parallel-connected Microbial Fuel Cell Stacks", Biotechnology and Bioprocess Engineering, 22(6), pp.739~747 (2017), 한국생물공학회
- J. An, "Occurrence and implications of voltage reversal in stacted microbial fuel cells", Chemsuschem, 7, pp.1689~1695 (2014)
- S.-E. Oh, "Voltage reversal during microbial fuel cell stack operation", J. Power Sources, 167, pp.11~17 (2007)
- L. Zhuang, "Scalable microbial fuel cell(MFC)stack for continuous real wastewater treatment", Bioresour. Technol, 106, pp.82~88 (2012)
- J. An, "Significance of maximum current for voltage boosting of microbial fuel cells in series", J. Power Sources, 323, pp.23~28 (2016)
- B. Kim, "Assistance current effect for prevention of voltage reversal in stacked microbial fuel cell systems", Chemsuschem, 2, pp.755~760 (2015)
- C. Donovan, "Power management system for a 2. 5Wremote sensor powered by a sediment microbial fuel cell", J. Power Sources, 196, pp.1171~1177 (2011)
- J. Winfield, "The power of glove: Soft microbial fuel cell for low-power electronics", J. Power Sources, 249, pp.327~332 (2014)
- J. An, "Concurrent control of power overshoot and voltage reversal with series connection of parallel-connected microbial fuel cells", Energy Technol, 4, pp.729~736 (2016)
- V.J. Watson, "Analysis of polarization methods for elimination of power overshoot in microbial fuel cells", Electrochemistry Communications, 13, pp.54~56 (2011)
- Z. He, "Exploring the use of electrochemical impedance spectroscopy (EIS) in microbial fuel cell studies", Energy Environ. Sci, 2, pp.215~219 (2009)
- K. Watanabe, "Recent developments in microbial fuel cell technologies for sustainable bioenergy", J. Biosci. Bioeng, 106(6), pp.528~536 (2008)
- R. A. Rozendal, "Tovards practical implementation of bioelectrochemical wastewater treatment", Trends in Biotechnol, 26(8), pp.450~459 (2008)
- 박경원, "미생물연료전지(MFC)에서 전류차단법(current interrupt technique)을 이용한 활성화전압손실(activation loss)과 저항전압손실(Ohmic loss)의 측정", 대한환경공학회지, 32(4), pp.357~362 (2010), 대한환경공학회