인체의 위 조직 시료에서 자기공명영상장치를 이용한 확산계수 측정에 대한 기초 연구
Ex Vivo MR Diffusion Coefficient Measurement of Human Gastric Tissue
2
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
The aim of this study is to investigate the feasibility of ex vivo MR diffusion tensor imaging technique in order to observe the diffusion-contrast characteristics of human gastric tissues. On normal and pathologic gastric tissues, which have been fixed in a polycarbonate plastic tube filled with 10% formalin solution, laboratory made 3D diffusion tensor Turbo FLASH pulse sequence was used to obtain high resolution MR images with voxel size of 0.5x0.5x0.5mm3 using 64x32x32mm3 field of view in conjunction with an acquisition matrix of 128x64x64. Diffusion weighted- gradient pulses were employed with b values of 0 and 600s/mm2 in 6 orientations. The sequence was implemented on a clinical 3.0-T MRI scanner(Siemens, Erlangen, Germany) with a home-made quadrature-typed birdcage Tx/Rx rf coil for small specimen. Diffusion tensor values in each pixel were calculated using linear algebra and singular value decomposition(SVD) algorithm. Apparent diffusion coefficient(ADC) and fractional anisotropy(FA) map were also obtained from diffusion tensor data to compare pixel intensities between normal and abnormal gastric tissues. The processing software was developed by authors using Visual C++(Microsoft, WA, U.S.A.) and mathematical/ statistical library of GNUwin32(Free Software Foundation).This study shows that 3D diffusion tensor Turbo FLASH sequence is useful to resolve fine micro-structures of gastric tissue and both ADC and FA values in normal gastric tissue are higher than those in abnormal tissue. Authors expect that this study also represents another possibility of gastric carcinoma detection by visualizing diffusion characteristics of proton spins in the gastric tissues.
참고문헌 (21)
- "Clinical review of gastric cancer in Korea", 26(2), pp.8~70 (1988)
- "Epidemiologic features and perspective of stomach cancer in Korea", 26(2), pp.9~64 (1998)
- "Chemoprevention of gastric cancer", 9(1), pp.1~7 (2004)
- "In vitro MR imaging of the resected stomach with a 4.7-T superconducting magnet", 191, pp.129~134 (1994)
- "Extraserosal invasion in advanced gastric cancer evaluation with MR imaging", 192, pp.87~91 (1994)
- "MRI for staging of gastric carcinoma results of an experimental prospective study", 21, pp.66~72 (1997)
- "In-vitro and ex-vivo MR Spectroscopy of human gastric tissue in Proc. 28th Annual Meeting of Korea society of medical biological engineering", pp.650~652 (2003)
- "findings for the stomach tissue of patients", pp.1478~ (2003)
- "Mun"Ex vivo 1H MR spectroscopy: normal gastric and cancer tissue" J Korean Gastric Cancer Assoc", 3(3), pp.151~157 (2003)
- "for evaluation of human gastric carcinoma", 22, pp.861~70 (2004)
- "T2-relaxation time measurement of ex vivo stomach tissue using 1H MRS in Proc. 29th Annual Meeting of Korea society of medical biological engineering", pp.149~ (2003)
- "T2-relaxation time measurement of metabolite peak in gastric using ex vivo proton magnetic resonance spectroscopy imaging", pp.375~377
- "T2-relaxation time measurement of metabolite peak in gastric tissue using ex vivo proton magnetic resonance spectroscopic imaging", 13, pp.2494~ (2005)
- "T2-relaxation time measurement of ex vivo 1H MR metabolite peaks for evaluation of human stomach cancer", 27(2), pp.53~58 (2006)
- "United States of America" (1992), Mosby
- "In vivo fiber tractography using DT-MRI data", 44, pp.625~632 (2000)
- "Chabriat"Diffusion tensor imaging: concepts and application" J.Magn. Reson. Imaging,", 13, pp.534~546 (2001)
- "Ex vivo MR diffusion anisotropy measurement for the evaluation of gastric tissue fiber direction using 3D Turbo STEAM sequence", may, pp.2006~
- "Magnetic resonance imaging of lumen wall using quadrature-typed inside-out receiver coil", pp.886~ (2001)
- "Quadrature-typed RF coil for in vitro magnetic resonance imaging", spectroscopy in Proc. 28th annual meeting of Koera society of medical biological engineering, 2003, 100~
- "Quadrature-typed RF Coil for In vitro Magnetic Resonance Imaging", Spectroscopy in Proc. 28th Annual Meeting of Korea society of medical biological engineering, 2003, 100~