본문 바로가기
KERD
논문KCI 등재

슬관절 전치환술에서 후방 안정 임플란트의 오정렬이 경골 기둥에 미치는 영향

Influence of Malalignment on Tibial Post in Total Knee Replacement Using Posterior Stabilized Implant

0

조회

0

다운로드

0

인용

0

참고문헌

초록

Abstract

Recently, it has been reported that the posterior stabilized implant, which is clinically used for the total knee replacement (TKR), may have failure risk such as wear or fracture by the contact pressure and stress on the tibial post. The purpose of this study is to investigate the influence of the malalignment of the posterior stabilized implant on the tibial post by estimating the distributions of contact pressure and von-Mises stress on a tibial post and to analyze the failure risk of the tibial post. Finite element models of a knee joint and an implant were developed from 1mm slices of CT images and 3D CAD software, respectively. The contact pressure and the von-Mises stress applying on the implant were analyzed by the finite element analysis in the neutral alignment as well as the 8 malalignment cases (3 and 5 degrees of valgus and varus angulations, and 2 and 4 degrees of anterior and posterior tilts). Loading condition at the 40% of one whole gait cycle such as 2000N of compressive load, 25N of anterior-posterior load, and 6.5Nm of torque was applied to the TKR models. Both the maximum contact pressure and the maximum von-Mises stress were concentrated on the anterior-medial region of the tibial post regardless of the malalignment, and their magnitudes increased as the degree of the malalignment increased. From present result, it is shown that the malalignment of the implant can influence on the failure risk of the tibial post.

참고문헌 (22)

  1. H.D. Clarke, "Polyethylene post failure in posterior stabilized total knee arthroplasty", 19, pp.652~657 (2004)
  2. S. Matsuda, "Change in knee alignment after total knee arthroplasty", 14, pp.566~570 (1999)
  3. J. Halloran P, "Explicit finite element modeling of total knee replacement mechanics", 38, pp.323~331 (2005)
  4. Y.S. Chiu, "Fracture of the polyethylene tibial post in a NexGen posteriorstabilized knee prosthesis", 19, pp.1045~1049 (2004)
  5. G.H. van Lenthe, "Stress shielding after total knee replacement may cause bone resorption in the distal femur", 79-b, pp.117~122 (1997)
  6. J.J. Liau, "The effect of malalignment on stresses in polyethylene component of total knee prostheses - a finite element analysis", 17, pp.140~146 (2002)
  7. A. Perillo-Marcone, "“The importance of tibial alignment - finite element analysis of tibial malalignment", 15, pp.1020~1027 (2000)
  8. S.K.T. Puloski, "Tibial post wear in posterior stabilized total knee arthroplasty an unrecognized source of polyethylene debris", 83-a, pp.390~397 (2001)
  9. T. Villa, "Contact stresses and fatigue life in a knee prosthesis comparison between in vitro measurements computational simulations", 37, pp.45~53 (2004)
  10. M.J.K. Bankes, "The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement", 10, pp.55~60 (2003)
  11. F.W. Werner, "The effect of valgus", varus alignment on load distribution in total knee replacements, 2005., pp.38, 349~355
  12. J.J. Callaghan, "Tibial post impingement in posterior-stabilized total knee arthroplasty", 404, pp.83~88 (2002)
  13. R.C. Wasielewski, "Tibial insert undersurface as a contributing source of polyethylene wear debris", 345, pp.53~59 (1997)
  14. W. Mesfar, "Biomechanics of the knee joint in flexion under various quadriceps forces", pp.424~434 (2005)
  15. E. Pena, "A threedimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint", 39, pp.1686~1701 (2006)
  16. P. Mestha, "Fracture of the polyethylene tibial post in posterior stabilized", 15, pp.814~815 (2000)
  17. C.H. Huang, "Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty - a case report", 14, pp.375~379 (1999)
  18. D.L. Bartel, "Stresses in polyethylene components of contemporary total knee replacements", 317, pp.76~82 (1995)
  19. C.H. Huang, "Influence of post-cam design on stresses on posterior-stabilized tibial posts", 450, pp.150~156 (2006)
  20. G. Li, "A validated three- dimensional computational model of a human knee joint", 121, pp.657~662 (1999)
  21. C.S. Heim, "“Tibial plateau surface stress in TKA"
  22. W.L. Sauer, "Fatigue performance of ultra-high-molecular-weight polyethylene: effect of gamma radiation sterilization", 17, pp.1929~1935 (1996)

관련 논문AI추천

퇴행성 슬관절염 환자의 슬관절 전치환술 전후 삼차원 보행 분석구정회, 빈성일, 송우현, 유종윤, 임승수, 조우신대한재활의학회 · Annals of Rehabilitation Medicine2002 · 제26권 제5호The Effect of Tibial Posterior Slope on Contact Force and Ligaments Stresses in Posterior-Stabilized Total Knee Arthroplasty-Explicit Finite Element AnalysisHwa-Yong Lee, Kwan-Kyu Park, Kyoung-Tak Kang, Sung-Hwan Kim, Sung Jae Kim대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제2호10^o 이상의 술 전 경골 후방경사각을 가진 후방십자인대 대치형 슬관절 전치환술김순명, 김종헌대한슬관절학회 · Knee Surgery and Related Research2011 · 제23권 제1호In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients배지훈, Ali Hosseini, Guoan Li, Kyung-Wook Nha, Sang-Eun Park, Tsung Yuan Tsai, Young-Min Kwon대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제2호The Influence of Postoperative Tibiofemoral Alignment on the Clinical Results of Unicompartmental Knee ArthroplastyJung Soo Lee, Kyung Hwan Boo, Kyung Tae Kim, Song Lee, Tae Woo Kim대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제2호Evaluation of the flexion gap with a distal femoral trial component in posterior-stabilized total knee arthroplastyAdachi Nobuo, Goki Kamei, Hiroyuki Inoue, Koki yoshioka, Masakazu Ishikawa, Satoru Sakurai, Shigeki Ishibashi, Yu Mochizuki대한슬관절학회 · Knee Surgery and Related Research2022 · 제34권

이 간행물의 다른 논문 (20건)