본문 바로가기
KERD
논문KCI 등재

플라스틱 광섬유를 이용한 호흡센서의 개발

Development of a Respiration Sensor Using Plastic Optical Fiber

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the BIOPACR system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study

Abstract

In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the BIOPACR system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study

참고문헌 (22)

  1. E.-K. Kim, "Cancellation of MRI motion artifact in image plane", Proc. IEEE Instrumentation and Measurement Technology Conference, 통권 : 1, pp.329~334 (2002)
  2. 신옥영, "환아에서 마취 유도 후 발생한 무기폐", Korean Journal of Anesthesiology, 48(2), pp.194~197 (2005), 대한마취과학회
  3. C. Larsson, "Respiratory monitoring during MR imaging", Acta Radiol, 40, pp.33~36 (1999)
  4. 정동근, "인체에서 맥파전달시간을 이용한 호흡노력 모니터링", 의공학회지, 23(6), pp.485~489 (2002), 대한의용생체공학회
  5. M. Folke, "Critical review of non-invasive respiratory monitoring in medical care", Med. Biol. Eng. Comput, 41, pp.377~383 (2003)
  6. 한동균, "휠체어에서 호흡수와 심박수 측정 및 이벤트 전송", 의공학회지, 29(6), pp.443~450 (2008), 대한의용생체공학회
  7. A. M. Cyna, "Aura: A new respiratory monitor and apnoea alarm for spontaneously breathing patients", Br. J. Anaesth, 67, pp.341~345 (1991)
  8. 김경아, "기능성 일회용 호흡관의 소형화 연구", 센서학회지, 14(4), pp.250~257 (2005), 한국센서학회
  9. H. T. Lim, "A Study on the design of carbon dioxide measurement system using infrared sensor and PID temperature control", J. Kor. Sensors Soc, 8(3), pp.259~263 (1999)
  10. 이인광, "의복착용형 무선 호흡모니터 시스템", 센서학회지, 17(2), pp.133~142 (2008), 한국센서학회
  11. 김경아, "호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성", 센서학회지, 16(1), pp.24~32 (2007), 한국센서학회
  12. D. W. Kim, "Development of respiratory monitoring system by inductive plethysmography", J. Biomed. Eng. Res, 16(3), pp.353~358 (1995)
  13. S. Sade, "Fiberoptic infrared radiometer for real time in situ thermometry inside an MRI system", Magn. Reson. Imaging, 19, pp.287~290 (2001)
  14. R. D. Rempt, "A fiber optic sensor detection of cardiac magnetic field", Proc. Fiber Optic Sensors in Medical Diagnostics, 1886, pp.181~185 (1993)
  15. A. C.S. Brau, "Fiber-optic stethoscope: A cardiac monitoring and gating system for magnetic resonance microscopy", Magn. Reson. Med, 47, pp.314~321 (2002)
  16. S. K. Lemieux, "An infrared device for monitoring the respiration of small rodents during magnetic resonance imaging", J. Magn. Reson. Imaging, 6(3), pp.561~564 (1996)
  17. A. Babchenko, "A fiber optic sensor for the assessment of breathing effort", Proc. Medical and Fiber Optic Sensors and Delivery Systems, 2631, pp.64~71 (1995)
  18. C. Davis, "A new fibre sensor for respiratory monitoring", Austral. Phys. Eng. Sci. Med, 20, pp.214~219 (1997)
  19. Q. Chen, "Optical fiber sensors for breathing diagnostics", Proc. Optical Fibers and Sensors for Medical Applications II, 4616, pp.14~20 (2002)
  20. H. Segawa, "Sensitivity of fiber-optic carbon dioxide sensors utilizing indicator dye", Sens. Actuators B, 94, pp.276~281 (2003)
  21. 유욱재, "Chalcogenide 광섬유를 이용한 호흡측정 센서 개발을 위한 기초 연구", 센서학회지, 16(5), pp.331~336 (2007), 한국센서학회
  22. J. Mulrooney, "Monitoring of carbon dioxide exhaust emissions using a mid-infrared spectroscopy", J. Opt. A: Pure Appl. Opt, 9, pp.S87~S91 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (11건)