의복착용형 무선 호흡모니터 시스템
Wearable wireless respiratory monitoring system
2
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65 mm×105 mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. CO2 inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with 0 ~5% CO2 was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal CO2 concentration were simultaneously measured in steady state. CO2 inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal CO2 concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.
Abstract
Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65 mm×105 mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. CO2 inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with 0 ~5% CO2 was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal CO2 concentration were simultaneously measured in steady state. CO2 inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal CO2 concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.
참고문헌 (14)
- 강영숙, "호흡 기계, In: 생리학", pp.415~457 (2005), 라이프사이언스, 서울
- 김덕원, "인덕턴스 호흡감시 시스템 의 개발", 의공학회지, 16(3), pp.353~358 (1995)
- R. H. Warren, "Calibration of computer-assisted(Respicomp) respiratory inductive plethysmography in newborns", AM. REV. RESPIR. DIS, 131, pp.564~567 (1985)
- Ambulatory Monitoring Inc., "Respitrace systems, Instruction manual", ~ (2004)
- 김경아, "호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성", 센서학회지, 16(1), pp.24~32 (2007), 한국센서학회
- P. Bonato, "Wearable sensors", systems and their impact on biomedical engineering, 2003, pp.22(3), 18~20
- E. Jovanov, "A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation", J. of NeuroEngineering and Rehabilitation, 2, pp.6~ (2005)
- 강문상, "전자회로" (2005), 피어슨에듀케이션코리아, 서울
- J. V. Wait, "Introduction to operational amplifier theory and applications", pp.47~54 (1975), McGraw Hill, Colombus
- "///" (2007)[URL]
- "///" (2007)[URL]
- F. S. Grodins, "Control of Pulmunary Ventilation, In: Respiratory function of the lung and its control", pp.108~141 (1978), Macmillan Publishing Co., Inc., New York
- American Thoracic Soceity, "Standardization of spirometry", Am. J. Respir. Cirt. Care Med, 152, pp.1107~1136 (1995)
- 한국표준협회, "임상용 전자식 스파이로미터(KS P 1222), In: 한국산업규격" (1989), 공업진흥청