주파수 추적 방식에 의한 이식형 의료기기용 무선전력전달 장치 구현

Implementation of a Transcutaneous Power Transmission System for Implantable Medical Devices by Resonant Frequency Tracking Method

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Recently, many implantable medical devices have been developed and manufactured in many countries. In these devices, generally, energy is supplied by a transcutaneous method to avoid the skin penetration due to the power wires. As the most transcutaneous power transmission methods, the electromagnetic coupling between two coils and resonance at a specific frequency has been used widely. However, in case of a transcutaneous power transmitter with a fixed switching frequency to drive an electromagnetic coil, inefficient power transmission and thermal damage by the undesirable current variation may occur, because the electromagnetic coupling state between a primary coil and a secondary coil is very sensitive to skin thickness of each applied position and by person. In order to overcome these defects, a transcutaneous power transmitter of which operating frequency can be automatically tracked into the resonance frequency at each environment has been designed and implemented. Through the results of experiments for different coil surroundings, we have been demonstrated that the implemented transcutaneous power transmitter can track automatically into a varied resonance frequency according to arbitrary skin thickness change.

Abstract

Recently, many implantable medical devices have been developed and manufactured in many countries. In these devices, generally, energy is supplied by a transcutaneous method to avoid the skin penetration due to the power wires. As the most transcutaneous power transmission methods, the electromagnetic coupling between two coils and resonance at a specific frequency has been used widely. However, in case of a transcutaneous power transmitter with a fixed switching frequency to drive an electromagnetic coil, inefficient power transmission and thermal damage by the undesirable current variation may occur, because the electromagnetic coupling state between a primary coil and a secondary coil is very sensitive to skin thickness of each applied position and by person. In order to overcome these defects, a transcutaneous power transmitter of which operating frequency can be automatically tracked into the resonance frequency at each environment has been designed and implemented. Through the results of experiments for different coil surroundings, we have been demonstrated that the implemented transcutaneous power transmitter can track automatically into a varied resonance frequency according to arbitrary skin thickness change.

참고문헌 (13)

  1. W.Liu, "Retinal prosthesis", IEEE International Solid-State Circuits Conference, 1, pp.218~219 (2004)
  2. M.Takahashi, "Signal transmission system for high frequency magnetic telemetry for an artificial heart", IEEE Transactions on Magnetics, 37(4), pp.2921~2924 (2001)
  3. W.Mayr, "Basic design and construction of the Vienna FES implants:Existing solutions and prospects for new generations of implants", Medical Engineering Physics, 23, pp.53~60 (2001)
  4. H.H.Kim, "Hearing aids:A review of what’s new", Otolaryngology Head and Neck Surgery, 134, pp.1943~1050 (2006)
  5. W.C.Brown, "The history of wireless power transmission", Solar Energy, 56(1), pp.3~21 (1996)
  6. H.Matsuki, "Transcutaneous DC-DC converter for totally implantable artificial heart using synchronous rectifier", IEEE Transactions on Magnetics, 32(5), pp.5118~5120 (1996)
  7. G. Wang, "A closed loop transcutaneous power transfer system for implantable devices with enhanced stability", in Proceedings of the International Symposium on Circuits and Systems, 4, pp.17~20 (2004)
  8. G. Wang, "Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants", IEEE Transactions on Circuits and Systems, 52(10), pp.2109~2117 (2005)
  9. C.H. Lin, "The tracking of the optimal operating frequency in a class E backlight inverter using the PLL technique", IEICE Transactions on Electronics, E88-C(6), pp.1253~1262 (2005)
  10. Jin-Ho Cho, "Development of Fully-Implantable Middle Ear Hearing Device with Differential Floating Mass Transducer : Current Status", 의공학회지, 26(5), pp.309~317 (2005), 대한의용생체공학회
  11. I.Y. Park, "A transcutaneous recharging system with the function of bi-directional signal transmission for fully implantable middle ear hearing devices", IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences, E89-A(6), pp.1692~1694 (2006)
  12. C.M. Zierhofer, "Geometric approach for coupling enhancement of magnetically coupled coils", IEEE Transactions on Biomedical Engineering, 43(7), pp.708~714 (1996)
  13. S. Atluri, "Design of a wideband power- efficient inductive wireless link for implantable biomedical devices using multiple carriers", IEEE EMBS Conference on Neural Engineering, pp.533~537 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (10건)