본문 바로가기
KERD
논문KCI 등재

실시간 광단층 모니터링 안구 수술용 현미경 프로브 개발

Development of The Intraoperative Surgical Optical Coherence Tomography Probe

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Intraoperative surgical microscope is an essential surgical equipment. However, it has a restriction to classify the retina layers because of the contrast differences. To solve this problem, operators use surgical instrument such as an intraocular mirror. In this case, it has to amputate the patient's eye. In this study, we developed a probe the intraoperative surgical optical coherence tomography. We expect that the developed OCT probe can overcome the limit of OCT and be applied as a real-time surgical tool. In this paper, we demonstrate applicability of the probe through rabbit's experimentation.

Abstract

Intraoperative surgical microscope is an essential surgical equipment. However, it has a restriction to classify the retina layers because of the contrast differences. To solve this problem, operators use surgical instrument such as an intraocular mirror. In this case, it has to amputate the patient's eye. In this study, we developed a probe the intraoperative surgical optical coherence tomography. We expect that the developed OCT probe can overcome the limit of OCT and be applied as a real-time surgical tool. In this paper, we demonstrate applicability of the probe through rabbit's experimentation.

참고문헌 (19)

  1. D. Schultheiss, "History of the microscope and development of microsurgery: A revolution for reproductive tract surgery", Andrologia, 34(4), pp.234~224 (2002)
  2. B. Cassin, "Dictionary of eye terminology", pp.20~25 (1990), Triad publishing company
  3. Rodieck, R. W, "The vertebrate retina: Principles of structure and function", pp.51~56 (1973), W.H. Freeman
  4. 서원문, "펨토초 레이져를 이용한 데스메막박리 각막내피층판 이식술의 초기 임상성적", 대한안과학회지, 49(1), pp.40~47 (2008), 대한안과학회
  5. 신광훈, "유리체출혈의 원인으로서의 망막열공과 열공망막박리의 비교 분석", 대한안과학회지, 52(4), pp.448~453 (2011), 대한안과학회
  6. R. Rabinowitz, "Comparison between clinical and ultrasound findings in patients with vitreous hemorrhage", Eye, 18(3), pp.253~236 (2004)
  7. B.H. Kim, "Lightless cataract surgery using a near-infrared operating microscope", J Cataract. Refr. Surg, 32(10), pp.1683~1690 (2006)
  8. H. Ikagawa, "Chemical toxicity of indocyanine green damages retinal pigment epithelium", Invest. Ophth. Vis. Sci, 46(7), pp.2531~2539 (2005)
  9. G. Widmann, "Use of a surgical navigation system for CT-guided template production", Int. J. Oral. Max. Impl, 22(1), pp.72~78 (2007)
  10. N. Nassif, "In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve", Opt. Exp, 12(3), pp.367~376 (2004)
  11. D. Huang, "Optical coherence tomography", Science, 254(5035), pp.1178~1181 (1991)
  12. B.E. Bouma, "Handbook of optical coherence tomography" (2002), Marcel Dekker. Inc
  13. B. Povazay, "Impact of enhanced resolution, speed and penetration on three-dimensional retinal optical coherence tomography", Opt. Exp, 17(5), pp.4134~4150 (2009)
  14. Y. Nakamura, "High-speed three-dimensional human retinal imaging by line-field spectral domain optical coherence tomography", Opt. Exp., 15(12), pp.7103~7116 (2007)
  15. J.A. Izatt, "Micrometerscale resolution imaging of the anterior eye in vivo with optical coherence tomography", Arch. Ophth, 112(12), pp.1584~1589 (1994)
  16. C.A. Puliato, "Imaging of macular diseases by optical coherence tomography", Ophthalmology, 102(2), pp.217~229 (1995)
  17. G.J. Jaffe, "Optical coherence tomography to detect and manage retinal disease and glaucoma", Am. J. Ophthalmol, 137(1), pp.156~169 (2004)
  18. M. Jeon, "Real time dual displaying handheld scanner-based compact spectral domain optical coherence tomography", Thesis ; Kyoungpook national univ, 6, pp.72~79 (2011)
  19. Y.K. Tao, "Intraoperative spectral domain optical coherence tomography for vitreoretinal surgery", Opt. Lett, 35(20), pp.3315~3317 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (6건)