We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be 1024 × 2000 × 300 pixels which took 9 seconds for visualization.

Abstract

We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be 1024 × 2000 × 300 pixels which took 9 seconds for visualization.

참고문헌 (11)

  1. D. Huang, "Optical coherence tomography", Science, 254(5035), pp.1178~1181 (1991)
  2. B.E. Bouma, "Marcel Dekker" (2002), Marcel Dekker, Inc
  3. A.F. Fercher, "Optical coherence tomography-principles and applications", Rep. Prog. Phys, 66, pp.239~303 (2003)
  4. Y.K. Tao, "High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation", Opt. Lett, (32), pp.2918~2920 (2007)
  5. K. Zhang, "Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system", Opt. Express, 18(11), pp.11772~11178 (2010)
  6. B. Považay, "Wide-Field Optical Coherence Tomography of the Choroid In Vivo", IOVS, 50(4), pp.1856~1863 (2009)
  7. 조남현, "High Speed SD-OCT System Using GPU Accelerated Mode for in vivo Human Eye Imaging", Journal of the Optical Society of Korea, 17(1), pp.68~72 (2013), 한국광학회
  8. 전만식, "Frequency Swept Laser at 1300 nm Using a Wavelength Scanning Filter Based on a Rotating Slit Disk", Journal of the Optical Society of Korea, 13(3), pp.330~334 (2009), 한국광학회
  9. L. An, "High-resolution 1050 nm spectral domain retinal optical coherence tomography at 120 kHz A-scan rate with 6. 1 mm imaging depth", B. Opt. Express, 4(2), pp.245~259 (2013)
  10. "Spectral Domain Optical Coherence Tomography(SD-OCT)"[URL]
  11. RWS. Chen, "Speed and Resolution Improve in Newest OCT", Review of Opthalmology, 84(88), pp.84~88 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (8건)