본문 바로가기
KERD
논문KCI 등재

ABO 동종 응집소 역가 측정을 위한 시험관 및 미세원주응집법의 평가

Evaluation of ABO Antibody Titration Using Tube and Column Agglutination Techniques

1

조회

0

다운로드

6

인용

0

참고문헌

키워드

초록

Background: ABO antibody titration is useful for the evaluation of ABO-incompatible bone marrow or solid organ transplantations, yet the results quite vary between different test methods used. We compared the results of microcolumn agglutination and tube methods. Methods: Anti-A and anti-B isoagglutionin titers were determined in 63 healthy individuals (23 O, 20 A, and 20 B blood groups) using 4 different methods: immediate spin tube (tube), microcolumn agglutination without anti-human globulin (AHG) (CAT), tube with AHG (tube-AHG) and microcolumn agglutination with AHG (CAT-AHG). Results: The median (range) titers of anti-A and anti-B in group O individuals by tube, CAT, tube-AHG, and CAT-AHG methods were 64 (8-512), 64(8-512), 128 (8-2,048), and 128 (16-2,048); 64 (16-128), 128 (16-256), 128 (16-512), and 256 (16-512), respectively. The median (range) titers of anti-A in group B and anti-B in group A individuals by the four methods were 64 (16-128), 128 (8-128), 128 (8-256), and 256 (8-256); 64 (8-128), 64 (8-128), 32 (8-128), and 64 (8-256), respectively. The isoagglutinin titer measured by CAT-AHGmethod was the highest. The titers measured by CAT and CAT-AHG methods were 0-1 titer higher than those by tube and tube-AHG methods, respectively. Whatever method was used, the isoagglutinin titers were higher in women than in men. Conclusions: CAT-AHG was the most sensitive method among the four methods tested. Since AHG titer values are critical for the clinical management and CAT has less manual procedures than tube method, CAT-AHG method could be used for the standardization of ABO antibody titration in different institutions.

Abstract

Background: ABO antibody titration is useful for the evaluation of ABO-incompatible bone marrow or solid organ transplantations, yet the results quite vary between different test methods used. We compared the results of microcolumn agglutination and tube methods. Methods: Anti-A and anti-B isoagglutionin titers were determined in 63 healthy individuals (23 O, 20 A, and 20 B blood groups) using 4 different methods: immediate spin tube (tube), microcolumn agglutination without anti-human globulin (AHG) (CAT), tube with AHG (tube-AHG) and microcolumn agglutination with AHG (CAT-AHG). Results: The median (range) titers of anti-A and anti-B in group O individuals by tube, CAT, tube-AHG, and CAT-AHG methods were 64 (8-512), 64(8-512), 128 (8-2,048), and 128 (16-2,048); 64 (16-128), 128 (16-256), 128 (16-512), and 256 (16-512), respectively. The median (range) titers of anti-A in group B and anti-B in group A individuals by the four methods were 64 (16-128), 128 (8-128), 128 (8-256), and 256 (8-256); 64 (8-128), 64 (8-128), 32 (8-128), and 64 (8-256), respectively. The isoagglutinin titer measured by CAT-AHGmethod was the highest. The titers measured by CAT and CAT-AHG methods were 0-1 titer higher than those by tube and tube-AHG methods, respectively. Whatever method was used, the isoagglutinin titers were higher in women than in men. Conclusions: CAT-AHG was the most sensitive method among the four methods tested. Since AHG titer values are critical for the clinical management and CAT has less manual procedures than tube method, CAT-AHG method could be used for the standardization of ABO antibody titration in different institutions.

참고문헌 (16)

  1. Beadling WV, "Clinical diagnosis and management by laboratory methods", pp.623~660 (2007), Saunders Elseviver
  2. Han KS, "Transfusion medicine", pp.165~ (2006), Korea Medical Publisher
  3. Song TJ, "ABO blood type incompatible liver transplantation in a child", J Korean Surg Soc, 55, pp.604~608 (1998)
  4. Shimmura H, "Role of anti-A", B antibody titers in results of ABO-incompatible kidney transplantation, 2000, pp.70, 1331~1335
  5. Lee SH, "Isoagglutinin titer in major ABO incompatible bone marrow transplantation", Korean J Blood Transfus, 8, pp.355~364 (1997)
  6. Kobayashi T, "A series of surveys on assay for anti-A", B antibody by Japanese ABO-incompatible Transplantation Committee, 2006, pp.13, 136~140
  7. Kumlien G, "Comparing the tube and gel techniques for ABO antibody titration, as performed in three European centers", Transplantation, 84(s), pp.17~19 (2007)
  8. 강민구, "시험관법을 이용한 검사법에 따른 ABO 동종 응집소 역가 비교", 대한수혈학회지, 20(3), pp.227~234 (2009), 대한수혈학회
  9. Walker PS, "Identification of antibodies to red cell antigens, In Technical manual", pp.483~484 (2008), American Association of Blood Banks
  10. Kim JS, "Evaluation of ABO isoagglutinin titers in Korean adults", Korean J Blood Transfus, 8, pp.119~124 (1997)
  11. Shirey RS, "Streamlining ABO antibody titrations for monitoring ABO-incompatible kidney transplants", Transfusion, 50, pp.631~634 (2010)
  12. Tobian AA, "The critical role of plasmapheresis in ABO-incompatible renal transplantation", Transfusion, 48, pp.2453~2460 (2008)
  13. AuBuchon JP, "Reducing the variation in performance of antibody titrations", Vox Sang, 95, pp.57~65 (2008)
  14. Rosner ER, "The influence of dialysis in 2-mercaptoethanol reduction of erythrocyte antibodies", Transfusion, 14, pp.47~50 (1974)
  15. King KE, "Antibody, complement and accommodation in ABO-incompatible transplants", Curr Opin Immunol, 16, pp.545~549 (2004)
  16. Mollison PL, "Blood transfusion in clinical medicine", pp.148~203 (1993), Blackwell Scientific Publications

관련 논문AI추천

이 간행물의 다른 논문 (9건)