본문 바로가기
KERD
논문KCI 등재

측두엽 간질 수술환자에서 두개강 전극의 발작기 뇌파와 수술예후 및 유용성

Intracranial Ictal EEG Patterns Predicting the Surgical Outcome and the Yield of Intracranial Electrodes in Patients with Temporal Lobectomy

1

조회

0

다운로드

0

인용

0

참고문헌

주제분류신경과학

초록

Abstract

Background: Analysis of intracranial ictal patterns may help to predict surgical outcomes. We investigated intracranial EEG patterns to correlate with surgical outcomes and compared the yield of ‘subdural electrodes alone (SE)’ versus ‘combined depth and subdural electrodes (CDSE)’ for ictal lateralization in temporal lobe epilepsy (TLE). Methods: We reviewed a total of 95 seizures recorded by bilateral temporal depth and subdural electrodes in 25 TLE patients who underwent surgery. We classified surgical outcomes as ‘seizure-free’ or ‘not-seizure-free’. Each seizure was analyzed based on the presence or absence of peri-ictal discharges, ictal distribution, waveform patterns, onset frequency and involved number of electrodes, and interhemispheric propagation time (IHPT). The accuracy of lateralizing seizure foci by CDSE was compared to that by SE. Results: 20 patients (80.0%) were ‘seizure-free’ and 5 (20.0%) were ‘not-seizure-free’. The presence of peri-ictal discharges (p<0.001), distribution of depth only or depth and medial electrodes (p<0.001) and higher onset frequency (p=0.021) were associated with ‘seizure-free’ outcomes. Ictal onset pattern with fast spike trains was common in ‘seizure-free’, whereas pattern with rhythmic activity was common in ‘not-seizure-free’ (p=0.005). SE correctly lateralized in 18 of 20 patients, and incorrectly lateralized in the remaining 2 patients, but CDSE correctly lateralized in all 20 patients. Conclusions: Some intracranial ictal patterns were significantly correlated with good surgical outcomes. These findings suggest that the analysis of ictal EEG patterns help to predict surgical outcomes. CDSE is more accurate for the lateralization of seizure foci compared to SE.

참고문헌 (25)

  1. "Temporal lobectomy for refractory epilepsy", 276, pp.470~475 (1996)
  2. "Surgery for seizures", 334, pp.647~652 (1996)
  3. "Clinical challenges in invasive monitoring in epilepsy surgery", 38, pp.6~12 (1997)
  4. "Electro-clinical characteristics and postoperative outcome of medically refractory tumoral temporal lobe epilepsy", 53, pp.66~71 (2005)
  5. "Combined bilateral depth and subdural electrode investigation in temporal lobe epilepsy", 18, pp.589~594 (2000)
  6. "Spencer D. Morphological patterns of seizures recorded intracranially. Epilepsia 1992", pp.537~545
  7. "Ictal spiking patterns recorded from temporal depth electrodes predict good outcome after anterior temporal lobectomy", 41, pp.316~319 (2000)
  8. "Chronic intracranial EEG monitoring for localizing the epileptogenic zone: an electroclinical correlation", 39, pp.1302~1308 (1998)
  9. "O'Connor MJ. Comparison of depth and subdural electrodes in recording temporal lobe seizures. Neurology 1989", pp.1497~1504
  10. "Mattson R. Combined depth and subdural electrode investigation in uncontrolled epilepsy. Neurology 1990", pp.74~79
  11. "Ojemann LM. Outcome with respect to epileptic seizures. In Engel J Jr. Surgical treatment of the epilepsies. New York", pp.609~621 (1993), Raven Press
  12. "a marker of specific hippocampal cell loss. Electroencephalogr Clin Neurophysiol 1992", pp.104~111
  13. "Intracranial EEG in temporal lobe epilepsy", 16, pp.399~407 (1999)
  14. "Engel J Jr. Clinicopathological correlations of low voltage fast and high amplitude spike and wave mesial temporal stereoencephalographic ictal onsets. Epilepsia 1991", pp.21~
  15. "Invasive electroencephalography in mesial temporal lobe epilepsy", 12, pp.32~45 (1995)
  16. "Spencer DD. Entorhinal-hippocampal interactions in medial temporal lobe epilepsy. Epilepsia 1994", pp.721~727
  17. "Neocortical temporal lobe epilepsy: intracranial EEG features and surgical outcome", 16, pp.419~425 (1999)
  18. "Intracranial EEG substrates of scalp ictal patterns from temporal lobe foci", 38, pp.642~654 (1997)
  19. "Babb TL. Interhemispheric propagation time of human hippocampal seizures I. Relationship to surgical outcome. Epilepsia 1986", pp.286~293
  20. "Babb TL. Interhemispheric propagation time of human hippocampal seizures II. Relationship to pathology and cell density. Epilepsia 1986", pp.294~300
  21. "Subdural strip elcetrode studies in temporal lobe epilepsy: Relation between interhemispheeric propagation time and surgical outcome", 20, pp.497~503 (2002)
  22. "Ictal patterns of neocortical seizures monitored with intracranial electrodes: correlation with surgical outcome", 40, pp.257~266 (1999)
  23. "Intracranial depth electrode monitoring in partial epilepsy: the morbidityand efficacy of placement using magnetic resonance image-guided stereotactic surgery", 39, pp.327~333 (1996)
  24. "Volans A. Utility of stereoelectroencephalography in preoperative assessment of temporal lobe epilepsy. J Neurol Neurosurg Psychiatry 1994", pp.58~65
  25. "Comparison of Combined Versus Subdural or Intracerebral Electrodes Alone in Presurgical Focus Localization", 39, pp.1290~1301 (1998)

관련 논문AI추천

이 간행물의 다른 논문 (17건)