초록

Abstract

Background: The purpose of this study was to localize the cortical regions reflected by overlying scalp electrodes. Methods: We enrolled 10 patients with epilepsy (5 males, mean age 29.7 years old). Thin slice coronal T1 weighted MR images were obtained and then scalp EEG electrodes were placed based on an international 10-20 system. Cortical locations of scalp electrodes were determined using a real-time frameless stereotactic image guidance system, Brainsight. Results: The locations of 19 scalp electrodes were marked on the 3D rendered cortical surface of one representative patient’s MRI; Fp1 (Fp2) on the anterior pole of the middle frontal gyrus, Fz on the mid-point of the interhemispheric fissure in the frontal lobe, F3 (F4) on the mid-portion of the middle frontal gyrus, F7 (F8) on the pars triangularis of the inferior frontal gyrus, Cz on the interhemispheric fissure where a lateral precentral gyrus starts, C3 (C4) scattered around postcentral gyrus, T3 (T4) on the middle temporal gyrus, P3 (P4) on the angular gyrus, Pz on the mid-point of the interhemispheric fissure in the parietal lobe, T5 (T6) on the posterior part of the inferior temporal gyrus, and O1 (O2) on the occipital pole. Conclusions: The locations of scalp electrodes were well correlated with conventional concepts of their cortical locations. The individual differences of the scalp electrode locations may be due to the different sizes and morphologies of the brains in each of the patients. Real time cortical localization of scalp electrodes using the Frameless Stereotactic Image Guidance System may provide useful information for more accurate localization of focal cerebral activity in partial epilepsy patients.

참고문헌 (13)

  1. "EEG source imaging", 115, pp.2195~2222 (2004)
  2. "Okazaki H. Anatomic correlates of the ten- twenty electrode placement system in infants. Electroencephalogr Clin Neurophysiol 1974", pp.303~307
  3. "Mussbichler H. Electrode placement in EEG of infants and its anatomical relationship studied radiographically. Electroencephalogr Clin Neurophysiol 1963", pp.115~117
  4. "Purdy P. Cerebral location of international 10-20 system electrode placement. Electroencephalogr Clin Neurophysiol 1987", pp.376~382
  5. "Automatic localization of EEG electrode markers within 3D MR data", 18, pp.485~488 (2000)
  6. "3D Localization of surface 10-20 EEG electrodes on high resolution anatomical MR images", 102, pp.335~339 (1996)
  7. "Morris H. Registration of EEG Electrodes with Three-Dimensional Neuroimaging Using a Frameless", pp.32~38
  8. "Robb RA. Scalp-recorded EEG localization in MRI volume data. Brain Topogr 1988", pp.245~253
  9. "et al. The spatial location of EEG electrodes locating the best- fitting sphere relative to cortical anatomy. Electroencephalogr Clin Neurophysiol 1993", pp.1~6
  10. "Weinberger DR. Adequacy of the international 10-20 electrode system for computed neurophysiologic topography. J Clin Neurophysiol 1990", pp.507~518
  11. "left-right asymmetries in temporal speech region. Science 1968"
  12. "Salamon G. CT assessment of right-left asymmetries in the human cerebral cortex. J Comput Assist Tomogr 1984", pp.922~927
  13. "Hutton TJ. Asymmetry of the lateral fissures in man. Neurology 1976", pp.620~624

관련 논문AI추천

이 간행물의 다른 논문 (15건)