Skin Hydration Measurement: Comparison Between Devices and Clinical Evaluations

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류피부과학

초록

Background: The need for an objective method for measuring skin hydration levels is becoming increasingly important. Various devices with different measuring principles for assessing skin hydration have been developed and are widely used. Objective: This study aimed to investigate the reproducibility and correlation between clinical evaluation and skin hydration measurement devices that are the most widely used in the field. Methods: A prospective comparative clinical trial was conducted on 184 healthy volunteers. Skin hydration levels were measured using the Corneometer (CM820) and hydration probe (HP: Der- maLab Combo) at 3 points: the ventral forearm, the dorsal forearm, and the shin. We used the intraclass correlation coefficient (ICC) to evaluate the reproducibility and Pearson’s correlation coefficient (PCC) to evaluate the correlation of each measurement. Simple linear regression was used to analyze the Corneometer and HP skin hydration value changes according to changes in xerosis severity scale (XSS) values, which were evaluated by clinicians. Results: Both the Corneometer and HP showed significant, excellent reproducibility (ICC for Corneometer: 0.954–0.971, ICC for HP: 0.980–0.986) and significant high positive correlations (PCC: 0.708–0.737) regardless of the measurement site. Both devices showed negative regression coefficients in all measurement sites in XSS analysis, but this was not statistically significant. Conclusion: The Corneometer and HP were both accurate and objective skin hydration mea- suring devices, regardless of the measurement site. Using reliable and objective devices such as the Corneometer or HP can aid in understanding an individual’s skin condition and making more informed decisions for skin care.

Abstract

Background: The need for an objective method for measuring skin hydration levels is becoming increasingly important. Various devices with different measuring principles for assessing skin hydration have been developed and are widely used. Objective: This study aimed to investigate the reproducibility and correlation between clinical evaluation and skin hydration measurement devices that are the most widely used in the field. Methods: A prospective comparative clinical trial was conducted on 184 healthy volunteers. Skin hydration levels were measured using the Corneometer (CM820) and hydration probe (HP: Der- maLab Combo) at 3 points: the ventral forearm, the dorsal forearm, and the shin. We used the intraclass correlation coefficient (ICC) to evaluate the reproducibility and Pearson’s correlation coefficient (PCC) to evaluate the correlation of each measurement. Simple linear regression was used to analyze the Corneometer and HP skin hydration value changes according to changes in xerosis severity scale (XSS) values, which were evaluated by clinicians. Results: Both the Corneometer and HP showed significant, excellent reproducibility (ICC for Corneometer: 0.954–0.971, ICC for HP: 0.980–0.986) and significant high positive correlations (PCC: 0.708–0.737) regardless of the measurement site. Both devices showed negative regression coefficients in all measurement sites in XSS analysis, but this was not statistically significant. Conclusion: The Corneometer and HP were both accurate and objective skin hydration mea- suring devices, regardless of the measurement site. Using reliable and objective devices such as the Corneometer or HP can aid in understanding an individual’s skin condition and making more informed decisions for skin care.

참고문헌 (22)

  1. Verdier-Sévrain S, "Skin hydration : a review on its molecular mechanisms", J Cosmet Dermatol, 6, pp.75~82 (2007)
  2. Wilhelm KP, "Skin aging. Effect on transepidermal water loss, stratum corneum hydration, skin surface pH, and casual sebum content", Arch Dermatol, 127, pp.1806~1809 (1991)
  3. Rogers RS 3rd, "Comparative efficacy of 12% ammonium lactate lotion and 5% lactic acid lotion in the treatment of moderate to severe xerosis", J Am Acad Dermatol, 21, pp.714~716 (1989)
  4. Morin M, "Skin hydration dynamics investigated by electrical impedance techniques in vivo and in vitro", Sci Rep, 10, pp.17218~ (2020)
  5. Tagami H, "Electrical measurement of the hydration state of the skin surface in vivo", Br J Dermatol, 171(Suppl 3), pp.29~33 (2014)
  6. Van Neste D, "Comparative study of normal and rough human skin hydration in vivo : evaluation with four different instruments", J Dermatol Sci, 2, pp.119~124 (1991)
  7. Hadi H, "The investigation of the skin biophysical measurements focusing on daily activities, skin care habits, and gender differences", Skin Res Technol, 22, pp.247~254 (2016)
  8. Clarys P, "Hydration measurements of the stratum corneum : comparison between the capacitance method(digital version of the Corneometer CM 825®)and the impedance method(Skicon-200EX®)", Skin Res Technol, 18, pp.316~323 (2012)
  9. Heinrich U, "Multicentre comparison of skin hydration in terms of physical-, physiological-and product-dependent parameters by the capacitive method(Corneometer CM 825)", Int J Cosmet Sci, 25, pp.45~53 (2003)
  10. Fluhr JW, "Comparative study of five instruments measuring stratum corneum hydration(Corneometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part II. In vivo", Skin Res Technol, 5, pp.171~178 (1999)
  11. Hashmi F, "The reliability of non-invasive biophysical outcome measures for evaluating normal and hyperkeratotic foot skin", J Foot Ankle Res, 8, pp.28~ (2015)
  12. Choi Y, "Novel technology at hand to measure skin hydration by Biodisplay smartphone touch screen panel", Sci Rep, 11, pp.19410~ (2021)
  13. "R: a language and environment for statistical computing" (2013)[URL]
  14. Koo TK, "A guideline of selecting and reporting intraclass correlation coefficients for reliability research", J Chiropr Med, 15, pp.155~163 (2016)
  15. Lipsitz SR, "A partial correlation coefficient and coefficient of determination for multivariate normal repeated measures data", Statistician, 50, pp.87~95 (2001)
  16. Hinkle DE, "Applied statistics for the behavioral sciences" (2003), Houghton Mifflin College Division
  17. Sator PG, "Comparison of epidermal hydration and skin surface lipids in healthy individuals and in patients with atopic dermatitis", J Am Acad Dermatol, 48, pp.352~358 (2003)
  18. Shim JH, "Moisturizers are effective in the treatment of xerosis irrespectively from their particular formulation : results from a prospective, randomized, double-blind controlled trial", J Eur Acad Dermatol Venereol, 30, pp.276~281 (2016)
  19. Alanen E, "Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the Corneometer", Skin Res Technol, 10, pp.32~37 (2004)
  20. Westermann TV, "Measurement of skin hydration with a portable device(SkinUp® Beauty Device)and comparison with the Corneometer®", Skin Res Technol, 26, pp.571~576 (2020)
  21. Hua W, "Comparison of two series of non-invasive instruments used for the skin physiological properties measurements : the DermaLab® from Cortex Technology vs. the series of detectors from Courage & Khazaka", Skin Res Technol, 23, pp.70~78 (2017)
  22. Berardesca E, "The revised EEMCO guidance for the in vivo measurement of water in the skin", Skin Res Technol, 24, pp.351~358 (2018)

이 간행물의 다른 논문 (9건)