A Comparison of Humidified High Flow Nasal Cannula with Bubble CPAP in Very Low Birth Weight Infants

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: To compare the effect of humidified high flow nasal cannula (HHFNC) with that of nasal continuous positive airway pressure (NCPAP) as the mode of extubation in very low birth weight infants (VLBWI). Methods: Medical records were retrospectively reviewed for 219 VLBWI who were admitted to the neonatal intensive care unit of Ajou University Hospital from January 2009 through December 2012; 87 were supported by noninvasive ventilation (NIV) after extubation (HHFNC n=47, NCPAP n=40). Extubation failure was defined as the need for reintubation within 1 week of extubation. Results: (1) There were no significant differences between the groups in demographic data such as gestational age, birth weight, and age at extubation. (2) There were no significant differences in fraction of inspired oxygen (FiO2) (HHFNC 0.23±0.03 vs. NCPAP 0.23±0.03, P-value .937) and peak inspiratory pressure (HHFNC 11±6.6 cmH2O vs. NCPAP 10.3±3.4 cmH2O, P-value .559) before extubation. (3) The rate of extubation failure and FiO2 values after extubation were similar in the 2 groups (extubation failure, HHFNC 5/47 vs. NCPAP 5/40, P-value 1.000; FiO2, HHFNC 0.24±0.05 vs. NCPAP 0.25±0.04, P-value .399). (4) Among patients who received NIV after extubation once but did not receive further intubation, the duration of NIV or duration of oxygen supply were not significantly different between the groups (NIV, HHFNC 12.4±9.1 days vs. NCPAP 8.7±12.3 days, P-value .159, oxygen supply, HHFNC 49.0±40.3 days vs. NCPAP 50.9±41.3 days, P-value .844) or bronchopulmonary dysplasia rate (HHFNC 24.3% vs. NCPAP 34.4%, P-value .430). Conclusion: HHFNC is as effective as NCPAP for weaning VLBWIs from invasive mechanical ventilation.

Abstract

Purpose: To compare the effect of humidified high flow nasal cannula (HHFNC) with that of nasal continuous positive airway pressure (NCPAP) as the mode of extubation in very low birth weight infants (VLBWI). Methods: Medical records were retrospectively reviewed for 219 VLBWI who were admitted to the neonatal intensive care unit of Ajou University Hospital from January 2009 through December 2012; 87 were supported by noninvasive ventilation (NIV) after extubation (HHFNC n=47, NCPAP n=40). Extubation failure was defined as the need for reintubation within 1 week of extubation. Results: (1) There were no significant differences between the groups in demographic data such as gestational age, birth weight, and age at extubation. (2) There were no significant differences in fraction of inspired oxygen (FiO2) (HHFNC 0.23±0.03 vs. NCPAP 0.23±0.03, P-value .937) and peak inspiratory pressure (HHFNC 11±6.6 cmH2O vs. NCPAP 10.3±3.4 cmH2O, P-value .559) before extubation. (3) The rate of extubation failure and FiO2 values after extubation were similar in the 2 groups (extubation failure, HHFNC 5/47 vs. NCPAP 5/40, P-value 1.000; FiO2, HHFNC 0.24±0.05 vs. NCPAP 0.25±0.04, P-value .399). (4) Among patients who received NIV after extubation once but did not receive further intubation, the duration of NIV or duration of oxygen supply were not significantly different between the groups (NIV, HHFNC 12.4±9.1 days vs. NCPAP 8.7±12.3 days, P-value .159, oxygen supply, HHFNC 49.0±40.3 days vs. NCPAP 50.9±41.3 days, P-value .844) or bronchopulmonary dysplasia rate (HHFNC 24.3% vs. NCPAP 34.4%, P-value .430). Conclusion: HHFNC is as effective as NCPAP for weaning VLBWIs from invasive mechanical ventilation.

참고문헌 (18)

  1. De Paoli AG, "Nasal CPAP for neonates: what do we know in 2003?", Arch Dis Child Fetal Neonatal Ed, 88, pp.F168~F172 (2003)
  2. Hudson LD, "Progress in understanding ventilator-induced lung injury", JAMA, 282, pp.77~78 (1999)
  3. Jobe AH, "Mechanisms initiating lung injury in the preterm", Early Hum Dev, 53, pp.81~94 (1998)
  4. Andrade FH, "Noninvasive ventilation in neonates: the lungs don’t like it!", J Appl Physiol(1985), 105, pp.1385~1386 (2008)
  5. de Klerk A, "Humidified high-flow nasal cannula: is it the new and improved CPAP?", Adv Neonatal Care, 8, pp.98~106 (2008)
  6. Robertson NJ, "Nasal deformities resulting from flow driver continuous positive airway pressure", Arch Dis Child Fetal Neonatal Ed, 75, pp.F209~F212 (1996)
  7. Sreenan C, "High-flow nasal cannulae in the management of apnea of prematurity: a comparison with conventional nasal continuous positive airway pressure", Pediatrics, 107, pp.1081~1083 (2001)
  8. Locke RG, "Inadvertent administration of positive end-distending pressure during nasal cannula flow", Pediatrics, 91, pp.135~138 (1993)
  9. Frey B, "Nasopharyngeal oxygen therapy produces positive end-expiratory pressure in infants", Eur J Pediatr, 160, pp.556~560 (2001)
  10. Saslow JG, "Work of breathing using high-flow nasal cannula in preterm infants", J Perinatol, 26, pp.476~480 (2006)
  11. Waugh JB, "An evaluation of 2 new devices for nasal high-flow gas therapy", Respir Care, 49, pp.902~906 (2004)
  12. Jobe AH, "Bronchopulmonary dysplasia", Am J Respir Crit Care Med, 163, pp.1723~1729 (2001)
  13. Kamitsuka MD, "The incidence of necrotizing enterocolitis after introducing standardized feeding schedules for infants between 1250 and 2500 grams and less than 35 weeks of gestation", Pediatrics, 105, pp.379~384 (2000)
  14. Papile LA, "Incidence and evolution of subependymal and intraventricular hemorrhage: a study of infants with birth weights less than 1500 gm", J Pediatr, 92, pp.529~534 (1978)
  15. Shoemaker MT, "High flow nasal cannula versus nasal CPAP for neonatal respiratory disease: a retrospective study", J Perinatol, 27, pp.85~91 (2007)
  16. Holleman-Duray D, "Heated humidified high-flow nasal cannula: use and a neonatal early extubation protocol", J Perinatol, 27, pp.776~781 (2007)
  17. Campbell DM, "Nasal continuous positive airway pressure from high flow cannula versus Infant Flow for Preterm infants", J Perinatol, 26, pp.546~549 (2006)
  18. 윤성호, "미숙아에서 경비지속기도양압과 가습고유량비강캐뉼라의 사용에 대한 비교 연구", Neonatal medicine, 18(2), pp.293~300 (2011), 대한신생아학회

관련 논문AI추천

미숙아에서 경비지속기도양압과 가습고유량비강캐뉼라의 사용에 대한 비교 연구권영희, 김창렬, 박현경, 설인준, 윤성호, 이현주대한신생아학회 · Neonatal medicine2011 · 제18권 제2호Pulmonary Outcomes of Early Extubation in Extremely Premature Infants (Gestational Age: 25–26 Weeks) with Synchronized Nasal Intermittent Positive-Pressure Ventilation김천수, 박재현, 이상락, 최은미대한신생아학회 · Neonatal medicine2016 · 제23권 제2호인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향김정숙, 이은정한국아동간호학회 · Child Health Nursing Research2011 · 제17권 제2호Comparison of Effectiveness of Nasal Continuous Positive Airway Pressure and Nasal Intermittent Positive Pressure Ventilation for the Initial Treatment of Preterm Respiratory Distress Syndrome: A Prospective Pilot Study민세라, 이현수대한신생아학회 · Neonatal medicine2014 · 제21권 제3호Factors Associated with Nasal Intermittent Positive Pressure Ventilation Failure in Late Preterm and Term Infants with Respiratory Distress after Birth심규홍대한신생아학회 · Neonatal medicine2022 · 제29권 제1호High-flow nasal cannula therapy for children with complex chronic disease in the general ward: A single, tertiary center experience김민정, 김지혜, 박지수, 서동인, 이보라, 최윤정대한 소아알레르기 호흡기학회 · Allergy Asthma & Respiratory Disease2023 · 제11권 제1호

이 간행물의 다른 논문 (10건)