Manganese causes the black water of tap water. In this study, we investigated the effect of electrolysis for the removal of manganese under various conditions of electrode type, contact time, operating voltage, and catalyst use. The following results were obtained. The manganese removal rate is proportional to the contact time. The difference of manganese removal rate between the titanium electrode and the manganese dioxide coated electrode was not significant. The manganese removal rate was increased as the voltage increase up to 24V. However, it was slightly decreased at 30V. Manganese removal was not increased by electrolysis combined by aeration but the rate was rapidly increased by electrolysis combined with hydrogen peroxide.
Abstract
Manganese causes the black water of tap water. In this study, we investigated the effect of electrolysis for the removal of manganese under various conditions of electrode type, contact time, operating voltage, and catalyst use. The following results were obtained. The manganese removal rate is proportional to the contact time. The difference of manganese removal rate between the titanium electrode and the manganese dioxide coated electrode was not significant. The manganese removal rate was increased as the voltage increase up to 24V. However, it was slightly decreased at 30V. Manganese removal was not increased by electrolysis combined by aeration but the rate was rapidly increased by electrolysis combined with hydrogen peroxide.
참고문헌 (6)
- Seo H. Y., "An Experimental Study on the Removal of Manganese in the Raw Water by Electrolysis", Master, pp.2018
- 김충환, "망간모래여과를 이용한 강변여과수의 망간제거", 한국물환경학회지, 20(5), pp.409~414 (2004), 한국물환경학회
- 김진근, "산화망간피복여재를 이용한 용존망간 제거", 상하수도학회지, 20(6), pp.813~822 (2006), 대한상하수도학회
- Kohl P. M., "Occurrence of Manganese in Drinking Water and Manganese Control", AWWARF, EPA, 11~12 (2006)
- Patil D. S., , J. Env. Chem. Eng., 4, pp.468~487 (2016)
- Technical Report for the Optimal Manganese Removal Technology, "K-water Water and Wastewater Institute", K-water, 4~ (2012)