도립 현미경에 장착된 2축 스테이지 정밀도 특성에 관한 연구
A Study on Precision Characteristic of 2-Axis Stage mounted on a Inverted Microscope
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this paper, we propose a method to solve the problems that it is difficult to repeat the characteristics evaluation because it takes a lot of time to obtain the results of experiment or characterization analysis due to passive transfer in biological inverted microscope. It is possible to confirm the entire area of t h e well plate, which is a cell culture container, in a commercialized biological inverted microscope. In order to check the result of the property of the material or cell more quickly and conveniently than the driving time of the manual stage, we developed a 2-axis automatic stage and experimented on the position repetition accuracy. As a result, it was confirmed that the repeatability of the position of the two-axis stage mounted on the inverted microscope was ± 8.125μm on the X axis and ± 7.75μm on the Y axis. It is expected that the development of more precise stage than μm unit will be possible through the experiment of this paper.
Abstract
In this paper, we propose a method to solve the problems that it is difficult to repeat the characteristics evaluation because it takes a lot of time to obtain the results of experiment or characterization analysis due to passive transfer in biological inverted microscope. It is possible to confirm the entire area of t h e well plate, which is a cell culture container, in a commercialized biological inverted microscope. In order to check the result of the property of the material or cell more quickly and conveniently than the driving time of the manual stage, we developed a 2-axis automatic stage and experimented on the position repetition accuracy. As a result, it was confirmed that the repeatability of the position of the two-axis stage mounted on the inverted microscope was ± 8.125μm on the X axis and ± 7.75μm on the Y axis. It is expected that the development of more precise stage than μm unit will be possible through the experiment of this paper.
참고문헌 (8)
- Lund, J. W. G., "The inverted microscope method of estimating agal numbers and the statistical basis of estimations by counting", Hydrobiologia, 11(2), pp.143~170 (1958)[DOI]
- Sandgren, C. D., "A stratified sampling approach to compensating for non-random sedimentation of phytoplankton cells in inverted microscope settling chambers", British Phycological Journal, 19(1), pp.67~72 (1984)[DOI]
- Bavister, B. D, "A minichamber device for maintaining a constant carbon dioxide in ari atmosphere during prolonged culture of cells on the stage of an inverted microscopes", In Vitro Cellular & Developmental Biology, 24(8), pp.759~763 (1988)[DOI]
- Inoue, Y., "Method for micromanipulating cells by moving cell-containing vessel on stage of inverted microscope while pricking cells with tip of stylus. U.S. Patent No. 4, 920, 053", ~ (1990)
- Datyner, N. B., "Versatile temperature controlled tissue bath for studies of isolated cells using an inverted microscope", Pflugers Archiv, 403(3), pp.318~323 (1985)[DOI]
- Crowe, W. E., "A simple method for monitoring changes in cell height using fluorescent microbeads and an Ussing-type chamber for the inverted microscope", Pflugers Archiv, 419(3), pp.349~357 (1991)[DOI]
- Zimic, M., "Development of Low-Cost Inverted Microscope to Detect Early Growth of Mycobacterium tuberculosis in MODS Culture", PLoS ONE, 5(3), pp.67~72 (2010)
- Heidemann, S. R., "Open-dish incubator for live cell imaging with an inverted microscope", Bio Techniques, 35(4), pp.708~716 (2003)