Horner plot을 이용한 열응답 실험 해석
Application of the Horner plot method in thermal response test interpretation
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The selection of TRT and its interpretation method are important to design an economical geothermal heat pump system because heat exchange rate of a borehole heat exchanger system highly depends on effective thermal conductivity of ground.Two thermal response tests (TRTs) are performed in a 200 m long vertical closed-loop borehole heat exchanger, and thermal conductivities are estimated with a conventional method using the line source theory, and the Horner plot method. The Horner plot method is applied to recovered circulation fluid temperatures during fluid circulation after power shut-in, and recovered ground temperatures were measured by a fiber optic temperature sensing method. The estimated thermal conductivity using the conventional method is 2.75W/m/K, and that using the Horner plot method is 2.87 W/m/K. The average effective thermal conductivity using the Horner plot method with fiber optic temperature sensing data is 2.88 W/m/K and the average core sample thermal conductivity measured in a lab is 2.90 W/m/K. By comparison of each results with core thermal conductivity data, three different interpretation methods show reliable results.
Abstract
The selection of TRT and its interpretation method are important to design an economical geothermal heat pump system because heat exchange rate of a borehole heat exchanger system highly depends on effective thermal conductivity of ground.Two thermal response tests (TRTs) are performed in a 200 m long vertical closed-loop borehole heat exchanger, and thermal conductivities are estimated with a conventional method using the line source theory, and the Horner plot method. The Horner plot method is applied to recovered circulation fluid temperatures during fluid circulation after power shut-in, and recovered ground temperatures were measured by a fiber optic temperature sensing method. The estimated thermal conductivity using the conventional method is 2.75W/m/K, and that using the Horner plot method is 2.87 W/m/K. The average effective thermal conductivity using the Horner plot method with fiber optic temperature sensing data is 2.88 W/m/K and the average core sample thermal conductivity measured in a lab is 2.90 W/m/K. By comparison of each results with core thermal conductivity data, three different interpretation methods show reliable results.
참고문헌 (28)
- 박정민, "경기도, 강원도, 충청도 일대의 암석 열물성 특성 연구", 자원환경지질, 40(6), pp.761~769 (2007), 대한자원환경지질학회
- 손병후, "지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정", 설비공학 논문집, 17(8), pp.695~703 (2005), 대한설비공학회
- 손병후, "단순 선형열원 모델을 이용한 지중 유효열전도도와 보어홀 유효 열저항 산정", 설비공학논문집, 19(7), pp.512~520
- 심병완, "대수층 축열 에너지 시스템에서 지하수 유동 영향에 의한 지반내 온도 분포 예측 시뮬레이 션", 한국지열에너지학회 논문집, 1(1), pp.1~8 (2005)
- 심병완, "지중 열교환기 효율 분석을 위한 지반내 열적.수리적 특성 조사", 한국지구시스템공학회지, 43(2), pp.97~105 (2006), 한국지구시스템공학회
- 에너지관리공단 신・재생에너지센터, "신 재생에너지 RD&D 2030 전략", 258~ (2007)
- 이명택, "동특성 시뮬레이션을 통한 지하수 열원 열펌프 성능 분석", 대한설비공학 회 하계학술발표대회 논문집, pp.1125~1130 (2005)
- Busso, A., "“Underground thermal energy storage - First thermal response test in South Africa,” RIO 3 - World Climate and Energy Event, Rio de Janeiro, Brazil, pp. 189-196", ~ (2003)
- Carslaw, H. S., "Conduction of heat in Solids, 2nd ed", pp.520~ (1986), Oxford University Press
- Espinosa-Paredes, G., "Estimation of static formation temperatures in geothermal wells", Energy conversion & management, 44, pp.1343~1355 (2003)
- Förster, A., "Application of optical-fiber temperature logging-An example in a sedimentary environment", Geophysics, 62(4), pp.1107~1113 (1997)
- Fujii, H., "Practice and interpretation of thermal response test, Lecture note: Geothermal heat pump system", Journal of Geothermal resources society of Japan, 28(2), pp.245~257 (2006)
- Fujii, H., "Analysis of thermal response test of heat exchange wells in ground-coupled heat pump systems", 資源と素材, 118, pp.75~80 (2002)
- Gehlin, S., "Thermal response test - In-situ measurements of thermal properties in hard rock, Lulea University of Technology, Sweden. p. 21", ~ (1998)
- Gehlin, S., "Thermal response test - Method development and evaluation, Doctoral Thesis 2002:39, Lulea University of Technology, Sweden. p.43", ~ (2002)
- Gro wig, S., "Fibre optic β temperature sensing: A new tool for temperature measurements in borehole", Geophysics, 61(4), pp.1065~1067 (1996)
- "Pressure build-up in wells", pp.503~ (1951), Third World Petroleum congress
- Hurtig, E., "Fibre-optic temperature measurements in shallow boreholes: experimental application for fluid logging", Geothermics, 23(4), pp.355~364 (1994)
- Hurtig, E., "Fiber optic β temperature sensing: application for subsurface and ground temperature measurements", Tectonophysics, 257(1), pp.101~109 (1996)
- Ingersoll, L. R., "“Theory of the ground pipe heat source for the heat pump, heatin, piping & air conditioning,” July, pp. 199-122", ~ (1948)
- Signorelli, S., "“Geoscientific investigations for the use of shallow low-enthalpy systems,” Doctoral Thesis, ETH No. 15519, Swiss Federal Institute of Technology Zurich, Switzerland, p. 159", ~ (2004)
- Stober, I., "The upper continental crust, and aquifer and its fluid: hydarulic and chemical data from 4 km depth in fractured crystalline basement rocks at the KTB test site", Geofluids, 5, pp.8~19 (2005)
- Štulc, P, "Return to thermal equilibrium of an intermittently drilled hole: theorgy and experiment", Tectonophysics, 241, pp.35~45 (1995)
- Sung, WM, "The Interpretation of DST Data for Donghae-1 Gas Field", Block VI-1 Korea Korean Journal of Chemical Engineering, 18(1), pp.67~74 (2001)
- VDI, "Thermal use of the underground fundamentals, approvals, environmental aspects, VDI 4640, Part 1~Part 4", ~ (2000)
- Waples, D. W., "Evaluation of Horner plot-corrected log-derived temperatures in the Danish Central Graben, North Sea", Natural Resources Research, 13(4), pp.223~227 (2004)
- Wisian, K. W., "Field comparison of conventional and new technology temperature logging systems", Geothermics, 27(2), pp.131~141 (1998)
