Background and Objectives: We aimed to make a preliminary assessment of the prevalence of cochlear dead regions (DRs) and the factors affecting the results of the threshold-equalizing noise (TEN) test in patients with hearing loss of various etiologies. Subjects and Methods: Between May and July 2014, 109 patients (191 ears) with hearing loss who visited our outpatient clinic were prospectively enrolled. Pure tone audiometry and TEN (HL) test were performed for all the patients. DR at each frequency was indicated by masked thresholds of ≥10 dB above the TEN level and ≥10 dB above the absolute threshold. Results: DR was present in 15.7% (n=30) of the 191 ears. According to disease entity, 16.6% of patients with sensorineural hearing loss had a DR. However, DR was absent in patients with chronic otitis media. According to audiometric configurations, DR was most common in moderately severe, flat hearing loss. Significantly worse hearing thresholds for both mean hearing level and hearing threshold at each frequency were found in the presence of DR (p<0.001). Logistic regression analysis showed that only the mean hearing level (odds ratio: 1.053, 95% confidence interval: 1.021-1.085) affected the presence of DR. Conclusions: Although performance of the TEN test is limited by frequencies and hearing levels, it provides additional information regarding DRs and may therefore have the potential to be used as a prognostic tool for diverse diseases causing hearing loss.
Abstract
Background and Objectives: We aimed to make a preliminary assessment of the prevalence of cochlear dead regions (DRs) and the factors affecting the results of the threshold-equalizing noise (TEN) test in patients with hearing loss of various etiologies. Subjects and Methods: Between May and July 2014, 109 patients (191 ears) with hearing loss who visited our outpatient clinic were prospectively enrolled. Pure tone audiometry and TEN (HL) test were performed for all the patients. DR at each frequency was indicated by masked thresholds of ≥10 dB above the TEN level and ≥10 dB above the absolute threshold. Results: DR was present in 15.7% (n=30) of the 191 ears. According to disease entity, 16.6% of patients with sensorineural hearing loss had a DR. However, DR was absent in patients with chronic otitis media. According to audiometric configurations, DR was most common in moderately severe, flat hearing loss. Significantly worse hearing thresholds for both mean hearing level and hearing threshold at each frequency were found in the presence of DR (p<0.001). Logistic regression analysis showed that only the mean hearing level (odds ratio: 1.053, 95% confidence interval: 1.021-1.085) affected the presence of DR. Conclusions: Although performance of the TEN test is limited by frequencies and hearing levels, it provides additional information regarding DRs and may therefore have the potential to be used as a prognostic tool for diverse diseases causing hearing loss.
참고문헌 (14)
- Moore BC, "A test for the diagnosis of dead regions in the cochlea", Br J Audiol, 34, pp.205~224 (2000)
- Moore BC, "New version of the TEN test with calibrations in dB HL", Ear Hear, 25, pp.478~487 (2004)
- Moore BC, "Testing for cochlear dead regions: audiometer implementation of the TEN (HL) test", Hear Rev, 17, pp.10~16 (2010)
- Cox RM, "Cochlear dead regions in typical hearing aid candidates: prevalence and implications for use of high-frequency speech cues", Ear Hear, 32, pp.339~348 (2011)
- Pepler A, "Prevalence of cochlear dead regions in new referrals and existing adult hearing aid users", Ear Hear, 35, pp.e99~e109 (2014)
- Vinay, "Prevalence of dead regions in subjects with sensorineural hearing loss", Ear Hear, 28, pp.231~241 (2007)
- Sheehy JL, "Vasodilator therapy in sensory-neural hearing loss", Laryngoscope, 70, pp.885~914 (1960)
- Kanda Y, "Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics", Bone Marrow Transplant, 48, pp.452~458 (2013)
- Papp Z, "Sensorineural hearing loss in chronic otitis media", Otol Neurotol, 24, pp.141~144 (2003)
- Summers V, "Identifying dead regions in the cochlea: psychophysical tuning curves and tone detection in threshold-equalizing noise", Ear Hear, 24, pp.133~142 (2003)
- Preminger JE, "A clinical perspective on cochlear dead regions: intelligibility of speech and subjective hearing aid benefit", J Am Acad Audiol, 16, pp.600~613 (2005)
- Hornsby BW, "Factors affecting outcomes on the TEN (SPL) test in adults with hearing loss", J Am Acad Audiol, 20, pp.251~263 (2009)
- Pepler A, "Repeatability, agreement, and feasibility of using the threshold equalizing noise test and fast psychophysical tuning curves in a clinical setting", Int J Audiol, 53, pp.745~752 (2014)
- Warnaar B, "Agreement between psychophysical tuning curves and the threshold equalizing noise test in dead region identification", Int J Audiol, 51, pp.456~464 (2012)