Improving Accuracy and Reliability of Hearing Tests: An Exploration of International Standards
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
This study explores the internal standards for hearing tests and benefits of implementing international standard protocols, including the International Organization for Standardization (ISTO) and International Electrotechnical Commission (IEC), and discusses how ISO and IEC standards provide a framework for designing, calibrating, assessing hearing test instruments and methods, and exchanging and comparing data globally. ISO and IEC standards for hearing tests improve accuracy, reliability, and consistency of test results by applying standardized methods and environments. Moreover, they promote international harmonization and data interoperability, enabling information exchange and research collaboration. Those standards for hearing tests are beneficial but have challenges and limitations, such as variation in equipment and calibration, lag in updating standards, variation in implementation and compliance, and lack of coverage of clinical aspects, cultural diversity, and linguistic diversity. These affect the quality and interpretation of test results. Adapting ISO or IEC standards locally would improve their applicability and acceptability, while balancing customization and compatibility with global standards.
Abstract
This study explores the internal standards for hearing tests and benefits of implementing international standard protocols, including the International Organization for Standardization (ISTO) and International Electrotechnical Commission (IEC), and discusses how ISO and IEC standards provide a framework for designing, calibrating, assessing hearing test instruments and methods, and exchanging and comparing data globally. ISO and IEC standards for hearing tests improve accuracy, reliability, and consistency of test results by applying standardized methods and environments. Moreover, they promote international harmonization and data interoperability, enabling information exchange and research collaboration. Those standards for hearing tests are beneficial but have challenges and limitations, such as variation in equipment and calibration, lag in updating standards, variation in implementation and compliance, and lack of coverage of clinical aspects, cultural diversity, and linguistic diversity. These affect the quality and interpretation of test results. Adapting ISO or IEC standards locally would improve their applicability and acceptability, while balancing customization and compatibility with global standards.
참고문헌 (35)
- International Organization for Standardization, "ISO 8253-1:2010. Acoustics — Audiometric test methods — Part 1: pure-tone air and bone conduction audiometry", International Organization for Standardization, 1~30 (2010)
- Lin FR, "Hearing loss and cognitive decline in older adults", JAMA Intern Med, 173, pp.293~299 (2013)
- Themann CL, "Occupational noise exposure : a review of its effects, epidemiology, and impact with recommendations for reducing its burden", J Acoust Soc Am, 146, pp.3879~3905 (2019)
- Lin FR, "Hearing intervention versus health education control to reduce cognitive decline in older adults with hearing loss in the USA(ACHIEVE) : a multicentre, randomised controlled trial", Lancet, 402, pp.786~797 (2023)
- Niazi Y, "Impact of hearing impairment on psychological distress and subjective well-being in older adults", Pak J Med Sci, 36, pp.1210~1215 (2020)
- "Hearing testing history: Western electric 2-A audiometer" (2015)[URL]
- Fitzgerald MB, "Assessment of hearing during the early years of the American Otological Society", Otol Neurotol, 39(4S Suppl 1), pp.S30~S42 (2018)
- Davis H, "The international standard reference zero for pure-tone audiometers and its relation to the evaluation on impairment of hearing", J Speech Hear Res, 7, pp.7~16 (1964)
- International Organization for Standardization, "ISO 6189:1983. Acoustics — Pure tone air conduction threshold audiometry for hearing conservation purposes", International Organization for Standardization, 1~9 (1983)
- International Organization for Standardization, "ISO 8253-2:2009. Acoustics — Audiometric test methods — Part 2: sound field audiometry with pure-tone and narrow-band test signals", International Organization for Standardization, 1~16 (2009)
- International Organization for Standardization, "ISO 8253-3:2012. Acoustics — Audiometric test methods — Part 3: speech audiometry", International Organization for Standardization, 1~31 (2012)
- International Organization for Standardization, "ISO 389-1:2017. Acoustics — Reference zero for the calibration of audiometric equipment — Part 1: reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones", International Organization for Standardization, 1~10 (2017)
- International Organization for Standardization, "ISO 389-2:1994. Acoustics — Reference zero for the calibration of audiometric equipment — Part 2: reference equivalent threshold sound pressure levels for pure tones and insert earphones", International Organization for Standardization, 1~7 (1996)
- International Organization for Standardization, "Acoustics — Reference zero for the calibration of audiometric equipment — Part 3 : reference equivalent threshold vibratory force levels for pure tones and bone vibrators", International Organization for Standardization, 1~13 (2016)
- International Organization for Standardization, "ISO 389-4:1994. Acoustics — Reference zero for the calibration of audiometric equipment — Part 4: reference levels for narrow-band masking noise", International Organization for Standardization, 1~4 (1994)
- International Organization for Standardization, "ISO 389-5:2006. Acoustics — Reference zero for the calibration of audiometric equipment — Part 5: reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz", International Organization for Standardization, 1~6 (2006)
- International Organization for Standardization, "ISO 389-6:2007. Acoustics — Reference zero for the calibration of audiometric equipment — Part 6: reference threshold of hearing for test signals of short duration", International Organization for Standardization, 1~9 (2007)
- International Organization for Standardization, "ISO 389-7:2005. Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: reference threshold of hearing under free-field and diffuse-field listening conditions", International Organization for Standardization, 1~10 (2005)
- International Organization for Standardization, "ISO 389-8:2004. Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: reference equivalent threshold sound pressure levels for pure tones and circumaural earphones", International Organization for Standardization, 1~7 (2004)
- International Organization for Standardization, "ISO 389-9:2009. Acoustics — Reference zero for the calibration of audiometric equipment — Part 9: preferred test conditions for the determination of reference hearing threshold levels", International Organization for Standardization, 1~9 (2009)
- International Electrotechnical Commission, "IEC 60645-1:2017. Electroacoustics - Audiometric equipment - Part 1: equipment for puretone and speech audiometry", International Electrotechnical Commission, 1~41 (2017)
- International Electrotechnical Commission, "Electroacoustics – Audiometers - Part 2: Equipment for speech audiometry (IEC 60645-2:1993)", International Electrotechnical Commission, 1~37 (1993)
- International Electrotechnical Commission, "IEC 60645-3:2020. Electroacoustics - Audiometric equipment - Part 3: test signals of short duration", International Electrotechnical Commission, 1~14 (2020)
- International Electrotechnical Commission, "IEC 60645-5:2004. Electroacoustics - Audiometric equipment - Part 5: instruments for the measurement of aural acoustic impedance", admittance, 2004, pp.1~57
- International Electrotechnical Commission, "IEC 60645-6:2022. Electroacoustics - Audiometric equipment - Part 6: instruments for the measurement of otoacoustic emissions", International Electrotechnical Commission, 1~17 (2022)
- International Electrotechnical Commission, "IEC 60645-7:2009. Electroacoustics - Audiometric equipment - Part 7: instruments for the measurement of auditory brainstem responses", International Electrotechnical Commission, 1~12 (2009)
- International Electrotechnical Commission, "IEC 60318-1:2009. Electroacoustics - Simulators of human head and ear - Part 1: ear simulator for the measurement of supra-aural and circumaural earphones", International Electrotechnical Commission, 1~25 (2009)
- International Electrotechnical Commission, "IEC 60318-3:2014. Electroacoustics - Simulators of human head and ear - Part 3: acoustic coupler for the calibration of supra-aural earphones used in audiometry", International Electrotechnical Commission, 1~12 (2010)
- International Electrotechnical Commission, "IEC 60318-4:2010. Electroacoustics - Simulators of human head and ear - Part 4: occludedear simulator for the measurement of earphones coupled to the ear by means of ear inserts", International Electrotechnical Commission, 1~19 (2010)
- International Electrotechnical Commission, "IEC 60318-5:2006. Electroacoustics - Simulators of human head and ear - Part 5: 2 cm3 coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts", International Electrotechnical Commission, 1~27 (2006)
- International Electrotechnical Commission, "IEC 60318-6:2007. Electroacoustics - Simulators of human head and ear - Part 6: mechanical coupler for the measurement on bone vibrators", International Electrotechnical Commission, 1~15 (2007)
- International Electrotechnical Commission, "IEC 60318-7:2022. Electroacoustics – Simulators of human head and ear – Part 7: Head and torso simulator for the measurement of sound sources close to the ear", International Electrotechnical Commission, 1~32 (2007)
- Joint Committee for Guides in Metrology, "ISO", IEC guide 98-3:2008. Uncertainty of measurement — Part 3: guide to the expression of uncertainty in measurement (GUM:1995), 2008, pp.1~120
- Young A, "Otoacoustic emissions" (2023), StatPearls Publishing
- Burkard RF, "Auditory evoked potentials : basic principles and clinical application" (2007), Lippincott Williams & Wilkins