Investigation of condensation with non-condensable gas in natural circulation loop for passive safety system
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.
Abstract
The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.
참고문헌 (13)
- Passive Safety Systems and Natural Circulation in Water Cooled Nuclear Power Plants, "INTERNATIONAL ATOMIC ENERGY AGENCY", ~, pp.IAEA-TECDOC-1624 (2006)
- K. H. Bae, "Enhanced safety characteristics of SMART100 adopting passive safety systems", Nucl. Eng. Des, 379, pp.111247~ (2021)
- Local Heat-Transfer Coefficients and Static Pressures for Condensation of High-Velocity Steam within a Tube, "J.H. Goodykoontz", NASA, 3953~ (1967)
- K.M. Vierow, "Behavior of Steam-Air Systems Condensing in Concurrent Vertical Downflow", M.S., pp.1990
- H. S. Park, "A condensation experiment in the presence of noncondensibles in a vertical tube of a passive containment cooling system and its assessment with RELAP5", MOD3.2, 1999, pp.127(2), 160~169
- S. J. Kim, "Turbulent film condensation of high pressure steam in a vertical tube", Int. J. Heat Mass Tran, 43(21), pp.4031~4042 (2000)
- S. Oh, "Effect of noncondensible gas in a vertical tube condenser", Nucl. Eng. Des, 235(16), pp.1699~1712 (2005)
- K. Y. Lee, "Experimental and empirical study of steam condensation heat transfer with a noncondensible gas in a small-diameter vertical tube", Nucl. Eng. Des, 238(1), pp.207~216 (2008)
- K.M. Vierow, "Condensation in a natural circulation loop with noncondensable gases, 1", Proceedings of the International Conference on Multiphase Flows, 1, pp.24~27 (1991)
- K.M. Vierow, "Condensation in a natural circulation loop with noncondensable gases, 2", Proceedings of the International Conference on Multiphase Flows, 2, pp.24~27 (1991)
- J.H. Yang, "3D bubble reconstruction method for direct contact condensation phenomena on elbow tip", The 9th China-Korea Workshop on Nuclear Reactor Thermal-Hydraulics (WORTH-9), 15-18 (2019)
- J. H. Yang, "Condensation Experiments with Noncondensable Gas in Closed Loop Using Local Measurement Method", the 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19), 6-11 (2022)
- Similarity analysis and scaling criteria for LWRs under single-phase and two-phase natural circulation, "M. Ishii", Argonne National Laboratory, ~, pp.ANL-83-32 or NUREG (1983), CR-3267