Fluidelastic instability of a curved tube array in single phase cross flow
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6x9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability
Abstract
Experimental study on the fluidelastic instability (FEI) of a curved tube bundle in single phase downward cross flow is investigated for the design qualification and analysis input preparation of helical coiled steam generator tubing. A 6x9 normal square curved tube array with equal and different vertical/horizontal pitch-to-diameter ratio was under-tested up to 6 m/s in term of gap flow velocity to measure the critical velocity for FEI. The critical velocity for FEI was measured at the turning point from the vibration amplitude plot along the gap flow velocity. Our test results were compared with straight tube results and published data in the design guideline. The applicability of the current design guidelines to a curved tube bundle is also assessed. We found that introducing frequency difference in a curved tube array increases the critical velocity for fluidelastic instability
참고문헌 (15)
- H.J. Connors, "Flow-Induced Vibrations in Heat Exchangers", pp.42~56 (1970), ASME
- S. S. Chen, "Guidelines for the instability flow velocity of tube arrays in cross flow", J. Sound Vibration, 93, pp.439~455 (1984)
- M. K. Au-Yang, "Flow-Induced Vibration of Power and Process Plant Components", pp.63~107 (2001), ASME Press
- M. Pettigrew, "Vibration analysis of shell-and-tube heat exchangers:an overviewdPart 1: flow, damping, fluidelastic instability", J. Fluids Structur, 18, pp.469~483 (2003)
- M. J. Pettigrew, "Flow-induced vibration : recent findings and open questions", Nuclear Eng. Design, 185, pp.249~276 (1995)
- D. S. Weaver, "A review of cross-flow induced vibrations in heat exchanger tube arrays", J. Fluids Structur, 2, pp.73~93 (1988)
- S. J. Price, "A review of theoretical models for fluidelastic instability of cylinder arrays in cross-flow", J. Fluids Structur, 9, pp.463~518 (1995)
- M. D. Blevins, "Flow-Induced Vibration" (1990), Van Nostrand Reinhold
- S. S. Chen, "Flow-induced Vibration of Circular Cylindrical Structures", pp.386~434 (1987), Hemisphere publishing corporation
- M. J. Pettigrew, "Flow-induced Vibration Handbook for Nuclear and Process Equipment", pp.183~266 (2021), ASME Press and John Wiley &Sons, Inc
- M. K. Au-Yang, "Flow-induced vibration analysis of tube bundles-a proposed section III appendix N nonmandatory code", J. Pressure Vessel Technol, 113, pp.257~267 (1991)
- "Appendices N-1300, ASME Section III Division I, Flow-Induced Vibration of Tubes and Tube Banks", ~ (2007)
- S. H. Lee, "Analysis of SGTR accident with Mihama unit experience", J. Korean Nuclear Soc, 26(1) (1994)
- R. D. Blevins, "Nonproprietary flow-induced vibration analysis of san onofre nuclear generating station replacement steam generators to ASME code section III appendix N", J. Pressure Vessel Technol, 140, pp.034502-1~034502-5 (2018)
- San Onofre Nuclear Generating Station Unit 2 Return to Service Report, "S.C. E", Southern California Edison, ~, pp.Technical Docket No. 50-361 (2013)