Beam position measurement system can not only provide the beam position monitoring, but also be used for global orbit correction to reduce beam loss risk and maximize acceptance. The Beam Position Monitors (BPM) are installed along the synchrotron to acquire beam position with the front-end electronics and data acquisition system (DAQ). To realize high precision orbit measurement in the main heavy ion synchrotron and cooling storage ring of heavy-ion research facility in Lanzhou (HIRFL-CSRm), a series of alignment and calibration work has been implemented on the BPM and its DAQ system. This paper analyzed the tests performed in the laboratory as well as with beam based on the developed algorithms and hardware. Several filtering algorithms were designed and implemented on the acquired BPM raw data, then the beam position and resolution were calculated and analyzed. The results show that the position precision was significantly improved from more than 100 μm to about 50 μm by implementing the new designed filtering algorithm. According to the analyzation of the measurement results and upcoming physical requirements, further upgrade scheme for the BPM DAQ system of CSRm based on field programmable gate array (FPGA) technology was proposed and discussed.

Abstract

Beam position measurement system can not only provide the beam position monitoring, but also be used for global orbit correction to reduce beam loss risk and maximize acceptance. The Beam Position Monitors (BPM) are installed along the synchrotron to acquire beam position with the front-end electronics and data acquisition system (DAQ). To realize high precision orbit measurement in the main heavy ion synchrotron and cooling storage ring of heavy-ion research facility in Lanzhou (HIRFL-CSRm), a series of alignment and calibration work has been implemented on the BPM and its DAQ system. This paper analyzed the tests performed in the laboratory as well as with beam based on the developed algorithms and hardware. Several filtering algorithms were designed and implemented on the acquired BPM raw data, then the beam position and resolution were calculated and analyzed. The results show that the position precision was significantly improved from more than 100 μm to about 50 μm by implementing the new designed filtering algorithm. According to the analyzation of the measurement results and upcoming physical requirements, further upgrade scheme for the BPM DAQ system of CSRm based on field programmable gate array (FPGA) technology was proposed and discussed.

참고문헌 (25)

  1. Beam position monitors, "Forck P", CAS - CERN Accelerator School, Beam Diagnostics, 187~ (2009)
  2. W.Z. Zhang, "RF system at HIRFL-CSR mian ring", Cyclotrons and Their Applications, Sixteenth International Conference (2001)
  3. Y. He, Z. J, "Conceptual design of linear injector for SSC of HIRFL", Linear Accelerator Conference LINAC2010 (2010)
  4. He Yuan, "Progress of linear injector for SSC at HIRFL", International Particle Accelerator Conference (2011)
  5. "HIRFL begins operation with continuous wave linac injector"[URL]
  6. Ruishi Mao, "The Closed-Orbit Measurement System of CSR", PhD, pp.2008
  7. R. Singh, "Tune Measurement at GSI SIS-18: Methods and Applications", PhD, pp.2014
  8. D. Bulfone, "Overview of fast beam position feedback systems", Proceedings of EPAC08 (2008)
  9. Closed Orbit Correction Using Singular Value Decomposition of the Response Matrix, "Y. Chung", Argonne National Laboratory, ~ (1993)
  10. Sajjad Hussain Mirza, "Performance of closed orbit feedback systems with spatial model mismatch", Physical Review Accelerators and Beams, 23, pp.072801~ (2020)
  11. "Introduction and materials of PXIe-5105"[URL]
  12. N. Hayashi, "Beam position monitor system of J-PARC RCS", Nucl. Instrum. Methods Phys. Res. A, 677, pp.94~106 (2012)
  13. Silvia Zorzetti, "Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretched-wire RF measurements", Measurement Science and Technology, 26(9), pp.094005~ (2015), IOP Publishing[DOI]
  14. M. Cargnelutti, "EVALUATION OF LIBERA SINGLE PASS H FOR ESS LINAC", IBIC (2014)
  15. P. Kowina, "Pre-amplifier impedance matching for cryogenic BPMs", Proceedings of the 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (2011)
  16. Min Li, "Upgrade of CSRe beam diagnostic control system based on EPICS", High Power Laser Part Beams, 31(12) (2019)
  17. "Exponentially weighted moving average control charts"[URL]
  18. A. B. Yeh, "EWMA control charts for monitoring high-yield processes based on non-transformed observations", Int. J. Prod. Res, 46(20), pp.5679~5699 (2008)
  19. "Moving Average (MA)"[URL]
  20. Houjin Chen, "Digital Signal Processing" (2018), Higher Education Press
  21. Xiaojuan Wei, "An improved method of bunch-by-bunch beam position calculation in a heavy-ion synchrotron", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1021, pp.165947~ (2022), Elsevier BV[DOI]
  22. "Which is the cut-off frequency of moving average LP filter?"[URL]
  23. A. Reiter, "Comparison of beam position calculation methods for application in digital acquisition systems", Nucl. Instrum. Methods Phys. Res. A, 890, pp.18~27 (2018)
  24. "EPICs introduction"[URL]
  25. [URL]

관련 논문AI추천

Slow control system of the HIRFL-CSR external-target experimentDong Jinmei, Li Min, Li Peng, Li Weilong, Mao Ruishi, Yuan Youjin, Yu Yuhong, Zhang Yuqiao, Zhou Kai한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Analysis of fringe field effects on measurement errors for Q-scanning-based emittance diagnosis systemHu H., Hu T.N., Wang Y., Zeng Y.F.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Concurrent operation of round beam and flat beam in a low-emittance storage ring신승환, Ahn S., Chung M., Jang G., Kim J.-H., Ko J., Lee J., Oh B., Yoon Y.D.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제10호Slow control system of CEE-TPCLi Min, Li Peng, Li Weilong, Mao Ruishi, Wei Xianglun, Yang Herun, Yang Yuansheng, You Kejie, Yu Yuhong, Zhang Yuqiao, Zhao Hongyun, Zhou Kai한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제10호Low beta superconducting cavity system design for HIAF iLinacBai Feng, Guo Hao, He Yuan, Huang Qitong, Huang Shichun, Jiang Tiancai, Liang Zehua, Li Chunlong, Liu Lubei, Liu Tong, Li Xiaoli, Tao Yue, Wang Fengfeng, Wang Zhijun, Xu Mengxin, Xu Xianbo, Yang Jiancheng, Zaplatin Evgeny, Zhang Shenghu, Zhang Shengxue한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제7호Development of magnetic field measurement system for AMS cyclotron남궁호, 송호승, 이종철, 채종서, 최효정, 하동협, 미트라게게르치, Mustafa Mumyapan한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제8호