초록
A high-accuracy magnetic field measurement device based on a cyclotron is being developed for accelerator mass spectrometry (AMS). In this study, a magnetic field measurement device consisting of a Hall probe sensor, piezo-motor, and step motor was developed to measure the magnetic field of the AMS cyclotron magnet. The Hall probe sensor was calibrated to achieve positional accuracy by using polar coordinates. The measurement results between the ratchet gear and piezo-motor, which are the instruments used for driving the measurement device, were analyzed. The measurement result of the device with a piezo-motor exhibits a difference of 5 Gauss (0.04%) as compared with the simulation result.
Abstract
A high-accuracy magnetic field measurement device based on a cyclotron is being developed for accelerator mass spectrometry (AMS). In this study, a magnetic field measurement device consisting of a Hall probe sensor, piezo-motor, and step motor was developed to measure the magnetic field of the AMS cyclotron magnet. The Hall probe sensor was calibrated to achieve positional accuracy by using polar coordinates. The measurement results between the ratchet gear and piezo-motor, which are the instruments used for driving the measurement device, were analyzed. The measurement result of the device with a piezo-motor exhibits a difference of 5 Gauss (0.04%) as compared with the simulation result.
참고문헌 (18)
- R. Hellborg, "Accelerator mass spectrometry", Mass Spectrom. Rev, 27(5), pp.398~427 (2008)
- W. E. Kieser, "The Andre E. Lalonde AMS Laboratoryethe new accelerator mass spectrometry facility at the University of Ottawa", Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 361, pp.110~114 (2015)
- J. J. Livingood, "Principles of cyclic particle accelerators", Phys. Today, 15(5), pp.57~ (1962)
- S. Y. Jung, "Central region of SKKUCY-9 compact cyclotron", J. Instrum, 9(4), pp.T04005~ (2014)
- J. Zhong, "The physics design of magnet in 14 MeV cyclotron", Sci. China Phys. Mech. Astron, 54(2), pp.266~270 (2011)
- J. Kang, "Magnet design of the superconducting cyclotron for carbon therapy", IEEE Trans. Appl. Supercond, 22(3), pp.4401104~4401104 (2011)
- K. H. Park, "Field mapping system for cyclotron magnet", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 545(3), pp.533~541 (2005)
- S. Cirkovic, "Minimization of the measurement errors induced by the cyclotron magnetic field measurement system", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 679, pp.54~60 (2012)
- F.S. Grillet, "Magnetic field mapping of the best 70 MeV cyclotron", Proceedings of Cyclotrons, pp.239~241 (2013)
- 이병노, "Development of a Magnetic Field Measurement Instrument for Compact Cyclotrons", Journal of the Korean Physical Society, 61(2), pp.197~202 (2012), 한국물리학회[DOI]
- M. Fan, "Measurement and adjustment of CIAE medical cyclotron magnet", Proceedings of International Conference On Particle Accelerators, pp.2841~2843 (1993), IEEE
- T. Hemsel, "Survey of the present state of the art of piezoelectric linear motors", Ultrasonics, 38(1-8), pp.37~40 (2000)
- K. Spanner, "Piezoelectric motors, an overview", Actuators, 5(1), pp.6~ (2016)
- Field Measurements, "L. Bottura", CERN, ~, pp.No. CERN-LHC-2002-020-MTA (2002)