초록
The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a highresolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 mm were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 mm airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 mm of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.
Abstract
The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a highresolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 mm were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 mm airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 mm of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.
참고문헌 (30)
- S. Choi, "Characteristics of aerosols from different metals with plasma arc torch", Aerosol Technology (2018)
- N. Chae, "Aerodynamic diameter and radioactivity distributions of radioactive aerosols from activated metals cutting for nuclear power plant decommissioning", J. Hazard Mater, 369, pp.727~745 (2019)
- Size Distribution and Rate of Production of Airborne Particulate Matter Generated during Metal Cutting, "M. Ebadian", National Energy Technology Lab, National Energy Technology Lab, ~ (2001)
- M. H. Lee, "Aerodynamic diameter distribution of aerosols from plasma arc cutting for steels at different cutting power levels", J. Radioanal. Nucl. Chem, 323, pp.613~624 (2020)
- N. Chae, "Review on radioactive aerosols from decommissioning on nuclear power plant", International Youth Nuclear Congress (2018)
- 이민호, "High resolution size characterization of particulate contaminants for radioactive metal waste treatment", Nuclear Engineering and Technology, 53(7), pp.2277~2288 (2021), 한국원자력학회[DOI]
- 이민호, "Performance assessment of HEPA fi lter against radioactive aerosols from metal cutting during nuclear decommissioning", Nuclear Engineering and Technology, 52(5), pp.1043~1050 (2020), 한국원자력학회[DOI]
- R. A. Sadir, "Clean Room Technology in ART Clinics", pp.75~84 (2016), CRC Press
- IAEA, "Mobile Processing Systems for Radioactive Waste Management" (2014)
- W. J. Kowalski, "Filtration of airborne microorganisms : modeling and prediction", Build. Eng, 105, pp.4~17 (1999)
- S. L. Alderman, "Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters", J. Occup. Environ. Hyg, 5(11), pp.713~720 (2008)
- G. Smith, "Nuclear Air Cleaning Handbook" (2003), U.S. DOE
- J. Gustavsson, "Air Filtration in HVAC Systems, REHVA guidebook" (2010)
- D. Q. Chang, "Factors affecting particle depositions on electret filters used in residential HVAC systems and indoor air cleaners", Aerosol Air Qual. Res, 18, pp.3211~3219 (2018)
- J. H. Vincent, "Aerosol Sampling: Science, Standards, Instrumentation and Applications" (2007), John Wiley & Sons
- R. Baskaran, "Aerosol characterization and measurement techniques towards SFR safety studies", First International Conference on ANIMMA (2009), IEEE
- Z. Q. Yin, "Thermophoresis and Brownian motion effects on nanoparticle deposition inside a 90 square bend tube", Aerosol Air Qual. Res, 18(7), pp.1746~1755 (2018)
- T. Sparks, "Filters and Filtration Handbook" (2016), Butterworth-Heinemann
- R. Mostofi, "Impact of two particle measurement techniques on the determination of N95 class respirator filtration performance against ultrafine particles", J. Hazard Mater, 217-218, pp.51~57 (2012)
- P. Penicot, "Clogging of HEPA fibrous filters by solid and liquid aerosol particles : an experimental study", Filtrat. Separ, 36(2), pp.59~64 (1999)
- F. X. Ouf, "Clogging of industrial High Efficiency Particulate Air(HEPA)filters in case of fire : from analytical to large-scale experiments", Aerosol. Sci. Technol, 48(9), pp.939~947 (2014)
- In-place HEPA Filter Penetration Test, "W. Bergman", Lawrence Livermore National Lab, ~, pp.UCRL-JC-127230;CONF-960715 (1997)
- S. Saari, "Performance evaluation of the HR-ELPIþ inversion", Aerosol. Sci. Technol, 52(9), pp.1037~1047 (2018)
- A. Jarvinen, "Calibration of the new electrical low pressure impactor(ELPI+)", J. Aerosol Sci, 69, pp.150~159 (2014)
- H. J. Choi, "Preparation of electrospun polyurethane filter media and their collection mechanisms for ultrafine particles", J. Air Waste Manage. Assoc, 64, pp.322~329 (2014)
- S. H. Huang, "Factors affecting filter penetration and quality factor of particulate respirators", Aerosol Air Qual. Res, 13(1), pp.162~171 (2013)
- ICRP, "ICRP publication 68: dose coefficients for intakes of radionuclides by workers", Ann. ICRP, pp.24~ (1994)
- ICRP, "ICRP Publication 66: human respiratory tract model for radiological protection", Ann. ICRP, pp.24~ (1994)
- A. Joubert, "Modelling the pressure drop across HEPA filters during cake filtration in the presence of humidity", Chem. Eng. J, 166(2), pp.616~623 (2011)
- W. Zhang, "Dust loading performance of the PTFE HEPA media and its comparison with the glass fibre HEPA media", Aerosol Air Qual. Res, 18, pp.1921~1931 (2018)