Radioactive gas diffusion simulation and inhaled effective dose evaluation during nuclear decommissioning
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
During the decommissioning of the nuclear facilities, the radioactive gases in pressure vessels may leakdue to the demolition operations. The decommissioning site has large space, slow air circulation, andmany large nuclear facilities, which increase the difficulty of workers' inhalation exposure assessment. Inorder to dynamically evaluate the activity distribution of radionuclides and the committed effective dosefrom inhalation in nuclear decommissioning environment, an inhalation exposure assessment methodbased on the modified eddy-diffusion model and the inhaled dose conversion factor is proposed in thispaper. The method takes into account the influence of building, facilities, exhaust ducts, etc. on thedistribution of radioactive gases, and can evaluate the influence of radioactive gases diffusion on workersduring the decommissioning of nuclear facilities.
Abstract
During the decommissioning of the nuclear facilities, the radioactive gases in pressure vessels may leakdue to the demolition operations. The decommissioning site has large space, slow air circulation, andmany large nuclear facilities, which increase the difficulty of workers' inhalation exposure assessment. Inorder to dynamically evaluate the activity distribution of radionuclides and the committed effective dosefrom inhalation in nuclear decommissioning environment, an inhalation exposure assessment methodbased on the modified eddy-diffusion model and the inhaled dose conversion factor is proposed in thispaper. The method takes into account the influence of building, facilities, exhaust ducts, etc. on thedistribution of radioactive gases, and can evaluate the influence of radioactive gases diffusion on workersduring the decommissioning of nuclear facilities.
참고문헌 (9)
- C. Keil, "An application of exposure modeling in exposure assessments for a university chemistry teaching laboratory", J. Occup. Environ. Hyg, 3(2), pp.99~106 (2006)
- J. Spencer, "A comparison study using a mathematical model and actual exposure monitoring for estimating solvent exposures during the disassembly of metal parts", J. Occup. Environ. Hyg, 4(4), pp.7~ (2007)
- E. Demou, "Evaluating indoor exposure modeling alternatives for lca : a case study in the vehicle repair industry", Environ. Sci. Technol, 43(15), pp.5804~5810 (2009)
- P. J. Drivas, "Modeling indoor air exposure from short-term point source releases", Indoor Air, 6(4), pp.271~277 (1996)
- P. A. Scheff, "Emission factors for trichloroethylene vapor degreasers", American Indsutrial Hygiene Association, 50(9), pp.496~500 (1989)
- C. Keil, "Mathematical Models for Estimating Occupational Exposure to Chemicals", American Indsutrial Hygiene Association (2000)
- B. C. Keil, "A tiered approach to deterministic models for indoor air exposures", Appl. Occup. Environ. Hyg, 15(1), pp.145~151 (2000)
- L. Q. Yang, "A gamma-ray dose rate assessment method for arbitrary shape geometries based on voxelization algorithm", Radiat. Phys. Chem, 158, pp.122~130 (2019)
- G. Wang, "Adoption of lung absorption type for radionuclides based upon a national standard", Radiat. Protect, 33(4), pp.253~256 (2013)
