Evaluation by thickness of a linear accelerator target at 6-20 MeV electron beam in MCNP6
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study quantitatively evaluated the source term of a linear accelerator according to target thickness for a 6-20 MeV electron beam using MCNP6. The elements of the target were tungsten and copper, and a composite target and single target were simulated by setting different thickness parameters depending on energy. The accumulation of energy generated through interaction with the collided target was evaluated at 0.1-mm intervals, and F6 tally was used. The results indicated that less than 3% reference error was maintained according to the MCNP recommendations. At 6, 8, 10, 15, 18, and 20 MeV, the energy accumulation peaks identified for each target were 0.3 mm in tungsten, 1.3 mm in copper, 1.5 mm in copper, 0.5 mm in tungsten, 0.5 mm in tungsten, and 0.5 mm in tungsten. For 8 and 10 MeV in a single target consisting only of copper, the movement of electrons was confirmed at the end of the target, and the proportion of escaped electrons was 0.00011% and 0.00181%, respectively
Abstract
This study quantitatively evaluated the source term of a linear accelerator according to target thickness for a 6-20 MeV electron beam using MCNP6. The elements of the target were tungsten and copper, and a composite target and single target were simulated by setting different thickness parameters depending on energy. The accumulation of energy generated through interaction with the collided target was evaluated at 0.1-mm intervals, and F6 tally was used. The results indicated that less than 3% reference error was maintained according to the MCNP recommendations. At 6, 8, 10, 15, 18, and 20 MeV, the energy accumulation peaks identified for each target were 0.3 mm in tungsten, 1.3 mm in copper, 1.5 mm in copper, 0.5 mm in tungsten, 0.5 mm in tungsten, and 0.5 mm in tungsten. For 8 and 10 MeV in a single target consisting only of copper, the movement of electrons was confirmed at the end of the target, and the proportion of escaped electrons was 0.00011% and 0.00181%, respectively
참고문헌 (15)
- Global Market Trend Report - Radiation Therapy Market, "Daedeok Innopolis Foundation", 05~ (2021)
- D.I. Thwaites, "Back to the future: the history and development of the clinical linear accelerator", Phys. Med. Biol, 51, pp.R343~R362 (2006)
- J. D. Graham, "A comparison of techniques for stereotactic radiotherapy by linear accelerator based on 3-dimensional dose distributions", Radiother. Oncol, 22, pp.29~35 (1991)
- 이창호, "MCNP6 코드를 이용한 컨테이너 보안 검색용 전자 선형가속기 표적에서 발생한 광자 평가에 관한 연구", 한국방사선학회논문지, 14(3), pp.193~201 (2020), 한국방사선학회[DOI]
- 이창호, "컨테이너 보안 검색용 9 MeV 전자 선형가속기에서 발생한 방사화 특성평가에 관한 연구", 한국방사선학회논문지, 14(5), pp.563~575 (2020), 한국방사선학회[DOI]
- A. Mesbahi, "Effect of wedge filter and field size on photoneutron dose equivalent for an 18 MV photon beam of a medical linear accelerator", Appl. Radiat. Isot, 68, pp.84~89 (2010)
- H. S. Kim, "Evaluation of the photoneutron field produced in a medical linear accelerator", Radiat. Prot. Dosim, 123, pp.323~328 (2007)
- L. Montgomery, "The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator", Med. Phys, 45, pp.4711~4719 (2018)
- Kjeld J. Olsen, "Neutron contamination from medical electron accelerators (NCRP report No. 79)", Med. Phys, 13, pp.968~969 (1986)
- T. Goorley, "Initial MCNP6 release overview", Nucl, 180, pp.298~315 (2012)
- Q. Gao, "Design and optimization of the target in electron linear accelerator", Carbon, 1, pp.0~05 (2013)
- W. L. Huang, "Calculation of photoneutrons produced in the targets of electron linear accelerators for radiography and radiotheraphy applications", Nucl. Instrum. Methods Phys. Res. B NUCL, 229, pp.339~347 (2005)
- Varian Oncology Systems, "MONTE CARLO MODELING - High Energy Accelerator Platform 26", ~
- F. A. A. Ajaj, "An MCNP-based model of a medical linear accelerator x-ray photon beam", Australas Phys. Eng. Sci. Med, 26, pp.140~144 (2003)
- Z. Fardi, "A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media", Pol. J. Med. Phys. Eng, 25, pp.15~22 (2019)
