Current Status of Disposal and Measurement Analysis of Radioactive Components in Linear Accelerators in Korea

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류원자력공학

초록

When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction,which activates the components of linear accelerator (linac). Safely managing the radioactive material,when disposing linac or replacing components, is difficult, as the standards for the radioactive materialmanagement are not clear in Korea. We surveyed the management status of radioactive componentsoccurred from medical linacs in Korea. And we also measured the activation of each part of the discardedElekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found thatmost medical institutions did not perform radiation measurements when disposing of radioactivecomponents. The radioactive material was either stored within the institution or collected by themanufacturer. The surface dose rate measurements showed that the parts with high surface dose rateswere target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts,whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions inKorea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclidesand to lay the foundation for radioactive waste management from medical linacs

Abstract

When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction,which activates the components of linear accelerator (linac). Safely managing the radioactive material,when disposing linac or replacing components, is difficult, as the standards for the radioactive materialmanagement are not clear in Korea. We surveyed the management status of radioactive componentsoccurred from medical linacs in Korea. And we also measured the activation of each part of the discardedElekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found thatmost medical institutions did not perform radiation measurements when disposing of radioactivecomponents. The radioactive material was either stored within the institution or collected by themanufacturer. The surface dose rate measurements showed that the parts with high surface dose rateswere target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts,whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions inKorea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclidesand to lay the foundation for radioactive waste management from medical linacs

참고문헌 (34)

  1. "National Cancer Institute, National Institutes of Health, Cancer Treatment" (2021)[URL]
  2. 이창걸, "증상완화목적의 방사선치료", Journal of Hospice and Palliative Care, 12(1), pp.1~4 (2009), 한국호스피스완화의료학회
  3. 허승재, "Current status and comparison of national health insurance systems for advanced radiation technologies in Korea and Japan", Radiation oncology journal, 38(3), pp.170~175 (2020), 대한방사선종양학회
  4. Radiation therapy device Technology trend and Industry status, "Korea Evaluation Institute of Industrial Technology", KEIT, 40~54, pp.KEIT PD Issue report, 17 (2017)
  5. David A. Jaffray, "Radiation Therapy for Cancer", Disease Control Priorities, Third Edition (Volume 3): Cancer, pp.239~247 (2015), The World Bank[DOI]
  6. R. Baskar, "Cancer and radiation therapy : current advances and future directions", Int. J. Med. Sci, 9, pp.193~199 (2012)[DOI]
  7. "What is radiotherapy?" (2020)[URL]
  8. Current Status of Medical Radiation Devices, "Korea Institute of Nuclear Safety", KINS, ~ (2020)
  9. L. Arbea, "Intensitymodulated radiation therapy(IMRT)vs. 3D conformal radiotherapy(3DCRT)in locally advanced rectal cancer(LARC) : dosimetric comparison and clinical implications", Radiat. Oncol, 5, pp.1~9 (2010)[DOI]
  10. E. Bakiu, "Comparison of 3D CRT and IMRT treatment plans", Acta Inf. Med, 21, pp.211~212 (2013)[DOI]
  11. W. V. O. Rodriguez, "Comparison between 3D-CRT and modulated techniques for head-and-neck and breast", AIP Conf. Proc (2018)
  12. H. W. Fischer, "Comparison of activation products and induced dose rates in different high-energy medical linear accelerators", Health Phys, 94 (2008)
  13. T. Kim Tuyet, "Energy and angular distribution of photo-neutrons for 16.6 MeV polarized photon on mediumeheavy targets", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, pp.989~ (2021)
  14. K. Kosako, "Angular distribution of photoneutrons from copper and tungsten targets bombarded by 18, 28, and 38 MeV electrons", J. Nucl. Sci. Technol, 48, pp.227~236 (2011)
  15. A. Naseri, "A review on photoneutrons characteristics in radiation therapy with high-energy photon beams", Rep. Practical Oncol. Radiother, 15, pp.138~144 (2010)
  16. L. Montgomery, "The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator", Med. Phys, 45, pp.4711~4719 (2018)
  17. Management of Radioactive Waste from the Use of Radionuclides in Medicine, "INTERNATIONAL ATOMIC ENERGY AGENCY", IAEA, ~, pp.IAEA-TECDOCd1183 (2000)
  18. Kjeld J. Olsen, "Neutron Contamination from Medical Electron Accelerators (NCRP Report No. 79)", Medical Physics, 13(6), pp.968~969 (1986), Wiley[DOI]
  19. D. Y. Lee, "Assessment of human exposure doses received by activation of medical linear accelerator components", J. Instrum, 12, pp.P08022~ (2017)[DOI]
  20. E. Waller, "Preliminary determination of activation products for a varian truebeam linear accelerator", Health Phys, 113, pp.227~233 (2017)[DOI]
  21. J. Kwak, "Identification of induced-radioactivity in medical LINAC using a NaI(Tl)-Crystal detector", Prog. Nucl. Sci. Technol, 1, pp.525~528 (2011)[DOI]
  22. H. W. Fischer, "Activation processes in a medical linear accelerator and spatial distribution of activation products", Phys. Med. Biol, 51 (2006)
  23. T. Fujibuchi, "Induced radioactive nuclides of 10-MeV radiotherapy accelerators detected by using a portable HP-Ge survey meter", Radiat. Protect. Dosim, 148, pp.168~173 (2012)[DOI]
  24. P. Weber, "activation of radioisotopes and underground gammaspectrometric analyses", Phys. Med, 41 (2018)[DOI]
  25. S. Morato, "Experimental validation of neutron activation simulation of a varian medical linear accelerator", Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBS (2016), IEEE
  26. S. Vichi, "Activation study of a 15MeV LINAC via Monte Carlo simulations", Radiat. Phys. Chem, 172, pp.108758~ (2020)[DOI]
  27. B. Juste, "Neutron activation processes simulation in an Elekta medical linear accelerator head", 2014 36th, Annu. Int. Conf. IEEE, pp.3026~3028 (2014)
  28. T. Fujibuchi, "Induced radioactive nuclides of 10-MeV radiotherapy accelerators detected by using a portable HP-Ge survey meter", Radiat. Protect. Dosim, 148, pp.168~173 (2012)
  29. K. Shida, "Evaluating photonuclear activation for clearance of decommissioned medical linear accelerators", Igaku Butsuri, 31, pp.33~39 (2011)
  30. T. Hayakawa, "Half-life of 184Re populated by photodisintegration reaction with Laser Compton scattering g-rays at NewSUBARU", Int. Conf. Nucl. Data Sci. Technol, pp.73~76 (2007)
  31. N. Młynczyk, "Innovatory production of radioisotopes 117mSn, 186Re and 188Re for laboratory tests and the future application in nuclear medicine", Acta Phys. Pol. B, 51, pp.867~872 (2020)
  32. "Conditional clearance levels for the disposal, recycling and reuse of activated medical accelerator components" (2018)[URL]
  33. "Elekta Medical Linear Accelerator Product Disposal Information" (2019), Technical Publication, ELEKTA Limited
  34. Joint Working Group with Organizations Such as Medical Related Society on Clearance and Radioactive Material, "Society standard on radioactivation management of radiation therapy devices", ~ (2014)

관련 논문AI추천

이 간행물의 다른 논문 (21건)