본문 바로가기
KERD
논문KCI 등재

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

The Korea retrospective dosimetry (KREDOS)–electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose– response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Abstract

The Korea retrospective dosimetry (KREDOS)–electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose– response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

참고문헌 (19)

  1. Use of Electron Paramagnetic Resonance Dosimetry with Tooth Enamel for Retrospective Dose Assessment, "IAEA", International Arts and Entertainment Alliance, ~, pp.IAEA-TECDOC-1331 (2002)
  2. F.C.M. Driessens, "Biominerals", pp.428~ (1990), CRC Press
  3. L.M. de Oliveira, "Energy Dependence of EPR Signal in Synthetic and Biological Hydroxyapatite Irradiated with Photons", Radiation Protection Dosimetry, 84(1), pp.511~514 (1999), Oxford University Press (OUP)[DOI]
  4. I.P. Vorona, "Evidence of annealing-induced transformation of CO2- radicals in irradiated tooth enamel", Radiation Measurements, 41(5), pp.577~581 (2006), Elsevier BV[DOI]
  5. D.U. Schramm, "Electron spin resonance (ESR) studies of CO2- radicals in irradiated A and B-type carbonate-containing apatites", Applied Radiation and Isotopes, 52(5), pp.1085~1091 (2000), Elsevier BV[DOI]
  6. Ye Liu, "Study of new practical ESR dosimeter based on carbonated hydroxyapatite and its dosimetric properties", PLOS ONE, 13(5), pp.e0197953~ (2018), Public Library of Science (PLoS)[DOI]
  7. J.A.F. Gamelas, "Surface properties of carbonated and non-carbonated hydroxyapatites obtained after bone calcination at different temperatures", Colloids and Surfaces A: Physicochemical and Engineering Aspects, 478, pp.62~70 (2015), Elsevier BV[DOI]
  8. N. Hajiloo, "Gamma-irradiated EPR response of nano-structure hydroxyapatite synthesised via hydrolysis method", Radiation Protection Dosimetry, 148(4), pp.487~491 (2011), Oxford University Press (OUP)[DOI]
  9. B. Baghalzadeh, "Gamma irradiated electron paramagnetic resonance response of carbonate ion implanted hydroxyapatite", Nucl. Technol. Radiat, 28, pp.260~264 (2013)
  10. 박병룡, "The first KREDOS-EPR intercomparison exercise using alanine pellet dosimeter in South Korea", Nuclear Engineering and Technology, 52(10), pp.2379~2386 (2020), 한국원자력학회[DOI]
  11. ISO, "Standard Practice for Calibration of Routine Dosimetry Systems for Radiation Processing", ASTM Standard 51261, ~ (2013)
  12. Michael E. Zorn, "Weighted Least-Squares Approach To Calculating Limits of Detection and Quantification by Modeling Variability as a Function of Concentration", Analytical Chemistry, 69(15), pp.3069~3075 (1997), American Chemical Society (ACS)[DOI]
  13. ISO, "Standard ISO 11929-7Determination of the Detection Limit and Decision Threshold for Ionizing Radiation Measurements-Part 7" (1998), Fundamentals and General Applications
  14. P. Fattibene, "The 4th international comparison on EPR dosimetry with tooth enamel", Radiation Measurements, 46(9), pp.765~771 (2011), Elsevier BV[DOI]
  15. L.A. Currie, "Detection and quantification limits: basic concepts, international harmonization, and outstanding (“low-level”) issues", Applied Radiation and Isotopes, 61(2-3), pp.145~149 (2004), Elsevier BV[DOI]
  16. ISO, "Radiological Protection—Minimum Criteria for Electron Paramagnetic Resonance (EPR) Spectroscopy for Retrospective Dosimetry of Ionizing Radiation—Part 1: General Principles ISO 13304", ~ (2020)
  17. "ISO", ASTMStatistical Methods for Use in Proficiency Testing by Inter Laboratory Comparison 3528, 2015
  18. Metrology (JCGM) International Vocabulary of Metrology—Basic and General Concepts and Associated Terms (VIM); Technical Report, "Joint Committee for Guides", JCGM, 200~ (2012)
  19. International Organization for Standardization, "Conformity Assessment General Requirements for Proficiency Testing", ISO, 2010

관련 논문AI추천

X-band EPR dosimetry using minimum mass of tooth enamel for use in radiological accidents김용균, 김재석, 김한성, 김효진, 박병룡, 어인모, 유재룡, 장원일, 조민수한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제1호Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident김용균, 김재석, 박병룡, 장원일, 조민수한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제1호Reference dosimetry for inter-laboratory comparison on retrospective dosimetry techniques in realistic field irradiation experiment using 192Ir김민채, 김영수, 김한성, 김형택, 유형준, 이정일, 이정태, 이한진, 이현석, 최유미한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제7호유리선량계 특성평가 및 판독 보정인자에 대한 불확도 평가안현, 강영록, 계용욱, 김효진, 목성윤대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제3호Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity김현, 김용균, 김재석, 박병룡, 유재룡, 장성재, 장원일, 장인수, 조규석, 하위호한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제2호Assessment Results to Determine Proficiency in Irradiation Procedures이윤종(사)한국방사선산업학회 · 방사선산업학회지2024 · 제18권 제4호

이 간행물의 다른 논문 (39건)